- Drop test (1)
VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF
(2002)
The absolute detection of a gap distance of loose and ftxed extrinsic Fabry-Perot interferometer (EFPI) sensors with conventional measurement Systems is not possible. Due to this EFPI-sensors were deemed to be unfit for distance determination in comparision with FBG sensors. With the conventional measurement method a continous measurement of the EFPIsensors was necessary. Otherwise data about the distance change was lost. Additional it is necessary to detect the tumaround points in the interference signal with 100%. This made it worse for the analysis and the use of the sensor. At BAM Federal Institute for Materials Research and Testing a measurement System called “EFPI-Scan” is developed which can measure the absolute gap distance of four connected EFPI-sensors synchronous. Every measurement channel is temperature independetn and long term stable. Test measurements showed a deviation of maximum ±1 gm per hour. Furthermore it is possible to measure with different measurement modes (abolute, relative and a combination of both). Special emphasis should be placed to the absolute measurement accuracy of ± 5 pm at a gap distance determination ftom 40 up to 4000 pm.
Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station.
Standardization in fibre-optic sensing for structural safety - activities in the ISHMII and IEC
(2015)
Fiber-optic sensors are increasingly established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations to enhance the operational performance of aged structures or to monitor the structural behavior of safety-relevant structures or their components. However, there are some barriers in use due to a lack of extensive standardization of fiber-optic sensors. This leads very often to restraints in the users community. The paper shows the status in international standardization of fiber-optic sensors as well as current activities in leading institutions such as IEC and ISHMII and others with the purpose of providing relevant standards for a broader use of selected fiber-optic sensor technologies.
The stress vs. strain curve of materials is affected the rate of imposed straining. Among the methods for dynamic testing the technique known as 'split Hopkinson pressure bar' (SHPB) has evolved into the most widely used one to exert high-speed straining. The theory behind it comprises simple equations to compute stress and strain. The reliability of the strain analysis can be assessed by digital image correlation (DIC). The present results indicate that the visually observed strain is smaller than predicted by theory.