Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (23)
- Vortrag (23)
- Zeitschriftenartikel (19)
- Beitrag zu einem Sammelband (9)
- Buchkapitel (7)
- Posterpräsentation (3)
- Handbuch (2)
- Forschungsbericht (2)
- Sonstiges (1)
Sprache
- Englisch (45)
- Deutsch (43)
- Mehrsprachig (1)
Schlagworte
- Sensorik (7)
- Messtechnik (6)
- Monitoring (5)
- Structural health monitoring (5)
- Application (2)
- Ausgleichsrechnung (2)
- Characterisation (2)
- Digital image correlation (DIC) (2)
- Digitale Bildkorrelation (DIC) (2)
- Drop test (2)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (5)
- 8.0 Abteilungsleitung und andere (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 8.5 Röntgenbildgebung (2)
- 9 Komponentensicherheit (2)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
Eingeladener Vortrag
- nein (23)
Eine gleich bleibend effektive Nutzung von Anlagen, Rohstoffen und Energie in Verbindung mit der optimalen Prozessführung sind die wichtigsten Voraussetzungen für globale Wettbewerbsvorteile der Prozessindustrie.
Unternehmen aus den Bereichen Chemie, Pharmazie, Petrochemie, Gasverarbeitung, Lebensmittel-, Zellstoff-, Papier-, Glas-, Stahl- und Zementherstellung sowie ihren Zulieferern haben den Einsatz zuverlässiger Prozessautomation für eine gute Prozessführung erkannt. Überlegene Verfahren stützen sich zunehmend auf prozessanalytische Messtechnik zur Kontrolle und präventiven Sicherstellung der geforderten Produktqualität. Gleichzeitig ermöglicht sie eine ständige Verbesserung des Wissens über den Prozess und erhöhen die Prozess- und Anlagensicherheit.
Langzeit-Monitoring an den Spannbetonbrücken des neuen Hauptbahnhofs Berlin (Lehrter Bahnhof)
(2008)
Spannbetonbrücken des neuen Hauptbahnhofs in Berlin, die etwa 170 m lang sind und auf 12 Stützen ruhen, werden für viele Jahre mit einem Monitorsystem überwacht. Gemessen werden langzeitig auftretende Setzungen und Hebungen an den Auflagerpunkten. Für die Messungen wird ein hydrostatisches und ein laseroptisches System für die vertikalen Verformungen eingesetzt, daneben Neigungsmesser und Dehnungsaufnehmer (elektrische und faseroptische) sowie Temperatur-Sensoren. Für die Auswertung wird eine neuartige Symbiose von experimenteller und mechanisch-numerischer Analyse angewendet.
Meßtechnik und Sensorik
(2007)
The optical transmission stability was investigated for commercially available polymer optical fibers (POFs) which were exposed to a climate of 92°C and 95% relative humidity for about 3300 h. The optical transmission stability of POFs was correlated to their thermooxidative stability. POFs possessed identical core material, poly(methyl methacrylate), but they differed in the materials used for the claddings. The optical transmission was measured online using a prototype device called multiplexer. The chemiluminescence (CL) technique was applied to characterize the thermooxidative stability and degradation of POFs. CL analysis reveals the thermooxidative degradation of bare POFs (core and cladding), predominantly of the claddings, as a result of climatic exposure. Ultraviolet-visible transmittance measurements demonstrated more changes in the claddings as compared to the cores due to degradation. The CL and optical measurements data indicated that the optical transmission stability of POFs was dependent mainly on the thermooxidative stability of the claddings and their chemical compositions.
The thermo-oxidative stability of commercially available polymer optical fibers (POFs) and their components (cores and claddings) was investigated. All the bare POFs (core and cladding only) studied here were based on poly(methyl methacrylate) (PMMA) core. The fibers were exposed to 100 °C/low humidity for about 4200 h. Chemiluminescence (CL) technique was applied to investigate the thermo-oxidative stability and for measuring the transmission loss during exposure a prototype device called multiplexer was used. POFs exhibited variation in thermo-oxidative stability although they possessed identical core material PMMA. This was due to difference in the chemical compositions of claddings. Claddings were more susceptible to the thermo-oxidative degradation compared to cores. The thermo-oxidative degradation of both the cladding and the core was found in POFs as a result of climatic exposure. POFs showed an early drop-off followed by a slow decline of transmission. The early drop-off of transmission was attributed to physical changes like thermal expansion and the slow decline of transmission to chemical changes like oxidative degradation of POFs. A good linear relationship between optical transmission stability and thermo-oxidative stability of POFs was established from these studies.
Ergebnisunsicherheit im Prüfwesen- Eine Einführung in Systematik und praktische Vorgehensweisen
(2005)
Ergebnisunsicherheit im Prüfwesen - eine Einführung in Systematik und praktische Vorgehensweisen
(2005)
Embedded conventional fibre Bragg grating (FBG) sensors with acrylate coating have been chosen for monitoring novel textile-reinforced composite materials with a complicated wavy structure as a result of reinforcing textures. Problems of monitoring this type of material occur due to the harsh fabrication technology of the composite and its complicated structure. Embedded fibre sensors are exposed to the influence of transverse and point-wise deformations. To what extent will these effects influence the measurement signal of a sensor? Temperature cycles, tension and vibration tests were carried out to answer this question. Transverse and point-wise deformation and micromechanical indentation tests on non-embedded FBG sensors were carried out to clarify the reliability of recorded signals.