Analysis of morphology and composition with computed tomography exemplified at porous asphalt
(2007)
The in vivo effects of coating titanium implants with organic extracellular matrix molecules were examined in the sheep tibia. Titanium screws (5.0 mm) were coated with type I collagen (Ti/Coll) or type I collagen and chondroitin sulfate (Ti/Coll/CS) by biomimetic fibrillogenesis. Uncoated screws (Ti) and screws coated with hydroxyapatite (Ti/HA) served as control. Six adult female sheep received one screw of each type to stabilize a midshaft tibial fracture with external fixation. Four cylindrical implants of 4-mm outer diameter and 3.3-mm inner diameter with the same coatings were inserted into the tibial head. No pin track infections were seen at the time of implant retrieval 6 weeks after implantation. Extraction torque was greater for Ti/HA (1181 Nmm) and Ti/Coll/CS (1088 Nmm) compared to Ti/Coll (900 Nmm) and Ti (904 Nmm) [N.S.]. Newly formed bone was noted around all coated screws within the medullary cavity. Macrophage and osteoclast activity was significantly reduced around Ti/Coll/CS in both types of implants compared to uncoated controls (p < 0.05). Osteoblast activity was significantly increased around loaded Ti/Coll and Ti/Coll/CS screws compared to uncoated Ti screws (p < 0.05). Microtomographic evaluation (SRµCT) revealed no significant differences in new bone formation around the unloaded tibial head implants.Coating of external fixation devices with of type I collagen and chondroitin sulfate appears to have similar effects with respect to stability and bone healing as HA but with less osteoclast activity. These findings were more pronounced under loaded than unloaded conditions in the sheeptibia.
Carrying out dimensional measurements by CT means assessing coordinates in space. CT must therefore be treated as a coordinate measuring technique similar to optical or tactile Coordinate Measuring Machines (CMMs). The well-established standards and guidelines for the acceptance- and verificationtesting of CMMs require the use of calibrated reference standards to achieve measurement machine characteristics.
Hence, transferring these concepts from coordinate metrology to CT, a dedicated CT-specific reference standard was designed, manufactured and calibrated using a tactile CMM. For comparison purposes, a CAD model was created by reverse engineering using the calibration data. The calibrated model was fed into a virtual CT and the measurement process was simulated. The reference standard was measured by micro-CT.
By comparing the characteristics of the measurement output of CT and the output gained from simulation, the influences of measurement artefacts can be judged, for the first time, in analogy to existing Guidelines of coordinate metrology.