Filtern
Dokumenttyp
- Posterpräsentation (11)
- Zeitschriftenartikel (5)
- Vortrag (4)
- Beitrag zu einem Tagungsband (3)
- Buchkapitel (1)
- Preprint (1)
- Forschungsbericht (1)
Sprache
- Englisch (22)
- Deutsch (3)
- Mehrsprachig (1)
Referierte Publikation
- nein (26) (entfernen)
Schlagworte
- Fluorescence (8)
- Air quality (3)
- Air quality monitoring (3)
- Ammonia gas sensor (3)
- Environment (3)
- Spectroscopy (3)
- Standard gas generator (3)
- Ammonia (2)
- Embedded sensor (2)
- Fluorescence sensors (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (12)
- 1.9 Chemische und optische Sensorik (12)
- 8 Zerstörungsfreie Prüfung (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 1.5 Proteinanalytik (1)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 6 Materialchemie (1)
- 6.3 Strukturanalytik (1)
Eingeladener Vortrag
- nein (4)
Um verlässliche Methoden für die medizinische Diagnostik und Umweltanalytik zu entwickeln sowie Zellen zu kultivieren, ist staub- bzw. keimfreies Arbeiten in einem Reinraum erforderlich. Aber was ist ein Reinraum? Viele stellen sich hier sterile Räume, keine Fenster und Personen in weißen Anzügen und Schutzmaske vor. Hier können die Besucher einen Blick hinter die Kulissen werfen und erfahren, was die Eigenschaften und Bedingungen eines Reinraumes sind und welche Anforderungen an die dort Beschäftigten gestellt werden.
The present paper describes the development of a sensor material that changes its fluorescence in the presence of gaseous ammonia in a relevant concentration range. The implementation into a semi-automatic gas measurement device enables low-cost, precise, simple and fast monitoring of low con-centrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.
In the present paper the development of a semi-automated device for long-term monitoring of gaseous ammonia is described. A sensor material was produced that changes its optical properties in the pres-ence of low concentrations of ammonia in air. The implementation into an electronic device enables precise, simple, economic and fast monitoring of low concentrations of harmful gases, like ammonia, and hence can help to improve the climate monitoring in livestock housing, barns or stables.
Playing with Droplets
(2018)
Microfluidic devices are powerful analytical tools with appealing features such as miniaturized size, low reagent and sample consumption, rapid response and short measurement times. As society wants to be ever better, earlier and more comprehensively informed about critical factors in life, work, and the environment, the demand for powerful measurement devices for use outside of the laboratory constantly increases.
Per- and polyfluoroalkyl substances (PFAS) represent a class of synthetic organofluorine chemicals extensively utilized in the manufacturing of various materials such as firefighting foams, adhesives, and stain- and oil-resistant coatings. In recent years, PFAS have been considered as emerging environmental contaminants, with particular focus on perfluoroalkyl carboxylic acids (PFCAs), the most prevalent type among PFAS. PFCAs are characterized by a fully fluorinated carbon backbone and a charged carboxylic acid headgroup. Notably, they have been designated as Substances of Very High Concern and added to the REACH Candidate List due to their persistence in the environment, non-biodegradability and toxicological effects.
Conventional techniques for the analysis of PFCA, such as GC-MS, HRMS and HPLC-based methods, are laborious, not portable, costly and require skilled personnel. In contrast, fluorescence assays can be designed as easy-to-operate, portable and cost-effective methods with high sensitivity and fast response, especially when analyte binding leads to a specific increase of a probe’s emission. Integration of such probes with a carrier platform and a miniaturized optofluidic device affords a promising alternative for PFCA monitoring.
Here, a novel guanidine BODIPY fluorescent indicator monomer has been synthesized, characterized, and incorporated into a molecularly imprinted polymer (MIP) for the specific detection of perfluorooctanoic acid (PFOA). The MIP layer was formed on tris(bipyridine)ruthenium(II) chloride doped silica core particles for optical internal reference and calibration-free assays. Such system allows selective and reliable detection of PFCA from surface water samples, with minimum interference by competitors, matrix effects and other factors. Integration of the assay into an opto-microfluidic setup resulted in a miniaturized and easy-to-operate detection system allowing for micromolar detection of PFOA in less than 15 minutes from surface water sample.
Pollution through emission of toxic gases is of utmost environmental concern, raising the interest in developing reliable gas sensors. Exemplarily, ammonia and its conversion products can provoke considerable damage on human health and ecosystems. Hence, there is a need for reliable and reversible sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for field measurements. Although various types of sensors such as potentiometric, amperometric, and biological sensors are available for detecting trace amounts of gases, fluorescent sensors have gained importance due to several advantages such as high sensitivity, possible miniaturization, as well as potential multiplexing. Herein, we present the development of a sensor material for gaseous ammonia in the lower ppm or even ppb range using optical fluorescence as transduction mechanism due to its intrinsically high sensitivity and high spatial resolution.[1] Therefore, a fluorescent dye, which shows reversible fluorescence enhancement in the presence of the analyte was incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. To calibrate the designed optical sensor system a gas standard generator was used, producing standard gas mixtures, which comply with the metrological traceability for ammonia gas standards in the desired environmentally relevant measurement range.[2] Beside the development of a highly sensitive, selective, and reversible sensor, the integration of such systems into mobile sensor devices is addressed. Therefore, a prototype of a miniaturized hand-held instrument was developed enabling a straightforward and long-term read-out of the measurement signal.
Because ammonia and its reaction products can cause considerable damage to human health and ecosystems, there is a need for reliably operating and reversibly interacting sensor materials to monitor traces of gaseous ammonia in ambient air, which at best can be used on-site for in-the-field measurements. Herein, the development of a sensor material for gaseous ammonia in the lower ppm to ppb range using optical fluorescence as transduction mechanism is presented. A fluorescent dye, which shows reversible fluorescence enhancement in the presence of ammonia is incorporated into a polymer matrix, the latter to ensure the accumulation of ammonia. The sensor material is integrated into a prototype of a miniaturized sensor device, facilitating long-term operation. To calibrate the optical sensor system a gas standard generator, producing standard gas mixtures, is used, leading to a sensitivity down to lower ppm concentrations of ammonia.
Mit Tröpfchen Spielen
(2018)
Mikrofluidische Systeme sind leistungsstarke analytische Tools mit attraktiven Eigenschaften wie miniaturisierter Größe, geringem Reagenzien und Probenverbrauch, schneller Ansprech- und kurzer Messzeit. Der Bedarf solcher leistungsstarken, miniaturisierten und direkt vor Ort anwendbaren Sensorsysteme steigt kontinuierlich, hauptsächlich durch das Bedürfnis der Gesellschaft, schneller, besser und umfassender über kritische Faktoren im Lebens- und Arbeitsumfeld sowie der Umwelt informiert zu sein.
There is significant contamination of our water resources and an accelerating accumulation of hazardous species in the aquatic biosphere. Whether for instance mercury as a contaminant constantly released from a multitude of industrial processes or chemical warfare agents (CWAs) such as Tabun (GA), Sarin (GB) or Soman (GD) as highly toxic remnants of World War II, released from dumped containers upon their progressive corrosion, are concerned such hazards can cause serious problems to human health even at low concentration and monitoring them becomes increasingly essential. Conclusively, it is necessary to develop sensors for such hazards that combine high sensitivity, good selectivity, fast responses and can dispense with complex instrumentation.
Here, we present SBA-15-type mesoporous silica materials containing boron–dipyrromethene (BODIPY) probes in their pore systems that allow for the sensitive and selective detection of the two target analytes CWAs and Hg2+ in natural waters via a change in the optical properties. In case of Hg2+, the BODIPY dye is directly adsorbed on the (inner and outer) surface of the highly porous material and coordinates the metal ion, leading to an enhancement of fluorescence with a limit of detection (LOD) of 15 ppt. Using the same silica material but incorporating a covalently attached BODIPY dye, the CWAs GA, GD and GB can be detected via fluorescence quenching induced by an intraannular cyclization. The obtained LOD in natural waters is in the pM range and hence below the Maximum Permissible Concentrations for CWAs in drinking water. Aspects of system design as well as application in water and food analysis (fish extracts) will be presented.
There is significant contamination of our water resources and an accelerating accumulation of hazardous species in the aquatic biosphere. Whether for instance mercury as a contaminant constantly released from a multitude of industrial processes or chemical warfare agents (CWAs) such as Tabun (GA), Sarin (GB) or Soman (GD) as highly toxic remnants of World War II, released from dumped containers upon their progressive corrosion, are concerned such hazards can cause serious problems to human health even at low concentration and monitoring them becomes increasingly essential. Conclusively, it is necessary to develop sensors for such hazards that combine high sensitivity, good selectivity, fast responses and can dispense with complex instrumentation.
Here, we present SBA-15-type mesoporous silica materials containing boron–dipyrromethene (BODIPY) probes in their pore systems that allow for the sensitive and selective detection of the two target analytes CWAs and Hg2+ in natural waters via a change in the optical properties. In case of Hg2+, the BODIPY dye is directly adsorbed on the (inner and outer) surface of the highly porous material and coordinates the metal ion, leading to an enhancement of fluorescence with a limit of detection (LOD) of 15 ppt. Using the same silica material but incorporating a covalently attached BODIPY dye, the CWAs GA, GD and GB can be detected via fluorescence quenching induced by an intraannular cyclization. The obtained LOD in natural waters is in the pM range and hence below the Maximum Permissible Concentrations for CWAs in drinking water. Aspects of system design as well as application in water and food analysis (fish extracts) will be presented.