Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (80)
- Zeitschriftenartikel (78)
- Posterpräsentation (25)
- Beitrag zu einem Tagungsband (3)
- Buchkapitel (2)
- Preprint (1)
Schlagworte
- LIBS (50)
- Laser induced plasma (45)
- Plasma modeling (38)
- Plasma diagnostics (27)
- Laser ablation (13)
- Plasma chemistry (13)
- Emission spectroscopy (11)
- Surface coating (11)
- Laser induced plasma deposition (9)
- Laser-induced breakdown spectroscopy (9)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (86)
- 1.9 Chemische und optische Sensorik (50)
- 1.3 Instrumentelle Analytik (36)
- 8 Zerstörungsfreie Prüfung (9)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (7)
- 8.3 Thermografische Verfahren (2)
- 9 Komponentensicherheit (2)
- 9.3 Schweißtechnische Fertigungsverfahren (2)
- 1.4 Prozessanalytik (1)
- 5 Werkstofftechnik (1)
Eingeladener Vortrag
- nein (80)
The potential of a diode pumped solid state (DPSS) laser for laser induced breakdown spectroscopy (LIBS) and Raman spectroscopy was investigated. The DPSS laser operating at repetition rates of 1 Hz–200 kHz, pulse energy of ~1 mJ, and pulse duration of ~20 ns was added to a conventional LIBS system equipped with the flashlamp-pumped Nd:YAG laser (10 Hz, 400 mJ, 6 ns) to directly compare the two laser systems. Despite the lower mass ablated per laser pulse (~several nanograms) and a weaker plasma, the total mass ablated per measurement interval (~1 s) and total emission signal were significantly higher than those obtained with the flashlamp pumped Nd:YAG laser. This resulted in the improved signal-to-noise ratio and better limits of detection (LOD). The best LODs were obtained for Cu, Cr and Ni in ultrapure standard iron samples, 0.7 ppm, 1 ppm and 5 ppm, correspondingly. The plasma from the DPSS laser was characterized in terms of its radiative properties, temperature, and shockwave propagation speed. The suitability of this laser for LIBS-Raman was demonstrated by mapping the elemental and molecular composition of a mineral sample. The results strongly imply that DPSS lasers are the promising source for LIBS, Raman, or combined LIBS-Raman spectroscopy.
Boltzmann Plot and Abel Inversion Methods for Plasma Diagnostics: Implications from Plasma Modeling
(2010)
High repetition rate laser-induced breakdown spectroscopy using acousto-optically gated detection
(2014)
This contribution introduces a new type of setup for fast sample analysis using laser-induced breakdown spectroscopy (LIBS). The novel design combines a high repetition rate laser (up to 50 kHz) as excitation source and an acousto-optical modulator (AOM) as a fast switch for temporally gating the detection of the emitted light. The plasma radiation is led through the active medium of the AOM where it is diffracted on the transient ultrasonic Bragg grid. The diffracted radiation is detected by a compact Czerny-Turner spectrometer equipped with a CCD line detector. Utilizing the new combination of high repetition rate lasers and AOM gated detection, rapid measurements with total integration times of only 10 ms resulted in a limit of detection (LOD) of 0.13 wt.% for magnesium in aluminum alloys. This short integration time corresponds to 100 analyses/s. Temporal gating of LIP radiation results in improved LODs and consecutively higher sensitivity of the LIBS setup. Therefore, an AOM could be beneficially utilized to temporally detect plasmas induced by high repetition rate lasers. The AOM in combination with miniaturized Czerny-Turner spectrometers equipped with CCD line detectors and small footprint diode pumped solid state lasers results in temporally gateable compact LIBS setups.
In this work, the potential of laser-induced breakdown spectroscopy (LIBS) for discrimination and analysis of geological materials was examined. The research was focused on classification of mineral ores using their LIBS spectra prior to quantitative determination of copper. Quantitative analysis is not a trivial task in LIBS measurement because intensities of emission lines in laser-induced plasmas (LIP) are strongly affected by the sample matrix (matrix effect). To circumvent this effect, typically matrix-matched standards are used to obtain matrix-dependent calibration curves. If the sample set consists of a mixture of different matrices, even in this approach, the corresponding matrix has to be known prior to the downstream data analysis. For this categorization, the multielemental character of LIBS spectra can be of help. In this contribution, a principal component analysis (PCA) was employed on the measured data set to discriminate individual rocks as individual matrices against each other according to their overall elemental composition. Twenty-seven igneous rock samples were analyzed in the form of fine dust, classified and subsequently quantitatively analyzed. Two different LIBS setups in two laboratories were used to prove the reproducibility of classification and quantification. A superposition of partial calibration plots constructed from the individual clustered data displayed a large improvement in precision and accuracy compared to the calibration plot constructed from all ore samples. The classification of mineral samples with complex matrices can thus be recommended prior to LIBS system calibration and quantitative analysis.
The improved Monte-Carlo (MC) method for standard-less analysis in laser induced breakdown spectroscopy (LIBS) is presented. Concentrations in MC LIBS are found by fitting model-generated synthetic spectra to experimental spectra. The current version of MC LIBS is based on the graphic processing unit (GPU) computation and reduces the analysis time down to several seconds per spectrum/sample. The previous version of MC LIBS which was based on the central processing unit (CPU) computation requested unacceptably long analysis times of 10's minutes per spectrum/sample. The reduction of the computational time is achieved through the massively parallel computing on the GPU which embeds thousands of co-processors. It is shown that the number of iterations on the GPU exceeds that on the CPU by a factor > 1000 for the 5-dimentional parameter space and yet requires > 10-fold shorter computational time. The improved GPU-MC LIBS outperforms the CPU-MS LIBS in terms of accuracy, precision, and analysis time. The performance is tested on LIBS-spectra obtained from pelletized powders of metal oxides consisting of CaO, Fe2O3, MgO, and TiO2 that simulated by-products of steel industry, steel slags. It is demonstrated that GPU-based MC LIBS is capable of rapid multi-element analysis with relative error between 1 and 10's percent that is sufficient for industrial applications (e.g. steel slag analysis). The results of the improved GPU-based MC LIBS are positively compared to that of the CPU-based MC LIBS as well as to the results of the standard calibration-free (CF) LIBS based on the Boltzmann plot method.
The equation of state for plasmas containing negative atomic and molecular ions (anions) is modeled. The model is based on the assumption that all ionization processes and chemical reactions are at local thermal equilibrium and the Coulomb interaction in the plasma is described by the Debye–Hu¨ckel theory. In particular, the equation of state is obtained for plasmas containing the elements Ca, Cl, C, Si, N, and Ar. The equilibrium reaction constants are calculated using the latest experimental and ab initio data of spectroscopic constants for the molecules CaCl2, CaCl, Cl2, N2, C2, Si2 , CN, SiN, SiC, and their positive and negative ions. The model is applied to laserinduced plasmas (LIPs) by including the equation of state into a fluid dynamic numerical model based on the Navier–Stokes equations describing an expansion of LIP plumes into an ambient gas as a reactive viscous flow with radiative losses. In particular, the formation of anions Cl-, C-, Si-, Cl2, Si2, C2 , CN-, SiC-, and SiN- in LIPs is investigated in detail.