Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (11)
- Beitrag zu einem Sammelband (6)
- Vortrag (5)
- Zeitschriftenartikel (3)
- Buchkapitel (3)
- Handbuch (1)
Sprache
- Englisch (29) (entfernen)
Referierte Publikation
- nein (29) (entfernen)
Schlagworte
- Messtechnik (3)
- Sensorik (3)
- Structural health monitoring (3)
- Monitoring (2)
- Accelerometer (1)
- Air-based (1)
- Application (1)
- Berlin Main Station (1)
- Bridges (1)
- Characterisation (1)
- Condition monitoring (1)
- Data processing (1)
- Data-fusion (1)
- Defect evaluation (1)
- Differential displacements (1)
- Digital image correlation (1)
- Digital image correlation (DIC) (1)
- Digitale Bildkorrelation (DIC) (1)
- Drop test (1)
- Dynamic testing (1)
- Dynamische Tests (1)
- Experimental-analytical symbiosis (1)
- Fibre-optic sensor (1)
- Hazardous scenarios (1)
- Hydraulic levelling system (1)
- Lagrangian Multipliers (1)
- Laser-based displacement measuring system (1)
- Localization (1)
- Long-term monitoring (1)
- Materials evaluation (1)
- Measurement Methods for Composition and Structure (1)
- Measurement Methods for Material Performance, Modelling and Simulation Methods (1)
- Measurement Methods for Material Properties (1)
- Mesh routing (1)
- Multi-hop (1)
- Multi-sensor system (1)
- Non-destructive testing (1)
- Optical Fibres (1)
- Plastic optical fibres (1)
- Reliability (1)
- Safety management (1)
- Sensing (1)
- Sensors (1)
- Spannungs-Dehnungs-Kurve (1)
- Specification (1)
- Split Hopkinson pressure bar (SHPB) (1)
- Standard (1)
- Standardization (1)
- Standards (1)
- Strain (1)
- Strain measurements (1)
- Stress-strain curve (1)
- Structural modelling (1)
- Structured light scanning (SLS) (1)
- Temperature (1)
- Temperature behavior (1)
- Testing (1)
- WSN (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (5)
VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF
(2002)
In this work an air-based sensor network for the localization of persons at extensive areas is presented. The developed network consists of a localization device which the person is wearing (BodyGuard-System), a mobile relay station in the air, and a base station. All three parts communicate with the same radio chip. The BodyGuard-System is an inertial navigation system which was developed for localization in difficult environments with high accuracy and low measurement uncertainty. To increase the range of the system, a multi-hop network was built up. The measured data of the BodyGuard-System and the mobile relay station is visualized on a PC in the base station. This multi-hop network is necessary for example for fire department missions.
Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station.
With more than 180.000 engineers and scientists VDI Association of German Engineers and VDE Association for Electrical, Electronic & Information Technologies are belonging to the major technical and scientific associations in Europe. Both organizations promote the advancement of technology and among other things by developing recognized technical regulations as national and international standards. Since 2011 Technical Committee 2.15 Optical Measuring Methods for Structure Analysis and Monitoring as a common committee of both organizations is working among other things on the development of standards for optical measuring and testing methods. The committee consists of 27 members representing industrial users, system manufacturers, research institutes and universities. Currently the committee is drafting the new standard VDI/VDE 2626 Part 1 - Optical measuring procedures – Image correlation methods – Basics and equipment, which will be introduced in this presentation.
Draft VDI/VDE 2626 Part 1 describes practical acceptance and reverification procedures for the evaluation of the accuracy of optical measuring systems based on digital image correlation (DIC) methods. The document applies to DIC measurement systems used a) for full-field determination of two- or three-dimensional displacement of surfaces, and b) for
full-field determination of the elongation or strain of surfaces. The standard describes quality parameters as well as methods and reference objects for their determination. The quality parameters serve to specify DIC systems, and to compare different systems. They are equally suitable a) for acceptance tests as well as b) for reverification of DIC systems within the framework of a quality management system.
The acceptance test is used to determine whether the DIC system complies with the quality parameter limits specified by the manufacturer, or with contractually agreed limits by the manufacturer and user, respectively. For this test the quality parameters zero-displacement error, zero-strain error, and displacement error are defined and used. Zero-displacement error and zero-strain error describe minimum measurement uncertainties of the DIC system a user has to reckon with. They are influenced by different uncertainty contributions. The quality parameter displacement error is used to check the ability of the DIC system to determine absolute displacements within the measurement volume and to confirm the traceability of this measurement to the SI system.
Reverification of DIC systems serves to ensure long-term compliance with specified limits for the quality parameters. By comparing the results of successive reverification measurements of the quality parameters used for the acceptance test, it is possible to analyze trends with respect to changes in DIC system characteristics.
Piezoresistive accelerometers use a strain-sensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending of the beam, which produces a change of electrical resistance proportional to the applied acceleration.
Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity.
This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g.
This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C.
Embedded sensors
(2013)
This chapter introduces and describes the concept of structural health monitoring (SHM) to engineers and designers of technical structures, and to the owners/operators of such structures. It formulates general principles for integrating and implementing measurement and signal processing technologies in the context of SHM to diagnose the condition, performance and health of a technical structure. Information and recommended methods for designing instrumentation, data acquisition, data processing and data analysis for any SHM application are offered.
This chapter summarizes the state of the art and current developments of guidelines for structural health monitoring (SHM) and performance control. Technical guidelines and standards for condition monitoring and technical diagnostics of rotary machines and for non-destructive testing are not reviewed in this chapter.
Sensing with optical fibres
(2014)
Starting from the first patent of a fibre optic sensor in 1967, fibre optic sensing has become a success story throughout the world. Today, fibre optic point sensors and continuous distributed fibre optics sensor systems allow the measurement of nearly all physical quantities and contribute to higher safety levels in many industrial sectors. Monitoring of pipelines, power cables, lightweight and civil engineering structures, and of ground movements are heading the hit list of applications. Standardization in this field is of paramount relevance and brings to light some of the challenges now faced by IEC SC (Subcommittee) 86C/WG (Working Group) 2: Fibre optic sensors.
The absolute detection of a gap distance of loose and ftxed extrinsic Fabry-Perot interferometer (EFPI) sensors with conventional measurement Systems is not possible. Due to this EFPI-sensors were deemed to be unfit for distance determination in comparision with FBG sensors. With the conventional measurement method a continous measurement of the EFPIsensors was necessary. Otherwise data about the distance change was lost. Additional it is necessary to detect the tumaround points in the interference signal with 100%. This made it worse for the analysis and the use of the sensor. At BAM Federal Institute for Materials Research and Testing a measurement System called “EFPI-Scan” is developed which can measure the absolute gap distance of four connected EFPI-sensors synchronous. Every measurement channel is temperature independetn and long term stable. Test measurements showed a deviation of maximum ±1 gm per hour. Furthermore it is possible to measure with different measurement modes (abolute, relative and a combination of both). Special emphasis should be placed to the absolute measurement accuracy of ± 5 pm at a gap distance determination ftom 40 up to 4000 pm.
Standardization in fibre-optic sensing for structural safety - activities in the ISHMII and IEC
(2015)
Fiber-optic sensors are increasingly established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations to enhance the operational performance of aged structures or to monitor the structural behavior of safety-relevant structures or their components. However, there are some barriers in use due to a lack of extensive standardization of fiber-optic sensors. This leads very often to restraints in the users community. The paper shows the status in international standardization of fiber-optic sensors as well as current activities in leading institutions such as IEC and ISHMII and others with the purpose of providing relevant standards for a broader use of selected fiber-optic sensor technologies.
The stress vs. strain curve of materials is affected the rate of imposed straining. Among the methods for dynamic testing the technique known as 'split Hopkinson pressure bar' (SHPB) has evolved into the most widely used one to exert high-speed straining. The theory behind it comprises simple equations to compute stress and strain. The reliability of the strain analysis can be assessed by digital image correlation (DIC). The present results indicate that the visually observed strain is smaller than predicted by theory.
High quality tubular products are essential to the oil and gas industry. Quality control during their production focuses on the non-destructive detection of surface defects. The structured light technique is a candidate for the challenge to detect, monitor and evaluate such defects in real-time.
In the present study the automatic processing of structured light measurements is performed and validated. The algorithm for the automatic Analysis of inspection data has an advantage over current data evaluation methods based on individual assessments of operators.