One of the unresolved issues of the European Water Framework Directive is the unavailability of realistic water reference materials for the organic priority pollutants at low nanogram-per-liter concentrations. In the present study, three different types of ready-to-use water test materials were developed for polycyclic aromatic hydrocarbons (PAHs), polybrominated diphenyl ethers (PBDEs) and tributyltin (TBT) at nanogram-per-liter levels. The first type simulated the dissolved phase in the water and comprised of a solution of humic acids (HA) at 5 mg L-1 dissolved organic carbon (DOC) and a spike of the target compounds. The second type of water sample incorporated the particulate phase in water. To this end, model suspended particulate matter (SPM) with a realistic particle size was produced by jet milling soil and sediments containing known amounts of PAHs, PBDEs and TBT and added as slurry to mineral water. The most complex test materials mimicked 'whole water' consequently containing both phases, the model SPM and the HA solution with the target analytes strongly bound to the SPM. In this paper, the development of concepts, processing of the starting materials, characterisation of the HA and model SPMs as well as results for homogeneity and stability testing of the ready-to-use test materials are described in detail.
We have prepared and evaluated three whole water test materials containing eight polycyclic aromatic hydrocarbons (PAHs), six polybrominated diphenyl ethers (PBDEs) and tributyltin (TBT) with respect to homogeneity and short-term stability. The test materials were used as samples in two inter-laboratory comparisons. The materials were composed of natural mineral water and model suspended particulate matter (SPM) containing the target compounds at ng L-1 levels. The expanded uncertainty of the estimated mass concentrations in the final test materials was obtained by combining contributions from the homogeneity, the stability and the model SPM characterization.
The whole water materials were sufficiently homogeneous and stable at 4 °C for their intended use. In total, 12 out of 15 investigated target parameters could be assessed to be present with a relative combined expanded uncertainty below 25 %. The outcome of the two interlaboratory comparisons confirmed the good quality of the test materials and the level of uncertainties associated with the estimated mass concentrations. These findings are an important contribution towards the development of whole water matrix reference materials certified for PAH, PBDE and TBT in support of the Water Framework Directive of the European Union.
The European Water Framework Directive 2000/60/EC requires monitoring of organic priority pollutants in so-called whole water samples, i.e. in aqueous nonfiltered samples that contain natural colloidal and suspended particulate matter. Colloids and suspended particles in the liquid phase constitute a challenge for sample homogeneity and stability. Within the joint research project ENV08 ‘‘Traceable measurements for monitoring critical pollutants under the European Water Framework Directive 2000/60/EC’’, whole water test materials were developed by spiking defined amounts of aqueous slurries of ultrafinely milled contaminated soil or sediment and aqueous solutions of humic acid into a natural mineral water matrix. This paper presents the results of an European-wide interlaboratory comparison (ILC) using this type of test materials. Target analytes were tributyltin, polybrominated diphenyl ethers and polycyclic aromatic hydrocarbons in the ng/L concentration range. Results of the ILC indicate that the produced materials are sufficiently homogeneous and stable to serve as samples for, e.g. proficiency testing or method validation. To our knowledge, this is the first time that ready-to-use water materials with a defined amount of suspended particulate and colloidal matter have been applied as test samples in an interlaboratory exercise. These samples meet the requirements of the European Water Framework Directive. Previous proficiency testing schemes mainly employed filtered water samples fortified with a spike of the target analyte in a water-miscible organic solvent.
Certified water reference materials are currently not available for most of the hydrophobic organic pollutants listed in the EU Water Framework Directive. To find the most suitable container type for subsequent reference material productions, feasibility studies for the preparation of waters with polycyclic aromatic hydrocarbons (PAHs), polybrominated diphenyl ethers (PBDEs) and tributyltin (TBT) close to environmental quality standards in water have been performed. Due to the hydrophobic nature of these compounds and their tendency to adsorb onto container walls, an adequate selection of the most appropriate material for containment, storage and transport of water reference materials is crucial. Three different materials (aluminium, amber glass and fluorinated polyethylene, FPE) and three volumes (500/600 mL, 1000/1200 mL and 2000/3000 mL, depending on commercial availability) were tested at ng L-1 level of the target compounds. FPE shows by far the highest loss of analytes due to adsorption onto the container walls for all compounds studied. Aluminium and glass are equally suited for PAHs and PBDEs, but aluminium is unsuitable as container material for TBT due to acid cleaning requirements. The volume of the containers had no dramatic effect on the adsorption behaviour of target compounds for the different volumes tested.
The meeting was organised by the European Commission’s Joint Research Centre and held at the JRC-Geel site on 22–23 February 2018. It was a follow-up of a similar meeting held in 2009. The objective of the meeting was to exchange information about ongoing publicly funded reference material (RM) production, identify areas of interest for future specific RMs, including certified reference material (CRM) developments, investigate potential areas of collaboration, and to identify areas which may be of a lower importance in the future for a specific RM producer. The benefit of exchanging such information is to avoid duplication of efforts in RM production, make better use of public funds by potentially matching competencies, and to address problems that are common to publicly funded RM producers.
Production of three certified reference materials for the sulfur content in gasoline (petrol)
(2007)
Directive 2003/17/EC of the European Parliament and the European Council stipulates that petrol (gasoline) with a total sulfur content below 10 mg kg-1 must be available in all European Union member states by 2009. Three certified reference materials were produced in support of this directive in a joint effort of the members of the European Reference Materials Initiative (ERM). Two of the materials were made from commercial petrol, while the third one was prepared from a blend of commercial petrols. Relative between-ampule heterogeneity of the materials was quantified and found to be below 2.5%. Potential degradation during storage and dispatch was quantified, and shelf lives based on these values were set. The three materials were characterized by three institutes using different variants of isotope-dilution mass spectrometry. The results from the three institutes were combined, and the final uncertainties of the respective sulfur mass fractions were estimated including contributions from heterogeneity, stability, and characterization. The following mass fractions were derived: ERM-EF211, 48.8 ± 1.7 mg kg-1; ERM-EF212, 20.2 ± 1.1 mg kg-1; and ERM-EF213, 9.1 ± 0.8 mg kg-1.