For plastic packaging, both weathering and Chemical exposure are well known, slow-going damaging scenarios, which themselves are sufficiently covered in relevant transport regulations, but treated there separately.
In previous work, it has been shown that both can act synergistically, resulting in leakage failure after only six month outdoor exposure in Berlin/Germany.
A new weathering device is presented which enables combined exposure of whole components under controlled laboratory conditions. This device allows exposure of an up to 60 litres Container which is filled with dangerous liquid. By using a collecting drip pan and an extractor hood, safety is guaranteed, also in case of leakage failure. Irradiance homogeneity is realized by rotating the Container between two opposed lamp fields consisting of vertically arranged UV fluorescent lamps. Using UVA 340nm lamps with spectral emission mainly between 290 and 380 nm, the short wave ränge of global solar radiation is simulated very precisely. UV irradiance is constantly 60 W/m2, thus it is a bit higher than maximum global solar radiation in the considered UV ränge. Radiation heating is knowingly excluded, avoiding heat production that potentially could be critical for included dangerous liquids.
Adjusting constant temperature of 40 °C, chosen conditions aim at worst case outdoor conditions, for uncolored Containers.
Ingenieurbauwerke wie Brücken, hoch beanspruchte Verkehrsflächen oder auch Hochhäuser und deren Bauwerksteile wie z.B. Hochhausfassaden werden aus technischen und ästhetischen Gründen durch Fugen in Einzelabschnitte unterteilt. Zur Sicherstellung der Gebrauchsfähigkeit und zum Schutz des Gesamtbauwerks, aber in zunehmendem Maße auch zur statisch-konstruktiven Anbindung der Bauwerksteile, werden diese Fugenspalte in aller Regel durch spezielle Fugenfüllsysteme verschlossen. Aufgrund der hohen Sicherheitsrelevanz bei Fugenfüllungen im Glasfassadenbau fordert das Baurecht auch bei diesen Bauprodukten als Voraussetzung für die baupraktische Verwendbarkeit neben dem Nachweis der Funktionsfähigkeit auch den Nachweis der Dauerhaftigkeit. Da die hierfür bekannten Nachweismethoden zur Dauerhaftigkeit keine allgemeine Zulassungsakzeptanz finden, kann das ästhetische, bauphysikalische und ökonomische Potential von modernen geklebten Ganzglasfassaden (sogenannte SSG-Fassaden) in der Baupraxis der Bundesrepublik Deutschland derzeit nicht ausgenutzt werden. Grund dafür sind die ungenügend erfassten und in den Bewertungsverfahren simulierten Wechselwirkungen derartiger Baukonstruktionen mit der Umwelt. In diesem Beitrag soll am Beispiel moderner Fugen im Glasfassadenbau (SSG-Fassaden) eine ganzheitliche gebrauchsbezogene Versuchsmethodik zur kontrollierten Ansprache der Funktionsfähigkeit und Dauerhaftigkeit von Fugensystemen unter realitätsnah und reproduzierbar simulierten Umwelteinwirkungen vorgestellt werden. Dazu werden die maßgebenden Umwelteinflüsse und die Quantifizierung der daraus folgenden Beanspruchungen auf derartige Fugensysteme dargestellt. Basierend darauf werden eine repräsentative Beanspruchungsfunktion zur Nachstellung der maßgebenden Umwelteinflüsse und Beanspruchungen auf das System Tragrahmen - Fugenfüllung- Glasscheibe sowie eine geeignete Probendimensionierung abgeleitet. In der Konsequenz werden die Erkenntnisse in den Aufbau einer neuartigen komplexen Versuchseinrichtung überführt. Funktionsprinzip und Leistungsparameter dieser Anlage zur Umweltsimulation werden vorgestellt. Die Möglichkeiten der Systemkennzeichnung werden vorgestellt. Erste Versuchsergebnisse zeigen das Potential der neuartigen Bewertungsmethodik auf, die Kunst der Fuge im Bauwesen gebrauchsorientiert weiter zu entwickeln.
The surface temperature of test specimens exposed to natural and artificial solar radiation are roughly ascertained with black standard thermometers BST and white standard thermometers WST. For the calibration of these thermometers a new European Standard prEN 16465 was published in 2015, describing the well-known contact method and a new contactless method with a pyrometer. It can be confirmed that the temperature calibrations according to the two methods provide different calibration results which are not interchangeable (which is already stated in the scope of this standard). The described contactless method to determine the surface temperature 'under radiation load' results in clearly too high temperatures. This paper tries to highlighting the reasons.
A new irradiation device for the exposure of plastic products is presented. Developed in the BAM division 3.1 "Dangerous Goods Packaging" it can be used for artificial UV irradiation of plastic Containers filled with hazardous liquids.
Present regulations and tests only investigate the exposure effects of UV and of media separately, but as the damaging effect is expected to be synergistic for at least some media, a combined test was looked for.
A chamber of 60 cm by 60 cm base area and 1 m height gives space for up to 40 cm wide objects. Two fluorescent UV lamp arrays are arranged on opposite walls, separated from the chamber by quartz glass panes. By continuously rotating the exposure object by means of a rotary disc that the object is placed on, spatial irradiation homogeneity is achieved over the exposure duration. The spectral irradiance of the chosen UVA 340 nm lamps gives the best match of global solar radiation in the short wavelength ränge. The close arrangement of the UVA lamps (15 each side) results in 60 W m'2 UV irradiance.
Constant temperature is adjusted to typically 40 °C by the control of the fan speed. This temperature is chosen, as it is the required temperature for three week storage of filled polyethylene Containers, for proving Chemical compatibility in the field of dangerous goods. To ensure homogeneity, an interiorfan provides for air circulation.
The aim of the joint project ViPQuali (Virtual Product Qualification) was to describe a components ageing behaviour in a given environment, by numerical simulation.
Having chosen polypropylene (PP) as the material, which does not show sensitivity to moisture, the relevant weathering parameters of the doseresponse functions could be limited to spectral irradiance and temperature.
In artificial irradiation tests, for PP plates of varied stabiliser content, spectral sensitivity as well as temperature dependence of irradiation-caused crack formation was quantified. For that purpose, samples were exposed both to artificial weathering tests at various constant temperatures and to spectrally resolved irradiation. The temperature dependence could be modelled by an Arrhenius fit. For fitting the spectral sensitivity, a plateau function was chosen. Subsequently, the stabiliser content was parameterised and extrapolated.
The formed dose–response functions were incorporated into a Computational Fluid Dynamics (CFD) software program, simulating the environment of a sample within a Phoenix-exposed IP/DP (Instrument Panel/Door Panel box) box, based on sun position and weather conditions, including radiation interactions. Observed local effects as well as the general ageing advance of PP hats are compared with respect to simulation and experiment.
Resulting from this project, for this most simple example of PP of varied stabiliser content, the time to failure can be estimated for each weathering exposure environment with known time-resolved irradiance and temperature conditions.
In order to estimating the amount and kind of emissions from polymeric sporting tracks a laboratory test was developed in BAM that combines artificial weathering and subsequent batch and column tests [1, 2, 3]. The goal consisted in nvestigating a possible change of emissions into soil and groundwater of a new sporting ground as a function of ageing and egradation of the system. At various stages of the weathering, the samples were removed and subjected to especially designed column extraction tests for the solid samples. Both these extracts and the accumulated rainwater run-off of the weathering device were subjected to analytical tests of their ingredients. The overall aim of the test consisted in developing ontrollable, reproducible, and standardisable conditions and methods of investigation that would allow an estimation of the emissions in the course of outdoor application of about five years.