Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (20)
- Vortrag (17)
- Posterpräsentation (10)
- Zeitschriftenartikel (8)
- Beitrag zu einem Sammelband (3)
- Buchkapitel (1)
Schlagworte
- Drop test (6)
- Behälterzulassung (2)
- Bending (2)
- Compressive strength (2)
- DUCON® (2)
- Digital image correlation (2)
- Ductility (2)
- E-modulus (2)
- Fotogrammetrie (2)
- Grating method (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (17)
The effect of the wall thickness variation of blow-moulded bodies made of high-density polyethylene on an internal pressure test after prestoring the packaging with standard liquids was evaluated in experiments and simulations. The objects of the investigation were jerrycans used for the transportation and storage of dangerous goods.
The wall thickness was determined using two alternative methods to the magnetostatic measurement. These alternative methods are used for research purpose to get a volumetric model of the jerrycan wall as a geometric model for the simulation. The comparison of the experiments and the simulations of the internal pressure test were performed using the digital image correlation method. The integral strain and deformation of the whole jerrycan was detected by measuring the total mass of the jerrycan being filled with water during the internal pressure test. This is a suitable alternative to the optical measurements of local deformation by the digital image correlation method. Prestorage at 40°C without the influence of chemicals strengthens the jerrycan, whereas the swelling effect of butyl acetate and hydrocarbon mixture softens the jerrycan. The comparison with the experiment is necessary to verify the accuracy of the simulation. It shows that the deformation can be simulated more precisely by using the actual measured geometry. The weakening of the high-density polyethylene caused by a hydrocarbon mixture can be simulated using the Arrhenius equation. The aim of the simulation was to discover whether it is possible to use specimens to predict the behaviour of a packaging both after the influence of standard liquids.
A unique testing facility (KALFOS) using ESPI (electronic speckle pattern interferometery) as a referencing method has been realized for the characterisation of the strain transfer process from a component under load into surface applied fibre Bragg grating based strain sensors. The strain transfer mechanism can be described experimentally, while matching specific measurement requirements and environmental conditions.
Zur Verformungsanalyse einer 24 m langen, extern vorgespannten aber aufgrund von drei Stützfundamenten zwei Teilbereiche bildenden monolithischen Stahlbeton-Modellbrücke wurde ein komplett erfassendes stereo-optisches Messverfahren eingesetzt. Das Verfahren, dessen Kalibrierung sowie die experimentellen Randbedingungen werden beschrieben. Die im Fall quasistatischer Belastungsänderung gemessenen Verformungen zeigten signifikant messbare Verschiebungswerte im unteren mm-Bereich. Bei stochastischer Schwingungsanregung mit einem Shaker können in diesem für das Verfahren großen Messbereich die ersten drei resonanten Betriebsschwingformen bestimmt werden. Die realitätsnah kleinen Schwingungsamplituden sowie die begrenzte Koordinatenauflösung des bei 464 Hz Bild-folgefrequenz mit 4000 x 370 Bildpunkten betriebenen 12MP-Kamerapaares wirken sich limitierend aus. Beispielhafte Animationen zeigen die Verformungen der Modellbrücke unter Laständerung.
Bending beams and slabs are typical examples for structural elements used for reinforced concrete structures such as bridge girders, T-beams and bridge decks. Their strength related failure modes at maximum loading can be divided into bending and shear failure. The failure of beams loaded in bending can occur with or without indication. Therefore, conventional design concepts aim on failure modes with sufficient indication (e.g. large deflections or cracks), as it occurs in the case of secondary flexural compression failure. These indicating factors can also be used for Structural Health Monitoring (SHM) of civil infrastructure systems (e.g. bridges) to identify structural changes. In this context, non-destructive testing (NDT) methods offer different techniques for measuring deflections or crack formation and opening. However, profound knowledge on the determining failure modes of bending beams and their detection by NDT methods is required for the reliable application of SHM. Different NDT methods have been used in this study for analysing the load-bearing behaviour of a reinforced concrete beam in bending. The different measuring techniques are briefly described and their applicability is discussed by means of experimental results. For this purpose, the load-bearing behaviour of a reinforced concrete beam having a span of 2.75 m was investigated in a four-point bending flexural test at laboratory scale. The focus is on the characterization of determining failure modes by optical NDT and the comparison with classical measuring techniques (e.g. deformation measurements by displacement transducers). The bending beam was equipped with two single-mode (SM) sensor fibres. One fibre served as Distributed Optical Fibre Sensor (DOFS), whereas the other fibre contained Fibre Bragg Grating (FBG) sensors. In addition, optical deformation measurements using Digital Image Correlation (DIC) and Stereophotogrammetry (SP) were conducted.
Damage mechanisms analysis of reinforced concrete beams in bending using non-destructive testing
(2019)
Beams that are loaded in transverse direction are one of the main structural elements used in reinforced concrete structures. Bending beams are used, for example, in bridge girders or joists. The strength related failure modes at maximum loading can be divided into bending and shear failure that could occur with or without indication. Conventional design concepts used in practice for designing structural elements subjected to bending aim at failure modes with sufficient indication (e.g. large deflections or cracks), as it occurs in the case of secondary flexure-compression-failure. These indicators can also be used to identify structural changes of civil infrastructure systems (e.g. bridges) using non-destructive testing methods for Structural Health Monitoring (SHM). However, profound knowledge on the determining failure modes of bending beams is required for the reliable application of structural health monitoring. Therefore, resulting effects of different thermal and mechanical loads on the response of a structure are investigated by means of a bridge demonstrator. The results of this investigation are used for developing a monitoring system. Different non-destructive testing (NDT) methods have been used for analyzing the deformation behavior of a reinforced concrete beam in bending. The suitability of the different measuring techniques will be discussed by means of the obtained experimental results. For this purpose, the deformation behavior of a reinforced concrete beam having a span of 2.75 m was investigated in a four-point bending flexural test at laboratory scale. The focus is on the characterization of determining failure modes by the NDT methods and the comparison with classical measuring techniques (e.g. deformation measurements by displacement transducers). The bending tests have been accompanied by Acoustic Emission analysis (AE), optical deformation measurements using Stereophotogrammetry (SP) and Digital Image Correlation (DIC). The conducted tests have shown that the three-dimensional detection of deformations and resulting strains with optical techniques is beneficial for analyzing the damage mechanism of loaded structures and related crack formation and propagation. Optical techniques can be supplemented by acoustic emission testing which gives detailed information on crack formation and progressing damage. The combination of both techniques offers the application as efficient monitoring system for larger structures.