Filtern
Erscheinungsjahr
- 2017 (5) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (2)
- Vortrag (2)
- Zeitschriftenartikel (1)
Sprache
- Englisch (5)
Schlagworte
- Digital radiography (2)
- Aperture focusing (1)
- Back scatter imaging (1)
- CT (1)
- Co-planar translational laminography (1)
- Computer simulation (1)
- DIR (1)
- Deconvolution (1)
- Digital X-ray laminography (1)
- Evaluation of crack fields (1)
Eingeladener Vortrag
- nein (2)
This work presents an investigation of the accuracy of a radiographic simulation model applied to subsea pipeline inspections. Experimental measurements of a sample in a water tank are used to develop a set of calibrated simulation parameters for the modelling software aRTist. Image quality parameters such as signal-tonoise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. With this method signal-to-noise ratio was successfully matched while differences were still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough, however wall thickness measurements in tangential images, which are not based on absolute intensity, were found to produce similar results in simulated and experimental cases. The differences in contrast and intensity are thought to be due to detector backscatter and additional scatter from out-of-setup objects within the exposure bay, due to a lack of source collimation. These would affect the experimental results but were not included in the simulated setup. This was investigated by including different proportions of peripheral water and other objects in the modelled setup and examining the effect on Image quality parameters. Results show that this additional scatter has a significant impact on the radiograph, particularly on image contrast, and is therefore the likely cause of differences between experimental and simulated images. This implies that it will be very difficult to completely match simulated to experimental results, as including all possible scattering objects in the model would be very complex. An improvement could be made by using real subsea data to estimate this additional scattering, which could then be used to calibrate the model. However there would still be significant uncertainty in the ability of the model to accurately produce realistic intensity and contrast.
Classical film radiography is a well-established NDT technique and it is most commonly used for testing weld seams and corroded pipes e.g. in oil and gas industry or in nuclear power plants. In the course of digitization, digital detector arrays (DDA) are finding their way into industrial applications and are replacing film radiography step by step. This study deals with the latest generation of DDAs, the photon counting and energy resolving detectors (PCD), and their characteristics compared to charge integrating detectors (CID). No matter which technology to use, radiography still lacks a general issue: A three-dimensional object is projected onto a two dimensional image. Of course, advanced computed tomography (CT) algorithms exist since many years, but if the object to investigate is too large to fit into the manipulation system or its shape is not appropriate, CT is not feasible or sensible to be applied. To overcome this limitation, numerous laminographic algorithms have been developed in the past. In this study, photon counting detectors are used in combination with co-planar translational laminography to gain reconstructed three-dimensional volumes. Both laminographic testing and PCDs require a serious knowledge of many parameters that can influence the image quality in the resulting datasets. These are e.g. the detector efficiency and calibration procedure, setting of energy thresholds, exposure data, number of projections, beam length correction and spatial resolution. The use of PCDs yields more variables to be considered compared to CIDs. The most important parameters in laminographic testing and in the use of PCDs are described in this study and limits are discussed.
- Impact tests of concrete blocks
- High energy facility for laminographic testing
- Laminographic arrangement
- Cross-Laminography
- Measurement range extension by detector tiling
- Reconstruction methods
- Fast “shift averaging” method “next to base plane”
- reconstruction --> Removal of reinforcement indications
- 3D-Data analysis
- Crack-Segmentation by „Template Matching“
A special slit collimator was developed earlier for fast acquisition of X-ray back scatter images. The design was based on a twisted slit design (ruled surfaces) in a Tungsten block to acquire backscatter images. The comparison with alternative techniques as flying spot and coded aperture pin hole technique could not prove the expected higher contrast sensitivity. In analogy to the coded aperture technique, a novel multi slit camera was designed and tested. Several twisted slits were parallelly arranged in a metal block. The CAD design of different multi-slit cameras was evaluated and optimized by the computer simulation packages aRTist and McRay. The camera projects a set of equal images, one per slit, to the digital detector array, which are overlaying each other. Afterwards, the aperture is corrected based on a deconvolution algorithm to focus the overlaying projections into a single representation of the object. Furthermore, a correction of the geometrical distortions due to the slit geometry is performed. The expected increase of the contrast-to-noise ratio is proportional to the square root of the number of parallel slits in the camera. However, additional noise has to be considered originating from the deconvolution operation. The slit design, functional principle, and the expected limits of this technique are discussed.