Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (55)
- Vortrag (51)
- Zeitschriftenartikel (18)
- Posterpräsentation (14)
- Beitrag zu einem Sammelband (7)
- Forschungsbericht (2)
- Dissertation (1)
- Sonstiges (1)
Sprache
- Deutsch (76)
- Englisch (72)
- Mehrsprachig (1)
Schlagworte
- Ferroelectret (26)
- Luftultraschall (21)
- Air-coupled (14)
- Transducer (14)
- Cellular polypropylene (13)
- Ferroelektret (12)
- Luftgekoppelte Ultraschallprüfung (11)
- Air-coupled ultrasound (10)
- Thermoakustik (10)
- Ultraschallwandler (9)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (56)
- 8.4 Akustische und elektromagnetische Verfahren (51)
- 6 Materialchemie (6)
- 6.1 Oberflächen- und Dünnschichtanalyse (6)
- 5 Werkstofftechnik (5)
- 5.3 Polymere Verbundwerkstoffe (5)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (5)
- 8.0 Abteilungsleitung und andere (3)
- 8.5 Röntgenbildgebung (1)
- 9 Komponentensicherheit (1)
Eingeladener Vortrag
- nein (51)
Rising importance of composite lightweight structures in aircraft and automobile industries increases the demand on reliable non-destructive testing methods for these structures. Air-coupled ultrasonic testing emerged to suit these requirements as it does not require any liquid coupling medium. In conventional air-coupled ultrasonic transducers, matching layers are used in order to decrease the impedance mismatch between transducer and air. Matching layers can be omitted by using ferroelectrets, which are charged cellular polymers having ferroelectric and piezoelectric properties. Especially a low Young’s modulus, low density and low sound velocity of cellular polypropylene (cPP) are properties being required for well-matched air-coupled ultrasonic transducers.
In our contribution we show recent enhancements of cPP transducers resulting in focused sound fields and thus improved lateral sensitivity. The influence of different transmitter apertures was evaluated using measurements of the emitted sound field. Further we show a transmission of a test specimen of carbon-fiber-reinforced plastic (CFRP) containing artificial damages. Results of focused transducers were compared to planar ferroelectret transducers, as well as to conventional air-coupled transducers.
Non-destructive testing (NDT) helps to find material defects without having an influence on the material itself. It is applied as a method of quality control, for online structural health monitoring, and for inspection of safety related components. Due to the ability of automation and a simple test setup ultrasonic testing is one major NDT technique next to several existing options. Whereas contact technique allows the use of higher frequencies of some MHz and phased array focusing, air-coupled ultrasonic testing (ACUT) shows different advantages. Most significant for ACUT is the absence of any coupling fluid and an economical test procedure respective time and costs. Both contact technique and ACUT have been improved and enhanced during the past years. One important enhancement is the development of airborne transducers based on ferroelectrets, like charged cellular polypropylene (cpp), which makes the application of any matching layers being mandatory in conventional piezoelectric transducers unnecessary. In this contribution we show ultrasonic inspection results of specimens made of carbon- and glass-fibre-reinforced plastic. These specimens include defects represented by drill holes and artificial delaminations of various size and depth. We compare inspection results achieved by using contact technique to those achieved by ACUT. For ACUT, conventional piezoelectric transducers and transducers based on cpp were used, both focused as well as non-focused types. Contact inspections were performed with a multi-channel matrix array probe. Once the inspection data is recorded it can be analysed in order to detect and evaluate defects in the specimen. We present different analysing strategies and compare these regarding detection rate and sizing of defects.
In the rapidly expanding composite industry, novel inspection methods have been developed in recent years. Particularly promising for air-coupled testing are cellular polypropylene transducers which offer better impedance matching to air than piezoelectric transducers. Furthermore, broadband transmitters (laser-induced ultrasound and thermoacoustic emitters) and receivers (optical microphones) have opened a completely new chapter for advanced contact-free ultra-sound inspection. X-ray dark-field radiography offers a different approach to detect porosity and microcracks, employing small angle X-ray scattering. These innovative ultrasonic and radiographic alternatives were evaluated in comparison with well-established inspection techniques. We applied thirteen different non-destructive methods to inspect the same specimen (a carbon fiber-reinforced polymer laminate with induced impact damage): air-coupled ultrasound testing (using piezoelectric transducers, broadband optical microphones, cellular polypropylene transducers, and a thermoa-
coustic emitter), laser-induced ultrasound testing, ultrasonic immersion testing, phased array ultrasonic testing, optically excited lock-in thermography, and X-ray radiography (projectional absorption and dark-field, tomosynthesis, and micro-computed tomography). The inspection methods were qualitatively characterized by comparing the scan results. The conclusions are advantageous for a decision on the optimal method for certain testing constraints.
Durch den Einsatz von faserverstärkten Kunststoffen und Multi-Material-Konstruktionen zur Gewichtsreduzierung erlangen Klebeverbindungen immer stärkere Bedeutung. Die Prüfung dieser Fügeverbindungen stellt neue Anforderungen an die zerstörungsfreie Prüfung. Hinzu kommt, dass die Zugänglichkeit häufig eingeschränkt und die Verwendung flüssiger Koppelmittel aufgrund konstruktiver oder fertigungstechnischer Gegebenheiten ausgeschlossen ist. Unter Berücksichtigung dieser Beschränkungen wurde ein Prüfverfahren entwickelt, das eine luftgekoppelte Anregung geführter Ultraschallwellen mit einer laserbasierten Detektion kombiniert. Nachdem das Prüfverfahren zunächst mit einer einfachen Signalauswertung im Zeitbereich getestet wurde, konnte in nachfolgenden Untersuchungen die örtliche Auflösung durch die Implementierung von Filteralgorithmen im Frequenz-Wellenzahl-Bereich und zusätzlich durch direktionale Filter erhöht werden. Das resultierende bildgebende Prüfverfahren wurde an realitätsnahen Klebeproben mit künstlichen Fehlern getestet. Die Zuverlässigkeit und Ortsauflösung des Verfahrens wurde im Vergleich mit herkömmlichen Prüfverfahren validiert. Mithilfe des Verfahrens können Poren, Einschlüsse und Bereiche mit ungenügender Verklebung detektiert werden.
Proposals for Performance Demonstration and Modular Reliability Assessment for Humanitarian Demining
(2003)
For safe and reliable demining it is necessary to determine the actual true performance of mine searching equipment in detecting mines. The subject to detect a hidden subject by penetrating physical interaction with the target is similar to that of non-destructive testing where it is looked for hidden cracks etc. in material via waves and rays. The non destructive testing profession is now about 100 years old and developed some procedures to check reliability of testing. Those principles like the performance demonstration where the successful detections are statistically evaluated against false calls rates and their implementation in an industrial standard (ASME section XI appendix VIII) are analysed. A first adoption to demining was accomplished in the prescription for blind trials in the CEN workshop agreement CEN BT 126
CWA07 for test and evaluation of metal detectors. A number of blind trials were accomplished within an ITEP project to learn about the necessary statistical layout of those trials to achieve true, reproducible and repeatable results to give guidance to selection and improvement of metal detectors. The special focus in these investigations was on the influence of the human factor due to the degree of experience of the operators and the infulence of uncooperative soil. The correlation of the results of the physical parameter measurement and the statistical results is analysed in a first attempt.
Because the demining process is always connected with a danger for human beings, it is necessary to make sure the proper functioning of mine searching equipment in detecting mines. Detecting a hidden target by penetrating physical interaction of rays or waves is similar to non-destructive testing. The non-destructive testing profession developed procedures to check the reliability of testing. These procedures, like the performance demonstration where the successful detections are statistically evaluated against false call rates and their implementation in an industrial standard (ASME section XI appendix VIII) are used as a template. A first adoption to demining was accomplished in the prescription for blind trials in the CEN workshop agreement CWA 14747: 2003 for test and evaluation of metal detectors. Within an ITEP project a number of blind trials were carried out to learn about the necessary statistical basis of those trials to achieve true, reproducible and repeatable results to give guidance for the selection and improvement of metal detectors. The special focus in this first investigation was on the influence of the human factor due to the different degree of experience of the operators and the influence of the soil.
Es werden die Fortschritte bei der Bewertung der Zuverlässigkeit von ZfP-Systemen in den vergangenen 10 Jahren vorgestellt. Der modulare Ansatz bzw. die systematische Auflistung aller wesentlichen Einflussfaktoren stehen am Anfang jeder Bewertung, die jeweils spezifisch für einen industriellen bzw. Feldeinsatz angelegt wird. Weiterhin legt die zu Grunde liegende Sicherheitsanforderung fest, ob ein exaktes quantitatives statistisches Ergebnis z. B. für die Fehlergröße, die mit hoher Sicherheit detektiert wird angestrebt wird oder ob man sich mit einer qualitativen Abschätzung zufrieden geben kann. Moderne Werkzeuge wie das 'Design of Experiments' (Statistische Versuchsplanung), die Volumen-POD für ein Bauteil als ganzes oder auch die systematische psychologische Betrachtung des menschlichen Faktors unterstützen die Treffsicherheit der Untersuchung für den gewünschten Einsatzfall. Die Ergebnisse der ZfP-Prüfungen können immer nur so gut sein, wie der Mensch mit den Bedingungen zurechtkommt. Weiterhin kann die POD im Zusammenhang mit den Prozessparametern als helfendes Optimierungswerkzeug eingesetzt werden und nicht als endgültige Be(Ver)urteilung. Es werden Beispiele aus Bereichen der Energieerzeugung und Endlagerung präsentiert.
The total reliability of a mine searching system is driven by the triple of intrinsic
capability, which describes the physical-technical basis capability, the application and
environmental factors and the human factors. Some of them can be determined in
laboratory measurements but the human factor and a part of environment conditions
and their interaction with the device need to be treated statistically. That is why the
test & evaluation procedure described in CEN CWA 14747:2003, includes in addition
to parameter tests of metal detectors also the reliability or blind field tests under local
conditions with local personnel. A series of three big field trials had been
accomplished in the ITEP-project 2.1.1.2 Reliability Model for Test & Evaluation of
Metal Detectors to specify the optimum conditions for reliable trial results with
affordable effort. For each set of specific working conditions, characterized in terms
of a combination of one mine type in one soil with one detector handled by local
personnel, the searching system will show up a working performance in mine
detection rates as a function of mine depth and show up a certain overall false call
rate. During the ITEP-trials in Benkovac and Oberjettenberg the authors learnt to
determine this function separately for each mine type in each soil, which is especially
important for low metal mines in uncooperative soil which will be illustrated for the
mine PMA2 in different types of soil. The question of representativeness for field
conditions on the one hand and necessary statistical set up for the possibility to
distinguish between individual detector performances is still under discussion.
The detection of defects in aircraft components or parts of a power plant or mines in the ground is connected with the task to distinguish between signals caused be the item searched for and noisy signals from other sources. The reliability of the system is the better the better the system is in detecting the wanted signal and avoiding false alarms caused by noise. It is usual to measure the reliability of diagnostic systems in terms of ROC-curves (Re-ceiver Operating Characteristics) and POD-curves (Probability of Detec-tion). The ROC curves describe the POD versus Probability of False Alarm with growing system sensitivity along the curve. POD curves describe the Probability of Detection for a fixed sensitivity for a variation of item sizes or depths. Reliability of the whole system is always a composition of the physics
and technique, application influences and the human factors. For the scien-tific understanding and possibilities of improvement, decomposition accord-ing to a modular model is helpful. The authors present their experiences with the reliability evaluation of metal detectors for humanitarian demining and an NDT system of mechanized ultrasonic phased array testing of copper welds. The special concern in demining is the influence of soil types, detec-tors and the experiences of human beings.