Filtern
Dokumenttyp
- Zeitschriftenartikel (1)
- Beitrag zu einem Tagungsband (1)
- Vortrag (1)
Sprache
- Englisch (3) (entfernen)
Schlagworte
- Cross laminography (1)
- Focal spot measurement (1)
- Image quality (1)
- Laminography (1)
- Modulation transfer function (1)
- Reconstruction algorithms (1)
- Rotor blade (1)
- Standadization (1)
- Wind turbine (1)
- X-Ray tube (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (3) (entfernen)
Eingeladener Vortrag
- nein (1)
Digital Coplanar Translational Laminography (CTL) is a radiographic imaging technique that permits the visualization of structural details and discontinuities in the object of interest after 3D reconstruction from multiple projections. This technique becomes quite competitive regarding to computed tomography in situations of arrangements in which no complete rotation of the X-ray source - detector system around the object of interest is accessible or in cases where the part to be inspected has a high geometric asymmetry. The literature does not show many studies about image quality for different laminographic reconstructions and scan geometries.
Different methodologies for measuring the Modulation Transfer Function (MTF) as a key image quality parameter for the aforementioned technique are applied. The MTF was measured using different approaches, presampled MTF or sampled MTF, both based on the Fourier Transform-Magnitude Spectrum or the square wave
MTF using line pattern gauges. A sample known as Siemens Star with a converging line pattern was used to measure the circular square wave MTF. This circular MTF provides information on the direction dependent contrast transfer related to the measurement conditions, the reconstruction algorithms and the translational scan direction. For this purpose, several MTF measurements were performed in multiple angular directions. Beyond it, reconstructions were performed using different algorithms (Filtered Shifted Average) and an iterative one (MART – Multiplicative Algebraic Reconstruction Technique). Image quality analysis were done for both reconstruction methods. MART showed an image quality improvement for challenging conditions for laminographic arrangements, such as for a low number of projections (down to 25 for this study, considered as limited view, limited
angle reconstruction). Additionally, a Gadolinium gauge with parallel line patterns within a range from 10 μm to 1000 μm was used to compare the square wave MTF with the sine MTFs, measured by the different techniques mentioned above. The results show that the MTF techniques presented are equivalent in this study. The results obtained for this Gadolinium plate showed a good agreement between MTF10% and SRb image measurements. The methodology presented here is used for the characterization of the frequency dependent spatial resolution of measurements obtained from different laminographic reconstruction techniques and scan geometries. Finally, from the acquisitions and reconstructions obtained with the Siemens Star, cross laminographic images were calculated in order to improve the direction dependent sensitivity. The results showed a better detectability for cross laminographic images in comparison to unidirectional coplanar translational laminographic images covering dead zones.
3D structural investigations are described by X-ray laminography studies of sandwich shell segments, made of a PVC foam core, covered by non-crimp fabric glass fibre composite lay-ups processed by vacuum assisted resin infusion of epoxy. The specific scope of this study is to image transversal flaws within the foam core (joints) and of single ply overlaps. Test flaws were purposely implemented in order to simulate typical failure under cyclic load. In a dedicated test rig for shell structures, the flaw evolution/propagation is monitored by thermography and optical 3D inspection of deformation. Due to the unfavourable preconditions for classical computed tomography as of large aspect ratio, the samples were investigated by coplanar translational laminography. Its limited range of observation angles of ± 45°, results in anisotropic artefacts about the normal to the sample surface, but the typical flaws are well visualized in the as-prepared state, in a state of early damage, and in the repaired state.
New concepts for the measurement of focal spot parameters of nano- and microfocus X-ray tubes
(2019)
Accurate measurement of focal spot sizes of X-ray tubes, betatrons and linear accelerators is still an open problem. Several standards are currently active, which provide different results depending on the focal spot shape. CEN published the standard series EN 12543 (five parts) in 1999, which describes the measurement of focal spot sizes of X-ray tubes for NDT applications. The measurement procedure and its tolerances deviate from the measurement standards for medical X-ray tubes, e.g. EN 60336:2006 / IEC 60336:2005. EN 12543 describes different measurement methods for X-ray tubes with focal spots in several size ranges, defined as macrofocus, minifocus and microfocus. CEN TC 138 WG 1 und ASTM E 07.01 are revising (CEN) or have just revised (ASTM) the standards for focal spot size measurements, basing them on pin hole or edge measurements only. Slit cameras are applied for medical tube evaluation only. Tomographic methods for focal spot size shape reconstruction were proposed and will be discussed, but have not yet been used for standardization. The currently available standards cover the range of spot sizes from 5 µm up to several millimetres. During the last years, more and more nanofocus tubes have been developed for high-resolution applications and microscopy. Manufacturers and users apply different methods for measurement of nanofocus spot sizes and image resolution, which differ by a factor of up to two. These well-known methods and new alternative methods for the measurement of nanofocus spots (size and shape) will be evaluated and improved in the EMPIR project “NanoXSpot” in order to develop a related measurement standard.