The current paper focuses on the determination of reliable numerical models of earth block masonry wallettes under different loading conditions. Uniaxial compression and diagonal compression tests were performed. Experimental behaviour was modelled with a non-linear model able to describe the cracking behaviour. The simplified approach based on macro-modelling shows a satisfactory accuracy and low computational costs. The results reproducing the uniaxial compression are in good correspondence with the post-elastic behaviour observed in the experimental campaign. The micro-modelling approach adopted to reproduce the shear behaviour, even with high computational cost, represents a suitable tool to predict the masonry collapse mechanism.
In this paper results of the experimental testing performed on brick masonry and earth block masonry are presented. The paper outlines the development of the testing procedures for two different types of anchors. For this purpose, two experimental campaigns of pull-out tests on masonry corner connections strengthened by metallic rod grouted were carried out. Experimental results proved that the implemented testing procedures are suitable to determine the most recurring failure modes of the anchor pins. Moreover, a procedure is proposed to estimate the capacity of grouted anchor pins based on experimental studies.
In the beginning of the 1980s earth building has undergone a renaissance, which nowadays leads to an increasing use of load-bearing earth constructions and in particular, earth block masonry. At present, there are no common structural standards according to the semi-probabilistic design concept, which is the state-of-the-art in European standards.
A solid database is needed for the determination of the partial safety factor on the resistance side. Therefore, compressive strength tests were carried out with two types of earth blocks and two types of prefabricated earth mortar. The evaluation showed that the variation of the compressive strength was remarkably less than expected, which seems to indicate high quality standards of the components earth block and mortar with regard to industrial production.
On the basis of these results and together with the reliability method, a partial safety factor for earth block masonry subjected to compression was determined. The main aim of the research was the development of a first valid database for material parameters of earth block masonry with particular regard to statistical characteristics. The results showed that a common calculation method for earth block masonry based on partial safety factors following the valid masonry construction standard is feasible.
Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behaviour of the single structural elements as well as by their mutual connections. Up to now limited data is available on the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate.
In this paper results of the experimental testing performed on earth block masonry are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel as well as glass fiber reinforced polymer (GFRP) rods with a lime based hydraulic grout and their compatibility with earth block masonry. GFRP rods were investigated as an alternative bonded-in anchorage material to the commonly used steel. In comparison with steel, they have a reduced weight and a reduced coefficient of thermal expansion. Their lower modulus of elasticity seems to be more compatible with the modulus of elasticity of earthen materials, although they exhibit a brittle fracture with lack of plastic phase.
In August 2013, the German National Institute for Standardization DIN published three national standards for industrially-produced earth building materials without the use of chemical stabilizers:
DIN 18945 Earth blocks definitions, building materials, requirements, test procedures DIN 18946 Earth masonry mortars definitions, building materials, requirements, test procedures DIN 18947 Earth plaster mortars definitions, building materials, requirements, test procedures The development of these standards was initiated by the Dachverband Lehm e.V. (DVL), the German umbrella organisation for building with earth. These standards are in accordance with the requirements of the EU Regulation No. 305/2011 which came into force in Germany on 1 July 2013. These basic requirements introduce provisions relating not only to the safety of buildings and other construction works but also to health, durability, energy economy, protection of the environment and other important aspects in the public interest. The basic requirements are defined by essential characteristics expressed by levels or classes, or in a description. The relevant essential characteristics define the performance of the construction product.
The DIN 18945, 46 and 47 outline unified test procedures describing the relevant essential characteristics of the earth building products as well as systems for assessing and verifying the constancy of their performance. The relevant systems of verification are determined by a national Technical Assessment Body (TAB), which in Germany is the Deutsches Institut für Bautechnik DIBt.
In this paper an extensive research campaign aimed to define the mechanical performance of earth block masonry panels is presented. Uniaxial compression and diagonal compression tests were performed. The test results confirmed the brittle behaviour of earth block masonry under uniaxial compressive load and showed that the failure of earth block masonry under shear load occurs by sliding of the earth blocks along the mortar joints after initial cracking in mortar joints and earth blocks. For diagonal compression test results showed that building technique practice is one of the key factors affecting the structural performances. Experimental behaviour was modelled with a non-linear model capable of describing cracking behaviour. Both micro-modelling and macro-modelling implementing isotropic or orthotropic material laws were used to assess the reliability of different modelling strategies. The model calibration was carried out by sensibility analysis of the input parameters to understand the influence of unit strength on the shear behaviour of masonry.