Validation of non-destructive testing methods is necessary to create a common basis where different systems can be compared and their applications and limitations be identified. This can be achieved through comparing the measurements taken by several systems used for a common diagnostic purpose under practical but controlled testing conditions. Well-designed small and large laboratory or field specimens promise such conditions.
The special concrete specimen (LCS) at BAM was constructed for validation purposes, in particular, to be used for evaluating the performance of echo methods. The thickness of the specimen is varying and it contains carefully designed built-in faults, such as voids, honeycombs and tendon ducts with various degrees of grouting defects. Since the geometry and condition of the defects are known, it can be used to compare the performance of radar, ultrasonic, impact-echo. The research was conducted within the Research group FOR384, sponsored by the German Research Society DFG.
Air-coupled ultrasound sensors have advantages over contact ultrasound sensors when a sample should not become contaminated or influenced by the couplant or the measurement has to be a fast and automated inline process. Thereby, air-coupled transducers must emit high-energy pulses due to the low air-to-solid power transmission ratios (10−3 to 10−8). Currently used resonant transducers trade bandwidth—a prerequisite for material parameter analysis—against pulse energy. Here we show that a combination of a non-resonant ultrasound emitter and a non-resonant detector enables the generation and detection of pulses that are both high in amplitude (130 dB) and bandwidth (2 µs pulse width). We further show an initial application: the detection of reflections inside of a carbon fiber reinforced plastic plate with thicknesses between 1.7 mm and 10 mm. As the sensors work contact-free, the time of flight and the period of the in-plate reflections are independent parameters. Hence, a variation of ultrasound velocity is distinguishable from a variation of plate thickness and both properties are determined simultaneously. The sensor combination is likely to find numerous industrial applications necessitating high automation capacity and opens possibilities for air-coupled, single-side ultrasonic inspection.