Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (30)
- Vortrag (26)
- Beitrag zu einem Tagungsband (8)
- Posterpräsentation (3)
- Buchkapitel (2)
- Beitrag zu einem Sammelband (1)
- Sonstiges (1)
- Forschungsbericht (1)
Schlagworte
- Neutron radiography (15)
- Hydrogen (10)
- Neutron imaging (10)
- Diffusion (8)
- LIBS (8)
- Welding (8)
- Hydrogen embrittlement (7)
- In situ measurement (6)
- Neutron tomography (6)
- Hydrogen diffusion (5)
- Radiography (5)
- Steel (5)
- Hydrogen assisted cracking (4)
- TIG welding (4)
- X-ray refraction (4)
- Bragg-edge imaging (3)
- Duplex stainless steel (3)
- Duplex stainless steels (3)
- In-situ (3)
- Melt (3)
- Neutron (3)
- Alloy (2)
- Austenite-to-martensite transformation (2)
- Austenitic stainless steels (2)
- Blister (2)
- Capillary (2)
- Chemical composition (2)
- Computed tomography (2)
- Debye-Waller-Faktor (2)
- Debye–Waller factor (2)
- Gas tungsten arc welding (GTAW) (2)
- Hot cracking (2)
- In situ (2)
- Iron (2)
- Liquid alloys (2)
- Low transformation temperature (LTT) steel (2)
- Metal (2)
- Semiconductor (2)
- Shear cell (2)
- Synchrotron (2)
- Synchrotron radiation (2)
- Tomography (2)
- WRC 1992 diagram (2)
- Wasserstoff (2)
- 2101 duplex stainless steel (1)
- Aluminium (1)
- Aluminium alloy (1)
- Aluminium alloys (1)
- Aluminium-alloys (1)
- Analyser based imaging (1)
- Analyser-based imaging (1)
- Austenitic (1)
- Austenitic stainless steel (1)
- Backlight (1)
- Bragg-edge neutron 2D imaging (BENI) (1)
- CT (1)
- Carrier gas hot extraction (1)
- Chemical analysis (1)
- Chemical interdiffusion (1)
- Columnar and equiaxed structures (1)
- Component design (1)
- Computed tomography (CT) (1)
- Convection (1)
- Crack criterion (1)
- Crystallographic texture control (1)
- Darken (1)
- Dduplex stainless steel (1)
- Debye waller factor (1)
- Debys-Waller-Factor (1)
- Dendritic growth (1)
- Diffusible hydrogen (1)
- EDS (1)
- ESA (1)
- Electron backscatter diffraction (EBSD) (1)
- Evaporation (1)
- External load test (1)
- Ferritic stainless steel (1)
- GMAW (1)
- GTA welding (1)
- GTAW (1)
- Global databases (1)
- Grain growth (1)
- Hot crack (1)
- Hydrogen assisted cracking (HAC) (1)
- Hydrogen effusion (1)
- Hydrogen embrittlement (HE) (1)
- Hydrogen measurement (1)
- ICME (1)
- IN718 PBF-LB/M (1)
- Imaging (1)
- LIBS TIG welding (1)
- Laminography (1)
- M-ERA.net (1)
- Mass transfer (1)
- Materials in space (1)
- Materials simulation (1)
- Materialschaedigung (1)
- Materialschädigung (1)
- Measurement (1)
- Metal additive manufacturing (MAM) (1)
- Metal vapor (1)
- Microcracking (1)
- Microgravity (1)
- Microstructure (1)
- Modified Varestraint Transvarestraint (1)
- Neutron Imaging (1)
- Neutronen (1)
- Nickel (1)
- Nickel alloys (1)
- Phase transformation (1)
- Real-time operation (1)
- Refraction (1)
- Röntgenradiographie (1)
- Röntgenrefraktion (1)
- Scattering (1)
- Snergiedispersive Röntgendiffraktion (1)
- Solidification cracking (1)
- Stainless steel (1)
- Stainless steels (1)
- Supermartensitic steel (1)
- Supermatensitischer Stahl (1)
- Susceptibility (1)
- TIG (1)
- Temperature distribution determination (1)
- Tomographie (1)
- Topical team (1)
- VAMAS (1)
- WMRIF (1)
- Wasserstoffdegradation (1)
- Wasserstoffunterstützte Rissbildung (1)
- Wasserstoffversprödung (1)
- X-ray apparatus (1)
- X-ray imaging (1)
- X-ray radiography (1)
- XRF (1)
- Zugversuch (1)
- cold neutrons (1)
- iron embrittlement (1)
- neutron imaging (1)
- neutron instrumentation (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (26)
The purpose of the present study is to show the feasibility of examining hydrogen desorption in technical iron samples using neutron radiography at the ANTARES facility of the FRM II research reactor, Technische Universität München. It has been shown that this method is appropriate for in situ determination of hydrogen Desorption for concentrations as low as 20 ppmH. Experiments were carried out in the temperature range from room temperature up to 260 °C. Measurement was based on direct comparison between electrochemically hydrogen-loaded iron samples and hydrogen-free reference samples at the same temperature.
This enables the determination of hydrogen concentration as a function of time and temperature. Ex situ carrier gas hot extraction experiments using the same temperature–time profiles as the neutron radiography experiments have been used to calibrate the greyscale values of the radiographs to defined hydrogen concentrations. It can be stated that hydrogen desorption correlates with sample temperature.
The purpose of the present study was to show the feasibility of measuring hydrogen effusion in austenitic stainless steel (1.4301) using neutron radiography at the facility ANTARES of the research reactor FRM II of the Technische Universität München. This method is appropriate to measure in-situ hydrogen effusion for hydrogen concentrations as small as 20 ppmH. Experiments were carried out in the temperature range from room temperature up to 533 K. The measurement principle is based on the parallel comparison of electrochemically hydrogen charged specimen with hydrogen-free reference specimen at the same temperature. This allows the determination of the hydrogen concentration in the specimens as a function of time and temperature. Separate hot carrier gas extraction experiments using the same temperature–time profiles as the radiography experiments have been used to calibrate the grey values of the neutron transmission images into hydrogen concentrations. It can be stated that the hydrogen effusion correlates with the specimen temperature.
In situ crack detection in the mushy zone and the solid weld of a gas tungsten arc (GTA) weld using X-ray imaging during welding is a new research area for NDT inspection. Usually, NDT flaw detection is done after the complete solidification of the weld seam. In this paper, we present the use of real-time radiography with a minifocus X-ray source (YXLON X-ray tube Y.TU 225-D04) and a 75μm pixel size digital detector array (Dexela 1512) for the acquisition of 2D radiographic images by a sequence of exposures with time intervals of 80 ms for hot crack detection during single pass bead-on-plate GTA welding of 3 mm thick plates of aluminium alloy AlMgSi (6060). An analysis of the crack distribution in the weld sample is conducted from the acquired 2D radiographs and its corresponding 3D volumetric reconstruction achieved by linear coplanar digital laminography.
This in situ approach opens new possibilities in the field of hot crack research by having the direct information of both the crack initiation and growth and its correlation to the welding parameters.
Gravity has significant effects on alloy solidification, primarily due to thermosolutal convection and solid phase buoyancy. Since 2004, the European Space Agency has been supporting investigation of these effects by promoting in situ X-ray monitoring of the solidification of aluminium alloys on microgravity platforms, on earth, and in periodically varying g conditions. The first microgravity experiment-investigating foaming of liquid metals - was performed on board a sounding rocket, in 2008. In 2012 the first ever X-ray-monitored solidification of a fully dense metallic alloy in space was achieved: the focus was columnar solidification of an Al-Cu alloy. This was followed in 2015 by a similar experiment, investigating equiaxed solidification. Ground reference experiments were completed in all cases. In addition, experiments have been performed on board parabolic flights-where the effects of varying gravity have been studied. We review here the technical and scientific progress to date, and outline future perspectives.
Hydrogen embrittlement (HE) is a widely known phenomenon and under investigation already for more than a century. This phenomenon, though thoroughly studied, is not yet completely understood, and so far, there are several suggested mechanisms that try to explain the occurrence of HE. One important factor of understanding the HE phenomenon and predicting hydrogen-assisted failure is the descent knowledge about the hydrogen transport behaviour in the material. Neutron radiography is a proven method for tracking hydrogen diffusion and it was applied successfully in various research studies. In the presented study, we examined the hydrogen effusion behaviour in duplex stainless steel by means of neutron radiography and calculated the effective diffusion coefficient from the obtained transmission images.
Neutron Bragg-edge imaging was applied for the visualization of a γ-Austenite to α'-martensite phase transformation. In the present study, a super martensitic
stainless steel sample was heated until complete austenitization and was subsequently cooled down to room temperature. The martensitic phase Transformation started at Ms = 190 °C. Using a monochromatic neutron beam with λ = 0.390 nm, the transmitted intensity was significantly reduced during cooling below Ms, since the emerging martensitic phase has a higher attenuation coefficient than the austenitic phase at this wavelength. The phase Transformation process was visualized by filming the transmission images from a scintillator screen with a CCD camera with a temporal resolution of 30 s and a spatial
resolution of 100 µm.
A long list of criteria determining the hot cracking susceptibility already exists. A main influence on solidification cracking can result from the design of the welded construction, i.e. from the influence of external loads. Using the Controlled Tensile Weldability (CTW) test, an external load hot cracking test, the influence of constant pre-load and different extension rates on the solidification cracking behavior of GTA (Gas Tungsten Arc) welds in an austenitic (AISI 309) and a ferritic (AISI 441) steel were investigated. Compared to specimens welded allowing free shrinkage and welded with an applied constant tensile pre-load, the specimens welded during the application of increasing tensile load show solidification cracks. In the weld seams, a characteristic angle α between the predominantly columnar grains and the fusion line can be observed. Specimens showing solidification cracks show a significantly larger angle α compared to the crack-free specimens. Based on these observations, the characteristic angle α is proposed as a new hot cracking criterion.