Filtern
Dokumenttyp
- Zeitschriftenartikel (19)
Schlagworte
- LC-MS/MS (4)
- Quantification (3)
- Antikörper (2)
- Competitive assay (2)
- ELISA (2)
- Edible oil (2)
- Fluorescence polarization immunoassay (2)
- Isomerisation (2)
- Mycotoxin (2)
- Occurrence (2)
- SIDA (2)
- ZEA (2)
- Zearalenone (2)
- 13C labeling (1)
- 3ß-hydroxy-5ß-cholanic acid (1)
- Abwasser (1)
- Antibody production for hydrophobic molecules (1)
- Antioxidative activity of oligomeric model compounds (1)
- Arzneistoffe (1)
- Assay (1)
- Assay format (1)
- Assay optimization (1)
- Beta-dicarbonyl pathway of the Maillard reaction (1)
- Bile acids (1)
- Caffeine (1)
- Casein (1)
- Cis-ZEN (1)
- Crystal structure (1)
- Cyclization (1)
- DEHT (1)
- DINCH (1)
- Decaffeinated coffee (1)
- Depletion kinetics (1)
- Diclofenac (1)
- Diclophenac (1)
- Direct (1)
- Dynamic covalent hydrazine chemistry (DCHC) (1)
- E-screen assay (1)
- Emerging Pollutants (1)
- Enzyme immunoassay (1)
- Enzyme substrate (1)
- Ersatzstoffe (1)
- Estrogenicity (1)
- Fecal marker (1)
- Festphasenextraktion (1)
- Food (1)
- HPLC-MS (1)
- HPLC-MS/MS (1)
- HPLC–MS (1)
- HRMS (1)
- Hapten design (1)
- Hapten synthesis (1)
- Homogeneous immunoassay (1)
- Immunization monitoring (1)
- Immunoassay (1)
- Indirect (1)
- Isomerization (1)
- Kläranlage (1)
- MALDI-TOF-MS analysis (1)
- MCF-7 (1)
- Maize germ oil (1)
- Mix-and-read assay (1)
- Model compounds for melanoidins (1)
- Monoklonal (1)
- Norfuraneol (1)
- On-site measurement (1)
- Pathway (1)
- Peptide (1)
- Pesticide parathion-methyl (1)
- Pharmaceuticals (1)
- Pharmazeutika (1)
- Phase I metabolism (1)
- Phthalate (1)
- Phthalate substitutes (1)
- Polyclonal antibodies (1)
- Polycondensation (1)
- Probenvorbereitung (1)
- Pyrroles from pentoses and hexoses (1)
- Quality assurance criteria (1)
- Sample treatment (1)
- Samples (1)
- Schadstoffe (1)
- Selektivität (1)
- Sewage treatment plant (1)
- Solid-phase extraction (1)
- Solid-phase synthesis (1)
- Surface water (1)
- Temperature effects (1)
- Waste-water (1)
- Wastewater (1)
- Wastewater treatment plant (1)
- Weichmacher (1)
- Zyklisierung (1)
- caffeine (1)
Organisationseinheit der BAM
The reaction pathways of amino acids and reducing sugars are now fully understood. The focus in the last few years, however, has turned to the reaction of peptides and proteins with reducing sugars. We have investigated the reaction of γ-aminobutanoic acid, the heptapeptide Nα-Acetyl-Lys-Lys-β-Ala-Lys-β-Ala-Lys-Gly, and the model protein β-casein in Maillard reactions with 1-13C arabinose. Characterization of 13C-labeled acetic acid and norfuraneol by gas chromatographymass spectrometry and nuclear magnetic resonance revealed new formation pathways. The results demonstrate significant differences in the labeling pattern of the products depending on the amine used, indicating different formation pathways of acetic acid and norfuraneol.
Temperature is one factor that influences the performance of immunoassays. Most commonly all incubation steps of the immunoassay are performed at ambient temperature. To systematically study the influence of temperature deviations on assay parameters like signal variation coefficients, limit of detection and measurement range, direct competitive enzyme immunoassays for the determination of two anthropogenic markers, caffeine and carbamazepine, were run at different temperatures above and below room temperature during individual assay steps. The temperature during the competition step had the greatest impact on the assay sensitivity yielding changes in test midpoints by a factor of 10 to 15. For carbamazepine, the test midpoints varied from 36 ng L-1, 108 ng L-1 to 378 ng L-1 employing 4 °C, 21 °C, or 37 °C as incubation temperature, respectively. The edge effect can be minimized resulting in a good plate homogeneity with small variation coefficients, when the assay is performed at ambient temperature.
Enzyme immunoassays with optical detection are amongst the most widely used bioanalytical tools. We defined seven parameters for the quality assessment of immunoassays that were addressed in a systematic study of direct and indirect immunoassays, using the enzymes horseradish peroxidase (HRP) and alkaline phosphatase (AP), the chromogenic substrates 3,3',5,5'-tetramethylbenzidine (TMB) and para-nitrophenyl phosphate, and the fluorescent substrates 3-(4-hydroxyphenyl)propionic acid and 4-methylumbelliferyl phosphate. The same monoclonal antibody against caffeine was used throughout the study. The four quality parameters regarding the standard curve were the test midpoint (sensitivity), the measurement range, the relative dynamic range of the signal, and the goodness of fit of the adjusted four-parameter logistic function. All HRP immunoassays showed a higher sensitivity compared to the AP assays. On the basis of all four criteria, it was established that the direct assay format is superior to the indirect format, the immunoassay using HRP TMB fulfilling all requirements best. In a second step, caffeine concentrations in 24 beverage and cosmetics samples were determined and three more quality parameters were assessed with this application. The direct HRP TMB assay showed one of the best intra- and inter-plate precisions and the best accuracy, defined by the correlation of results with those from the chosen reference method liquid chromatography tandem mass spectrometry (LC-MS/MS). Considering all criteria, HRP TMB seems to be the enzyme substrate system of choice preferably used in the direct assay format.
Carbamazepine (CBZ) is one of the most frequently detected pharmaceuticals in water samples. For the determination of this anthropogenic marker, various immunoassay formats were tested and evaluated in order to identify the most suitable one. For these direct competitive assays, the analyte was labelled with the enzyme horseradish peroxidase (HRP) or alkaline phosphatase (AP), and seven substrates with specific detection properties were used. The quality criteria for the standard curves were fulfilled by all HRP assays and the chemiluminescence AP format. Furthermore, intra- and inter-plate coefficients of variation as a measure of the achievable precision were determined for the samples. The application of the AP assays to surface water was unfeasible due to CBZ concentrations below the quantifiable concentration range. Surface as well as waste water samples could be analyzed with the HRP assays. Here, the HRP assay employing the chromogenic substrate 3,3',5,5'-tetramethylbenzidine yielded the best results.
Pure U-[13C18]-labelled cis-zearalenone (cis-ZEA) has been prepared and characterised as internal standard (ISTD) for a reliable quantification of cis-ZEA in contaminated food and feed products. The cis-isomer of the naturally trans-configurated Fusarium mycotoxin zearalenone is often neglected. However, isomerisation easily occurs by exposure of ZEA to (UV-)light. Thus, the applicability of the new cis-ZEA ISTD was demonstrated in a long-term isomerisation study comparing naturally trans-ZEA-contaminated edible oil with spiked edible oil. To estimate the benefits of the newly prepared cis-ZEA ISTD, various approaches to quantify cis-ZEA by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) were compared. As a result, a significant bias was revealed if no appropriate cis-ZEA standards are used. Furthermore, the new ISTD was applied to the analysis of 15 edible oils by stable isotope dilution analysis in combination with HPLC-electrospray ionisation-MS/MS. One of the maize germ oils showed the presence of cis-ZEA above LOD (>0.3 µg/kg), whereas two out of 15 maize germ oils were found to be contaminated with trans-ZEA (range 17.0-31.0 µg/kg).
The present study investigates the in vitro phase I metabolism of cis-zearalenone (cis-ZEN) in rat liver microsomes and human liver microsomes. cis-ZEN is an often ignored isomer of the trans-configured Fusarium mycotoxin zearalenone (trans-ZEN). Upon the influence of (UV-) light, trans-ZEN isomerizes to cis-ZEN. Therefore, cis-ZEN is also present in food and feed. The aim of our study was to evaluate the in vitro phase I metabolism of cis-ZEN in comparison to that of trans-ZEN. As a result, an extensive metabolization of cis-ZEN is observed for rat and human liver microsomes as analyzed by HPLC-MS/MS and high-resolution MS. Kinetic investigations based on the substrate depletion approach showed no significant difference in rate constants and half-lives for cis- and trans-ZEN in rat microsomes. In contrast, cis-ZEN was depleted about 1.4-fold faster than trans-ZEN in human microsomes. The metabolite pattern of cis-ZEN revealed a total of 10 phase I metabolites. Its reduction products, α- and β-cis-zearalenol (α- and β-cis-ZEL), were found as metabolites in both species, with α-cis-ZEL being a major metabolite in rat liver microsomes. Both compounds were identified by co-chromatography with synthesized authentic standards. A further major metabolite in rat microsomes was monohydroxylated cis-ZEN. In human microsomes, monohydroxylated cis-ZEN is the single dominant peak of the metabolite profile. Our study discloses three metabolic pathways for cis-ZEN: reduction of the keto-group, monohydroxylation, and a combination of both. Because these routes have been reported for trans-ZEN, we conclude that the phase I metabolism of cis-ZEN is essentially similar to that of its trans isomer. As trans-ZEN is prone to metabolic activation, leading to the formation of more estrogenic metabolites, the novel metabolites of cis-ZEN reported in this study, in particular α-cis-ZEL, might also show higher estrogenicity.
Homogeneous fluorescence polarization immunoassays (FPIAs) were developed and compared for the determination of caffeine in beverages and cosmetics. FPIAs were performed in cuvettes in a spectrometer for kinetic FP measurements as well as in microtiter plates (MTPs) on a multimode reader. Both FPIAs showed measurement ranges in the µg/L range and were performed within 2 and 20 min, respectively. For the application on real samples, high coefficients of variations (CVs) were observed for the performance in MTPs; the CVs for FPIAs in cuvettes were below 4%. The correlations between this method and reference methods were satisfying. The sensitivity was sufficient for all tested samples including decaffeinated coffee without preconcentration steps. The FPIA in cuvettes allows a fast, precise, and automated quantitative analysis of caffeine in consumer products, whereas FPIAs in MTPs are suitable for semiquantitative high-throughput screenings. Moreover, specific quality criteria for heterogeneous assays were applied to homogeneous immunoassays.
Bile acids are relevant markers for clinical research. This study reports the production of antibodies for isolithocholic acid, the isomer of the extensively studied lithocholic acid. The IgG titer and affinity maturation were monitored during the immunizations of three mice and two rabbits. In both animal models, polyclonal antibodies with a high selectivity and affinity were produced. The development of a direct competitive ELISA with a test midpoint of 0.69 ± 0.05 µg/L and a measurement range from 0.09–15 µg/L is reported. Additionally, the crystal structure of isolithocholic acid is described for the first time.
Established maximum levels for the mycotoxin zearalenone (ZEN) in edible oil require monitoring by reliable analytical methods. Therefore, an automated SPE-HPLC online system based on dynamic covalent hydrazine chemistry has been developed. The SPE step comprises a reversible hydrazone formation by ZEN and a hydrazine moiety covalently attached to a solid phase. Seven hydrazine materials with different properties regarding the resin backbone, pore size, particle size, specific surface area, and loading have been evaluated. As a result, a hydrazine-functionalized silica gel was chosen. The final automated online method was validated and applied to the analysis of three maize germ oil samples including a provisionally certified reference material. Important performance criteria for the recovery (70–120 %) and precision (RSDr <25 %) as set by the Commission Regulation EC 401/2006 were fulfilled: The mean recovery was 78 % and RSDr did not exceed 8 %. The results of the SPE-HPLC online method were further compared to results obtained by liquid&–liquid extraction with stable isotope dilution analysis LC-MS/MS and found to be in good agreement. The developed SPE-HPLC online system with fluorescence detection allows a reliable, accurate, and sensitive quantification (limit of quantification, 30 µg/kg) of ZEN in edible oils while significantly reducing the workload. To our knowledge, this is the first report on an automated SPE-HPLC method based on a covalent SPE approach.