Filtern
Dokumenttyp
Sprache
- Englisch (4)
Referierte Publikation
- ja (4) (entfernen)
Schlagworte
- Abdominal appendages (1)
- Adult insects (1)
- Bauplan (1)
- CT (1)
- Casting (1)
- Coordinate metrology (1)
- DIVA algorithm (1)
- Defects (1)
- Diesel particulate filters (1)
- Edge artefact (1)
Despite their enormous diversity, the bauplan of adult winged insects (pterygotes) is remarkably conservative since the Lower Devonian: a five-segmented head, a three-segmented thorax with three pairs of walking legs and an eleven-segmented abdomen without any non-sexual appendages 1 and 2. The only known exceptions are the abdominal appendages of adult male sepsid flies on the fourth segment; however, these are also used as copulatory organs and are supposedly maintained through sexual selection [3]. Here, we report a rod-like paired appendage from the third and fourth abdominal segments in adults of the Southeast-Asian Hemiptera taxon Bennini (Figure 1A,B; Supplemental information). These are fully musculated, innervated, and movable and bear highly organized sensory and secretory units. The appendages, termed LASSO (lateral abdominal sensory and secretory organs), are consistent in topology and structure in all species studied and not sexually dimorphic. The existence of these non-sexual abdominal appendages reveals the potential of the 300 million year old conserved bauplan of insects.
We present a modified aluminium casting which is especially suited as test piece for measuring casting defects and the geometry by means of cone-beam micro-focus X-ray systems, and which may become a reference standard for dimensional measurements and defect detection.
To obtain a test piece with inner geometries measured by tactile means, we divided a small aluminium cylinder head into four pieces in such a way that most inner surfaces can be reached with a tactile probe. Reference geometries (spheres and cylinders) were applied to define a coordinate system for aligning the measurements in the disassembled and re-assembled state. The four pieces were re-assembled after the tactile measurement.
The test piece also contains casting defects. In order to be able to use the assembled cylinder head as reference sample for defect detection, measurements with higher spatial resolution and better signal-to-noise ratio were performed on the single parts. For improving the reliability of the reference measurements, CT measurements of each part were carried out in three different orientations, and the individual defect detections were combined to obtain a reference data set with a high probability of defect detection and a low rate of erroneous detections.
A new method for comparing the defect detection in a CT measurement to a reference data set is demonstrated, which provides individual information on every detected flaw.
We discuss the results of measurements in the assembled state with respect to the reference data for flaw detection.