Schlagworte
- 4-Eye Principle (1)
- Automation Bias (1)
- Cellular polypropylene (1)
- Electromechanical effects (1)
- Electrostriction (1)
- Eye Tracking (1)
- Failure Modes and Effects Analysis (FMEA) (1)
- Ferroelectret (1)
- Ferroelectric devices (1)
- Human Factors (1)
Eingeladener Vortrag
- nein (1)
This paper gives an introduction to the field of human factors with the focus on their influence on the reliability of NDT in the nuclear energy production (in-service inspections) and final storage of highly radioactive nuclear waste. A set of methodological tools has been developed in the scope of three projects, namely: 1) a theoretical model describing potential human factors influencing manual ultrasonic inspection performance during inservice inspections in nuclear power plants; 2) a method for identifying potential human errors during acquisition and evaluation of data gathered with mechanized ultrasonic, radiographic and eddy-current systems, as well as visual testing with a remote camera (Failure Modes and Effects Analysis, FMEA); and 3) use of eye tracking methodology to optimize existing procedures and practices. The experimental results have shown that time pressure, mental workload and experience influence the quality of the inspection performance. Noticeable were influences from the organization of the working schedule, communication, procedures, supervision and demonstration task. Implementing human redundancy in critical tasks, such as defect identification, as well as using an automated aid (software) to help operators in decision making about the existence and size of defects, could lead to other kinds of problems, namely social loafing (excerpting less effort when working on tasks collectively as compared to working alone) and automation bias (uncritical reliance on the proper function of an automated system without recognizing its limitations and the possibilities of automation failure) that might affect the reliability of NDT in an undesired manner.
Electromechanical response of polypropylene ferroelectret transducers under application of high-voltage pulses was measured by laser Doppler vibrometry and compared with results of ultrasonic through-air transmission between two ferroelectret transducers. The electromechanical response was completely explained by piezoelectric and electrostrictive effects. The electrostrictive effect dominates at high voltages and provides significant enlargement of the transducer constant, up to factor of 2.5. The induced strain of 1.7% was achieved at – 2000 V. The nonlinear ultrasonic transmission was shown to be well described by the piezoelectric and electrostrictive response of transmitter, except in the range of high negative exciting voltages where some limitation of the transmitted signal was observed. This limitation seems not to be a fundamental one and does not abolish the advantages of high-voltage excitation of polypropylene ferroelectret transducers.