The reliability investigations are dedicated to throw light on the performance of the NDE system with
respect to the required aim. This is especially of interest when digitized and processed signals are
involved where it becomes hard to assess whether the quality of the system has raised or not. Three
different ways to investigate reliability of NDE signals will be described. The first way of investigation,
the performance demonstration, is preferred e.g. in the US American nuclear power industry. This is an
integral consideration of the non destructive test as a system where the whole NDE system is packed in a
black box and only the input in terms of the real existing flaws in the component is considered and
compared to the output in terms of the indications of the human inspector or of the automated system.
The second the European tradition relies on a standardized description of physical/technical
parameters of the NDE system which are preconditions for successful system performance. An example
for such a standardized set of performance parameters is given in the recently released standard about Xray
film digitization CEN EN 14096. The third approach the modular conception is a marriage of
both: The signal chain is cut into main modules. Each module is assessed in a most appropriate
individual way e.g. via modeling calculations. The single results are joint together according to the
reliability of the subsystems. Separating criteria for the system were proposed through a reliability
formula developed during a series of European-American workshops on NDE reliability. Examples of
all three approaches will be given.
The computer simulation of radiography is applicable for different purposes in NDT such as for the qualification of NDT systems, the optimization of system parameters, feasibility analysis, model-based data interpretation, education and training of NDT/NDE personnel, and others. Within the framework of the European project PICASSO simulators will be adapted to support reliability assessments of NDT tasks. The radiographic simulator aRTist developed by BAM is well suited for this task. It combines analytical modelling of the RT inspection process with the CAD-orientated object description applicable to various industrial sectors such as power generation, aerospace, railways and others. The analytic model includes the description of the radiation source, the interaction of Radiation
with the material of the part, and the detection process with special focus to DIR. To support reliability estimations the simulation tool is completed by a tool for probability of detection (POD) estimation. It consists of a user interface for planning automatic simulation runs with varying parameters, specifically defect variations.
Further, an automatic image analysis procedure is included to evaluate the defect visibility and calculate the POD therefrom.
X-ray computed tomography (CT) is a volumetric (3D) Imaging diagnostic method, well established in the medical field, and in industrial NDE as well. Developments in industrial CT aim to extent the applicability to complex structures, which do not allow the access of all directions. This are e.g. limited view, data and angle CT applications. New reconstruction algorithms are required on one
side, and the accuracy has to be improved on the other side. Numerical Simulation can support such developments by providing well defined data sets for the testing of reconstruction algorithms. This approach of virtual CT is realized within the radiographic simulator aRTist, developed by BAM. The poster shows the possibilities of this tool to consider complex scan paths. Simulated data sets have been reconstructed by an versatile backprojection algorithm.
Die radiografische Bildqualität in ihrer klassischen Definition hängt von Kontrast, Rauschen und Unschärfe ab. Diese Parameter werden normalerweise mit Bildgüteprüfkörpern (BPK) bestimmt. Die Streustrahlung reduziert im Allgemeinen immer die Bildqualität in der Radiografie. Verschiedene Einflussgrößen werden unter Berücksichtigung von Techniken, wie Film-Radiografie, Computer-Radiografie mit Speicherfolien und digitale Radiographie mit Matrixdetektoren, analysiert. In Lehrbüchern und Standards werden das Streuverhältnis k und verschiedene Kontraste definiert. Für digitale Medien werden zusätzliche Parameter wie das Signal-Rausch-Verhältnis SNR und das Kontrast-Rausch-Verhältnis CNR eingeführt. In diesem Zusammenhang wird der Einfluss der Streustrahlung aus dem Messobjekt und dem Detektor bestehend aus Kassette bzw. Gehäuse und sensitiver Detektorschicht auf die Bildqualität ermittelt. Die numerische Modellierung wird eingesetzt, um die Streustrahlung und die Primärstrahlung aus dem Objekt separat zu bestimmen. Die Streustrahlung aus dem Objekt und Detektor erzeugen eine Abbildung des Objektes, die dem Primärstrahlungsbild überlagert ist, wobei das Streubild eine höhere Unschärfe aufweist. Dieser Effekt hängt von der Fehlergröße, dem Abstand zwischen Detektor und Objekt und der Zwischenfilterung ab.