Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (23)
- Vortrag (23)
- Zeitschriftenartikel (19)
- Beitrag zu einem Sammelband (9)
- Buchkapitel (7)
- Posterpräsentation (3)
- Handbuch (2)
- Forschungsbericht (2)
- Sonstiges (1)
Sprache
- Englisch (45)
- Deutsch (43)
- Mehrsprachig (1)
Schlagworte
- Sensorik (7)
- Messtechnik (6)
- Monitoring (5)
- Structural health monitoring (5)
- Application (2)
- Ausgleichsrechnung (2)
- Characterisation (2)
- Digital image correlation (DIC) (2)
- Digitale Bildkorrelation (DIC) (2)
- Drop test (2)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (5)
- 8.0 Abteilungsleitung und andere (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 8.5 Röntgenbildgebung (2)
- 9 Komponentensicherheit (2)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
Eingeladener Vortrag
- nein (23)
Rückführung im Prüfwesen
(2003)
Langzeit-Monitoring an den Spannbetonbrücken des neuen Hauptbahnhofs Berlin (Lehrter Bahnhof)
(2008)
Spannbetonbrücken des neuen Hauptbahnhofs in Berlin, die etwa 170 m lang sind und auf 12 Stützen ruhen, werden für viele Jahre mit einem Monitorsystem überwacht. Gemessen werden langzeitig auftretende Setzungen und Hebungen an den Auflagerpunkten. Für die Messungen wird ein hydrostatisches und ein laseroptisches System für die vertikalen Verformungen eingesetzt, daneben Neigungsmesser und Dehnungsaufnehmer (elektrische und faseroptische) sowie Temperatur-Sensoren. Für die Auswertung wird eine neuartige Symbiose von experimenteller und mechanisch-numerischer Analyse angewendet.
An der BAM wurde Anfang 1996 die GUM-konforme Ermittlung und Angabe der Unsicherheit quantitativer Prüfergebnisse eingeführt. Nach einem kurzen Überblick über die wesentlichen Schritte und die bisherigen Erfahrungen wird die Ermittlung der Unsicherheit an Beispielen aus zwei Schwerpunktsbereichen der Prüftätigkeit der BAM vorgestellt: atomspektrometrische Analyse anorganischer Materialien und mechanisch-technologische Werkstoffprüfung. Abschließend wird ein Ausblick auf die Ermittlung der Unsicherheit qualitativer Prüfergebnisse gegeben. Diese Arbeit ist ein ergänzender Beitrag zur Thematik des tm-Sonderheftes über GUM-konforme Auswertung von Messungen, das im Januar 2001 erschienen ist.
At BAM, GUM-compliant evaluation and expression of uncertainty for quantitative test results was introduced in early 1996. After a brief overview of essential steps and experience so far, uncertainty evaluation is presented for examples from two main fields of BAM´s testing activities: analysis of inorganic materials by atomic spectrometry and mechanical materials testing using tensile/compression testing machines. Finally, an outlook is given on the evaluation of uncertainty for qualitative test results. This paper is a supplementary contribution to the topic of the tm special edition on GUM-compliant evaluation of measurements published January 2001.
Embedded conventional fibre Bragg grating (FBG) sensors with acrylate coating have been chosen for monitoring novel textile-reinforced composite materials with a complicated wavy structure as a result of reinforcing textures. Problems of monitoring this type of material occur due to the harsh fabrication technology of the composite and its complicated structure. Embedded fibre sensors are exposed to the influence of transverse and point-wise deformations. To what extent will these effects influence the measurement signal of a sensor? Temperature cycles, tension and vibration tests were carried out to answer this question. Transverse and point-wise deformation and micromechanical indentation tests on non-embedded FBG sensors were carried out to clarify the reliability of recorded signals.
VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF
(2002)
Messtechnik und Sensorik
(2014)
Aufgabe der Messtechnik ist die experimentelle Bestimmung quantitativ erfassbarer Größen in Wissenschaft und Technik. Für die Ingenieurwissenschaften liefert die Mess- und Prüftechnik Unterlagen zur Optimierung der Entwicklung, Konstruktion und Fertigung von Bauteilen und technischen Systemen sowie zur Beurteilung der Eigenschaften, Funktion, Qualität und Zuverlässigkeit technischer Produkte.
In this work an air-based sensor network for the localization of persons at extensive areas is presented. The developed network consists of a localization device which the person is wearing (BodyGuard-System), a mobile relay station in the air, and a base station. All three parts communicate with the same radio chip. The BodyGuard-System is an inertial navigation system which was developed for localization in difficult environments with high accuracy and low measurement uncertainty. To increase the range of the system, a multi-hop network was built up. The measured data of the BodyGuard-System and the mobile relay station is visualized on a PC in the base station. This multi-hop network is necessary for example for fire department missions.