The most substantial innovations in radiographic imaging techniques of the last two decades aim at enhanced image contrast of weakly absorbing micro and nano structures by taking advantage of X-ray refraction effects occurring at outer and inner surfaces. The applications range from fibre reinforced plastics to biological tissues. These techniques comprise, among others, X-ray refraction topography, diffraction enhanced imaging, phase contrast imaging, Talbot-Lau grating interferometry, and refraction enhanced imaging. They all make use of selective beam deflections up to a few minutes of arc: the X-ray refraction effect. In contrast to diffraction, this type of interaction has a 100 % scattering cross section, as shown experimentally. Since X-ray refraction is very sensitive to the orientation of interfaces, it is additionally a tool to detect, e.g., fibre or pore orientation. If the detector resolution exceeds the size of (small) individual features, one detects the integral information (of inner surfaces) within the gauge volume. We describe the above-mentioned techniques, and show their experimental implementation in the lab and at a synchrotron source. We also show strategies for data processing and quantitative analysis.
Traceable determination of non-static XCT machine geometry: New developments and case studies
(2022)
It is fundamental to determine the machine geometry accurately for dimensional X-ray computed tomography (XCT) measurements. When performing high-accuracy scans, compensation of a non-static geometry, e.g. due to rotary axis errors or drift, might become necessary. Here we provide an overview of methods to determine and account for such deviations on a per projection basis. They include characterisation of stage error motions, in situ geometry measurements, numerical simulations, and reconstruction-based optimization relying on image quality metrics and will be discussed in terms of their metrological performance. Since a radiographic calibration is always required to provide an initial absolute geometry, this method will be presented as well. The improvements of the XCT geometry correction methods are presented by means of case studies. The methods can be applied individually or in combination and are intended to provide a toolbox for XCT geometry compensation.