To complement the information provided by deterministic seismic imaging at length scales above a certain resolution limit we present the first application of adjoint envelope tomography (AET) to experimental data. AET uses the full envelopes of seismic records including scattered coda waves to obtain information about the distribution of absorption and small-scale heterogeneity which provide complementary information about the investigated medium. Being below the resolution limit this small-scale structure cannot be resolved by conventional tomography but still affects wave propagation by attenuating ballistic waves and generating scattered waves. Using ultrasound data from embedded sensors in a meter-sized concrete specimen we image the distribution of absorption and heterogeneity expressed by the intrinsic quality factor Q−1 and the fluctuation strength ɛ that characterizes the strength of the heterogeneity. The forward problem is solved by modeling the 2-D multiple nonisotropic scattering in an acoustic medium with spatially variable heterogeneity and attenuation using the Monte-Carlo method. Gradients for the model updates are obtained by convolution with the back-propagated envelope misfit using the adjoint formalism in analogy to full waveform inversion.
We use a late coda time window to invert for absorption and an earlier time window to infer the distribution of heterogeneity. The results successfully locate an area of salt oncrete with increased scattering and concentric anomalies of intrinsic attenuation. The resolution test shows that the recovered anomalies constitute reasonable representations of internal structure of the specimen.
Ultrasonic monitoring, making use of the sensitivity of the coda of repeated transmission meas-urements to changes in stress, temperature, moisture, as well as localized or distributed damage, has gotten at-tention in structural health monitoring (SHM) research recently. Analysis methods such as coda wave inter-ferometry (CWI), including its nonlinear extension, have been shown to be able to measure ultrasonic wave velocity changes with a 1∙10-5 resolution, while indicators such as cross-correlation or cross-coherence have been used to distinguish between reversible and irreversible changes. Several small- and large-scale laboratory experiments have demonstrated that stress changes in structures can be captured or damage detected in a very early stage. The use of this technique for pre-warning before failure are currently under investigation, as well as detailed research on the physical causes and the connection between ultrasonic wave properties and materi-al/structural behavior. Recently, several of large-scale laboratory and real structures have been instrumented with embedded ultrasonic transducers to gather experience and evidence on how to use this technology in re-al-world applications. Preliminary results from installations on a new bridge, an existing bridge, a tunnel, a la-boratory earthquake test as well as a historic stadium in Germany, Poland, and the United States, respectively, are presented. Environmental influences (mainly temperature) and validation by load tests are discussed.
Die Überwachung von Bauteilen aus Stahl- oder Spannbeton mit Ultraschall hat in Labor- und Technikumsversuchen schon vielversprechende Ergebnisse gezeigt. Besonders gute Resultate wurden dabei mit eingebetteten Ultraschalltrans-ducern und bei Auswertung der Daten mit der hochsensiblen Codawelleninterferometrie erzielt. Erfasst werden können neben Temperatur- und Feuchteeffekten auch Belastungszustände und jegliche Art von Schädigung, die mit Mikro- oder Makrorissbildung einhergeht.
Seit 2019 untersucht die DFG-Forschergruppe 2825 „CoDA“ (Sprecher: Prof. Christoph Gehlen, TU München) ver-schiedenste Aspekte dieser innovativen Technologie mit dem Ziel, Einflussgrößen quantitativ zu erfassen, Umweltein-flüsse zu korrigieren und 3D-Auswerteverfahren zu verbessern. Final soll eine am Bauwerk einsatzfähige Methode ent-stehen, die klassische Monitoringverfahren ergänzt und erweitert sowie Input zu einem Update des statischen Systems liefert.
Aufgaben der BAM in der Forschergruppe ist neben Verbesserung und Adaptierung der Messsystem und Sensorik auch Langzeitversuche an einem Großobjekt und Testinstallationen an Realbauwerken. Hierzu liegen erste Ergebnisse vor, die zeigen, dass die Technologie auch außerhalb des Labors einsatzfähig ist.
Zerstörungsfreie Prüfverfahren liefern wichtige Informationen zur Beurteilung von Bauwerken. Mit ihnen können Materialeigenschaften bestimmt oder die innere Struktur von Bauteilen beschrieben werden. Für letzteres werden in der Regel Volumenverfahren angewandt. Einen besonderen Stellenwert haben in der Praxis die Radar- und die Ultraschall-Echoverfahren.
Ihre Anwendung erfordert lediglich eine einseitige Zugänglichkeit
zum Bauteil. Zudem lassen sich zahlreiche unterschiedliche Prüfaufgaben lösen. Zum Stand der Technik gehören beispielsweise die Ortung von Bewehrung und Spannkanälen, die Bestimmung der Dicke von Bauteilen oder die Fehlerlokalisierung.
In diesem Beitrag wird gezeigt, wie mithilfe von Ultraschall-Echomessungen gesammelte Messwerte in ein quantitatives Messergebnis überführt werden können, das wiederum in ingenieurtechnische Berechnungen einfließen kann. Einleitend werden die Prüfmethode und die Messtechnik erläutert. Anschließend wird das Vorgehen von der Auswertung der Messergebnisse bis zur Bestimmung der bautechnischen
Kenngröße – Bauteildicke – gezeigt. Abschließend wird die Methodik an einem Referenzprüfkörper aus Polyamid demonstriert und den Ergebnissen von Messungen an Beton gegenübergestellt.
This paper describes a new ultrasonic measuring device called “W-Box”. It was developed based on the requirements of the DFG Forschergruppe (research unit) CoDA for a portable device for monitoring of concrete specimens, models and actual structures using embedded ultrasonic transducers as well as temperature and humidity sensors. The W-Box can send ultrasonic pulses with a variable frequency of 50–100 kHz to one selectable transducer and records signals from up to 75 multiplexed channels with a sample rate of 1 MHz and a resolution of 14 bits. In addition, it measures temperature and humidity with high accuracy, adjustable amplification, restarts automatically after a power failure and can be fully controlled remotely. The measured data are automatically stored locally on-site data quality checks and transferred to remote servers. The comparison of the W-Box with a laboratory setup using commercial devices proves that it is equally reliable and precise, at much lower cost. The W-Box also shows that their measurement capacities, with the used embedded ultrasonic transducers, can reach above 6 m in concrete.
Ultrasonic coda wave interferometry can detect small changes in scattering materials like concrete. We embedded ultrasonic transducers in the Gänstorbrücke Ulm, a monitored road bridge in Germany, to test the methodology. Since fall 2020, we've been monitoring parts of the bridge and comparing the results to commercial monitoring systems. We calculate signal and volumetric velocity changes using coda waves, and long-term measurements show that the influence of temperature on strains and ultrasound velocity changes can be monitored. Velocity change maps indicate that different parts of the bridge react differently to environmental temperature changes, revealing local material property differences. A load experiment with trucks allows calibration to improve detectability of possibly damaging events. Our work focuses on measurement reliability, potential use of and distinction from temperature effects, combination with complementary sensing systems, and converting measured values to information for damage and life cycle assessment.
Ultrasonic Coda Wave interferometry has the potential to detect minute changes in scattering materials like concrete. By permanently installing ultrasonic transducers in concrete, DFG Research unit CoDA aims to develop methods for concrete damage assessment in Germany's aging infrastructure. To test the methods developed in simulations and laboratory experiments on a large scale, we have implemented several ultrasonic transducers at the Gänstorbrücke Ulm, one of Germany's most monitored road bridges. Since fall 2020 we are monitoring parts of the center of the Bridge, as well as an abutment, and compare the results to the commercial monitoring system. All data is recorded with a self-made data collection device, the so-called W-Box, and analyzed with different coda wave-based algorithms to detect signal and volumetric velocity changes. The long-term measurements show that the influence of temperature changes on strains and therefore ultrasound velocity changes calculated with coda waves can be monitored. The capabilities and limitations of the coda wave-based monitoring system are tested in a controlled experiment. Static loading using a truck with varying loads at several positions allows the calibration of the system to improve the detectability of possibly damaging loads and changes induced by this loading. A map of velocity change analyzing data from this load experiment shows that the influence of load on the material and strain distribution can be detected with array measurements.
The ‘Gänstorbrücke’ bridge between the cities of Ulm and Neu-Ulm is one of the best-monitored bridges all over Germany. In addition to an already active bride monitoring system, we have equipped the bridge with 30 ultrasonic transducers to explore the monitoring possibilities at an in-service large-scale reinforced concrete structure with continuous active ultrasonic measurements. The monitoring system is based on the detection of small changes in the entire signal, especially the multiply scattered parts of the recording, the so-called coda. Applying Coda Wave Interferometry (CWI), subtle changes in the signal can be detected and related to changing velocities in the area between source and receiver. A comparison of the results from coda wave interferometry with the strain measurements of the permanent monitoring system shows a correlation between strain measurements and CWI results. We discuss the challenges of changing environmental conditions, pose for interpretation of the results, and highlight the advantages of embedded versus externally attached ultrasonic transducers in permanent bridge monitoring, especially when coda wave interferometry is applied.
Due to the importance of reinforced concrete structures for modern society, damage assessment during the entire life-cycle of such structures has become a special interest in non-destructive testing. Using embedded ultrasound sensors in combination with other measurement methods, numerical modeling and self-made data collectors, tailored specifically for monitoring tasks, the German research group DFG FOR CoDA aims to investigate and develop novel methods for damage detection and rapid model updating in reinforced concrete structures. In the first stage of the project, besides the development of custom-built, low-cost data collectors, ultrasonic transducers are embedded in a large, reinforced concrete specimen on a BAM test site near Berlin. In this experiment, the influence of changing environmental conditions (mainly temperature) on the ultrasound signal is investigated using coda-wave interferometry. The results show a correlation between changes in temperature and ultrasonic velocity. Such changes must be taken into consideration in a long-term monitoring setup to distinguish between reversible and permanent changes. By correcting the data using a linear relation between concrete temperature and velocity change to remove the seasonal trends and by low-pass filtering the data to remove daily variations can remove most of the temperature influence on the ultrasound measurements.
Ultrasound measurements in concrete are a well-known technique in civil engineering and non-destructive testing.
For consistent monitoring of a concrete structure, the common techniques, using external sensors can often not provide the appropriate degree of repeatability, as the surface of structures changes, and comparable coupling conditions cannot be guaranteed when a measurement is repeated after some time. By embedding ultrasound transducers in concrete, we aim to develop a strategy for long-term monitoring of infrastructure, especially bridges, as a supplement and extension to other techniques. Applying the so-called coda wave interferometry to these measurements we can detect subtle changes in the medium far beyond the Resolution limit of traditional time of flight methods. A smart sensor layout enables cost-efficient sensing of the entire area of interest.
Embedding the transducers might remove uncertainties like coupling or positioning changes, while other challenges remain.
Temperature and moisture content influence the structure and the transducers. These drifts need to be recorded and removed and good coupling must be ensured while not being able to visually inspect the sensor. In a multidisciplinary research group funded by the German Research Foundation, we aim to solve these problems on the way towards an ultrasound monitoring system for reinforced concrete structures. In various experiments in the lab and field, we determine the influence of temperature variations on the measurements and the equipment. As the monitoring task is the detection of irreversible damages - not reversible changes - a smart system requires a smart way of discrimination between permanent damages and reversible changes. With the data collected in these experiments, we present an approach to an environmental correction to ultrasound data to avoid a
misinterpretation of these environmental changes as damage indicators.