Standardization in fibre-optic sensing for structural safety - activities in the ISHMII and IEC
(2015)
Fiber-optic sensors are increasingly established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations to enhance the operational performance of aged structures or to monitor the structural behavior of safety-relevant structures or their components. However, there are some barriers in use due to a lack of extensive standardization of fiber-optic sensors. This leads very often to restraints in the users community. The paper shows the status in international standardization of fiber-optic sensors as well as current activities in leading institutions such as IEC and ISHMII and others with the purpose of providing relevant standards for a broader use of selected fiber-optic sensor technologies.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Mit einem auf Lagrange-Multipiikator-Tests basierenden Monitoring von Brücken ist es gelungen, in Belastungsversuchen an einer Holzbrücke (7,25 m Spannweite), an der relativ kleine Schädigungen künstlich herbeigeführt worden waren, die Zuverlässigkeit dieser Art des Monitorings zu bestätigen. Ausgangspunkte waren Messung von Durchbiegungen sowie Krümmungen und die Zusammenführung der jeweiligen Regression mit Nebenbedingungen, die den mechanischen Bedingungen gehorchen, unter Einschluss von Lagrange-Multiplikatoren, die sich als brauchbare Testparameter erwiesen.
The stress vs. strain curve of materials is affected the rate of imposed straining. Among the methods for dynamic testing the technique known as 'split Hopkinson pressure bar' (SHPB) has evolved into the most widely used one to exert high-speed straining. The theory behind it comprises simple equations to compute stress and strain. The reliability of the strain analysis can be assessed by digital image correlation (DIC). The present results indicate that the visually observed strain is smaller than predicted by theory.