The successive fatigue failure process, i.e. crack initiation and growth up to electrical failure, has been investigated for a flip chip configuration. A cracked and uncracked solder bump was analysed using an unified viscoplastic constitutive model (Chaboche). The electrical failure of a bump seems to be reached in general not before a deep crack has grown into the bump. In order to update the actual loading situation two different cracked structures were calculated.