Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- POD (7)
- Simulation (7)
- Radiography (6)
- Zuverlässigkeit (5)
- Zerstörungsfreie Prüfung (4)
- Endlagerung radioaktiver Abfälle (3)
- Modeling (3)
- Probability of detection (3)
- Radiographie (3)
- X-ray imaging (3)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (1)
The new standard ‘ISO 17636-2:2013: Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors’, defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.
Within the framework of the European project PICASSO, the radiographic simulator aRTist (analytical Radiographic Testing inspection simulation tool) developed by BAM has been extended for reliability assessment of film and digital radiography. NDT of safety relevant components of aerospace industry requires the proof of probability of detection (POD) of the inspection. Modeling tools can reduce the expense of such extended, time consuming NDT trials, if the result of simulation fits to the experiment. Our analytic simulation tool consists of three modules for the description of the radiation source, the interaction of radiation with test pieces and flaws, and the detection process with special focus on film and digital industrial radiography. It features high processing speed with near–interactive frame rates and a high level of realism. A concept has been developed as well as a software extension for reliability investigations, completed by a user interface for planning automatic simulations with varying parameters and defects. Furthermore, an automatic image analysis procedure is included to evaluate the defect visibility. The radiographic modeling from 3D CAD of aero engine components and quality test samples are compared as a precondition for real trials. This enables the evaluation and optimization of film replacement for application of modern digital equipment for economical NDT and defined POD.
X-ray computed tomography (CT) is a volumetric (3D) Imaging diagnostic method, well established in the medical field, and in industrial NDE as well. Developments in industrial CT aim to extent the applicability to complex structures, which do not allow the access of all directions. This are e.g. limited view, data and angle CT applications. New reconstruction algorithms are required on one
side, and the accuracy has to be improved on the other side. Numerical Simulation can support such developments by providing well defined data sets for the testing of reconstruction algorithms. This approach of virtual CT is realized within the radiographic simulator aRTist, developed by BAM. The poster shows the possibilities of this tool to consider complex scan paths. Simulated data sets have been reconstructed by an versatile backprojection algorithm.
X-ray scatter imaging is a well-established NDT technique to inspect complex objects using only a single-sided access. We present a specially designed multi-slit scatter camera consisting of several twisted slits which are parallelly arranged in a metal block. The camera projects one image per slit to the digital detector array, where the images are overlaying each other. The aperture is corrected based on a de-convolution algorithm to focus the overlaying projections into a single representation of the object. To achieve high scatter intensities from an object, it is necessary to optimize the parameters of the scatter system by simulation.
Within the framework of the European project PICASSO, the radiographic simulator aRTist (analytical
Radiographic Testing inspection simulation tool) developed by BAM has been extended for reliability
assessment of film and digital radiography. A simulation supported probability of detection (POD) methodology
has been developed and the validity of the approach has been studied using an application from the aeronautics
industry. An experimental POD has been determined with the help of a specialized software tool, developed to
aid with the collection of large series of POD data. The resulting POD is compared to simulations of the same
setting using aRTist and the newly available module for simulation supported POD. A quantitative agreement
within a few percent is achieved between the experimental and the simulation supported POD.
The reliability investigations are dedicated to throw light on the performance of the NDE system with
respect to the required aim. This is especially of interest when digitized and processed signals are
involved where it becomes hard to assess whether the quality of the system has raised or not. Three
different ways to investigate reliability of NDE signals will be described. The first way of investigation,
the performance demonstration, is preferred e.g. in the US American nuclear power industry. This is an
integral consideration of the non destructive test as a system where the whole NDE system is packed in a
black box and only the input in terms of the real existing flaws in the component is considered and
compared to the output in terms of the indications of the human inspector or of the automated system.
The second the European tradition relies on a standardized description of physical/technical
parameters of the NDE system which are preconditions for successful system performance. An example
for such a standardized set of performance parameters is given in the recently released standard about Xray
film digitization CEN EN 14096. The third approach the modular conception is a marriage of
both: The signal chain is cut into main modules. Each module is assessed in a most appropriate
individual way e.g. via modeling calculations. The single results are joint together according to the
reliability of the subsystems. Separating criteria for the system were proposed through a reliability
formula developed during a series of European-American workshops on NDE reliability. Examples of
all three approaches will be given.