Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT.
In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Mit einem auf Lagrange-Multipiikator-Tests basierenden Monitoring von Brücken ist es gelungen, in Belastungsversuchen an einer Holzbrücke (7,25 m Spannweite), an der relativ kleine Schädigungen künstlich herbeigeführt worden waren, die Zuverlässigkeit dieser Art des Monitorings zu bestätigen. Ausgangspunkte waren Messung von Durchbiegungen sowie Krümmungen und die Zusammenführung der jeweiligen Regression mit Nebenbedingungen, die den mechanischen Bedingungen gehorchen, unter Einschluss von Lagrange-Multiplikatoren, die sich als brauchbare Testparameter erwiesen.
Innovative structural damage detection of bridges by least squares adjustment with constraints
(2015)
Innovative structural damage detection of bridges by least squares adjustment with constraints
(2016)
Long-term monitoring of bridges requires the early detection of spreading damage because very often the damage is not really visible. For many decades engineers and scientists relayed on dynamic methods especially modal ones. However, after fundamental tests by the U.S. FHWA in 1993, it became evident that more successful methods should be developed, but no innovation really happened. A substantial innovative detection method started four years ago from Lagrange Multiplier Testing which eventually resulted in experimental verification based on measurement of deflection and curvature of the bridge beam and together the methodological combination of both.
Health monitoring von größeren Strukturen erfordert die Betrachtung der gesamten Struktur, indem sowohl jener Bereich, der experimentell behandelt wird, als auch derjenige, der einer analytischen mechanischen Untersuchung unterzogen wird, in einem Gesamtzusammenhang erfasst wird. Die umfassende Behandlung des Problems gelingt dann in einer Gesamtmatrix, die im Beitrag vorgestellt wird. Auf eine Erweiterung der Methode zur Detektierung anwachsender Schädigungen wird hingewiesen.