Filtern
Dokumenttyp
Schlagworte
- Ultraschall (3)
- Beton (2)
- Concrete (2)
- Phased array (2)
- Bauwesen (1)
- Blind source separation (BSS) (1)
- Blinde Quellentrennung (1)
- Codierte Sendesignale (1)
- EFIT (1)
- Elastodynamische Finite Integrationstechnik (1)
This paper describes an innovation of a phased array using dry contact probes to test concrete components. Based on preceding work on pressure waves, a low-frequency ultrasonic phased array consisting of shear wave probes is used in the experiments. This configuration allows the variation and control of the sound field directivity during the measurement. The measurements are carried out on a concrete test block using a scanning laservibrometer and a scanner system in transmission mode. The laboratory measurements are compared to theoretical calculations to investigate the influence of the probes shape and dimension on the resulting sound field patterns. The comparison of the modelling and the measurements demonstrates the suitability of the point source synthesis as a tool for the optimization of probe array designs. Methods of coded are used to improve the signal to noise ratio.
In den letzten Jahren werden vermehrt trocken ankoppelbare Ultraschall-Punktkontaktprüfköpfe erfolgreich für Prüfaufgaben im Bauwesen angewendet. Oft werden mehrere Punktkontaktprüfköpfe in einem Gehäuse zu einer Strahlergruppe kombiniert, um die Schallbündelung zu verbessern oder um einzelne Prüfköpfe nacheinander als Sender und Empfänger zu betreiben und die Messsignale nach der Messung einer SAFT-Auswertung zuzuführen. Alternativ können die einzelnen Prüfköpfe einer solchen Gruppe laufzeitgesteuert angeregt und dadurch schon während der Messung das Prüfkopfschallfeld beeinflusst werden. Für diese Technik sind die Bezeichnungen laufzeitgesteuerte Ultraschall-Gruppenstrahler oder 'Phased Array' gebräuchlich. Mit den präsentierten Untersuchungen sollen die Anwendungsmöglichkeiten der Gruppenstrahlertechnik im Niederfrequenzbereich durch den Einsatz von Punktkontaktprüfköpfen verbessert werden. Dazu werden verschiedene Wellenarten eingesetzt und der Einfluss der Anordnung der Strahlerelemente im Array untersucht.
Ultraschallmessverfahren werden seit Langem erfolgreich für Prüfaufgaben, wie zum Beispiel die Ermittlung von Bauteilgeometrien, im Bauwesen eingesetzt. Um die Schallbündelung der Prüfköpfe zu verbessern, werden oft mehrere Prüfköpfe in einem Array angeordnet. Für die Entwicklung der Prüfkopfarrays ist es zweckmäßig, mithilfe von Modellierungen den Einfluss der Arraygröße, der Anordnung der Einzelprüfköpfe im Array und der Prüffrequenz auf das Schallfeld zu untersuchen. Dazu werden in der Praxis erfolgreich Modellierungen auf der Basis der Elastodynamischen Finiten Integrationstechnik (EFIT) und der Punktquellensynthese angewendet. Beim Aufbau der Arrays kommen zurzeit immer häufiger Transversal-Punktkontaktprüfköpfe zur Anwendung. Daher wird bei der Beschreibung der Schallfeldberechnung insbesondere auf die der Transversalwellenprüfköpfe eingegangen und mithilfe von Modellierungen und Experimenten gezeigt, wie sich die Prüfkopfpositionierung auf die Richtcharakteristik auswirkt.
This paper deals with the development and investi-gation of a volatile organic compound (VOC) system for differ-ent scenarios. The integrated multi-sensor unit can detect dif-ferent gases through the integrated 3-fold VOC sensor, where-by a continuous measurement takes place. The system-integrated flow control, with pump and flow sensor, allows the gas molecules to be transported directly to the VOC sensor. The entire measurement is permanently stored on an integrat-ed Secure Digital (SD) card. If the previously determined limit range is exceeded, an alarm is generated. Due to the combina-tion of different components, numerous applications are possi-ble. The system is the first step or a tool towards further devel-opments in the field of gas sensors and is primarily used for the validation of chemically based gas sensors, and it is still largely extended by application-specific influences.
Dieser Beitrag stellt die aktuellen Fortschritte der Ultraschallprüfung von Betonbauteilen basierend auf dem ICA-Verfahren vor. Das eingesetzte Verfahren wird bereits erfolgreich in anderen Bereichen der Ultraschallprüfung angewendet. Das große Potential dieser Methode liegt in der Möglichkeit, die sich überlagernden Reflexionen der Ultraschallsignale durch nur wenige Messungen in Echtzeit voneinander zu trennen und durch einfache Triangulation zu lokalisieren.
Es wurden Experimente hinsichtlich der Eignung und praktischer Relevanz des JADE-Algorithmus durchgeführt. Die Untersuchungen erfolgten sowohl an Polyamid als auch an Betontestkörpern. Die Leistungsfähigkeit des JADE-Algorithmus bezüglich der Quellsignaltrennung wird anhand von mehrkanaligen Ultraschallmessungen gezeigt. Die extrahierten Komponenten enthalten Signalanteile, die mit den entsprechenden Echosignalen in der Messung korrelieren.
Zukünftig wird das untersuchte Verfahren mit der Gruppenstrahlertechnik und einem geeigneten Sende-Empfangskonzept kombiniert, um so die Aussagesicherheit der zerstörungsfreien Untersuchungen zu erhöhen.
Es wurden Untersuchungen hinsichtlich der Eignung und der praktischen Relevanz von codierten Sendesignalen als Anregungsimpulse für die Ultraschallprüfung von Betonbauteilen durchgeführt. Anhand von synthetischen Daten werden die theoretischen Vorteile der codierten Impulssequenzen gezeigt. Im Anschluss werden Barker- und Golay-codierte Sendesignale an einer Betonstufenplatte mit einem Größtkorn von 16 mm getestet.
Es zeigt sich das große Potenzial dieses Verfahrens, insbesondere bei Verwendung von Golay-Sequenzen als Anregung für die Ultraschallprüfköpfe. Es ergibt sich ein deutlich verbessertes Signal-Stör-Verhältnis im Vergleich zu den herkömmlichen bipolaren Rechteckimpulsen.