Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (23)
- Beitrag zu einem Tagungsband (16)
- Beitrag zu einem Sammelband (9)
- Buchkapitel (7)
- Zeitschriftenartikel (5)
- Posterpräsentation (3)
- Handbuch (2)
- Forschungsbericht (2)
- Sonstiges (1)
Referierte Publikation
- nein (68) (entfernen)
Schlagworte
- Sensorik (7)
- Messtechnik (6)
- Structural health monitoring (4)
- Monitoring (3)
- Maschinenbau (2)
- Schadensdetektion (2)
- Accelerometer (1)
- Adaptives mathematisches Modell (1)
- Additive Fertigung (1)
- Air-based (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (4)
- 8.0 Abteilungsleitung und andere (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 8.5 Röntgenbildgebung (1)
- 9 Komponentensicherheit (1)
- 9.5 Tribologie und Verschleißschutz (1)
- VP Vizepräsident (1)
- VP.1 eScience (1)
Eingeladener Vortrag
- nein (23)
Entwicklung von Verfahren zur Beurteilung der Bildqualität von Radioskopie-Systemen aus der zerstörungsfreien Werkstoffprüfung nach einheitlichen, objektiven und quantitativen Kriterien, Betrachtung der physikalischen Grundlagen der Strahlungserzeugung, Strahlenreliefenstehung und -umwandlung sowie der damit verbundenen Einflussgrößen auf die Bildqualität. Herleitung und Definition von Bildqualitätsmerkmalen (radiographische Kriterien, Kenngrößen aus der Systemtheorie und allgemeine optische Abbildungseigenschaften), Beschreibung wichtiger Zusammenhänge zwischen einzelnen Bildqualitätsmerkmalen und bestimmten Geräteparametern.
VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF
(2002)
With more than 180.000 engineers and scientists VDI Association of German Engineers and VDE Association for Electrical, Electronic & Information Technologies are belonging to the major technical and scientific associations in Europe. Both organizations promote the advancement of technology and among other things by developing recognized technical regulations as national and international standards. Since 2011 Technical Committee 2.15 Optical Measuring Methods for Structure Analysis and Monitoring as a common committee of both organizations is working among other things on the development of standards for optical measuring and testing methods. The committee consists of 27 members representing industrial users, system manufacturers, research institutes and universities. Currently the committee is drafting the new standard VDI/VDE 2626 Part 1 - Optical measuring procedures – Image correlation methods – Basics and equipment, which will be introduced in this presentation.
Draft VDI/VDE 2626 Part 1 describes practical acceptance and reverification procedures for the evaluation of the accuracy of optical measuring systems based on digital image correlation (DIC) methods. The document applies to DIC measurement systems used a) for full-field determination of two- or three-dimensional displacement of surfaces, and b) for
full-field determination of the elongation or strain of surfaces. The standard describes quality parameters as well as methods and reference objects for their determination. The quality parameters serve to specify DIC systems, and to compare different systems. They are equally suitable a) for acceptance tests as well as b) for reverification of DIC systems within the framework of a quality management system.
The acceptance test is used to determine whether the DIC system complies with the quality parameter limits specified by the manufacturer, or with contractually agreed limits by the manufacturer and user, respectively. For this test the quality parameters zero-displacement error, zero-strain error, and displacement error are defined and used. Zero-displacement error and zero-strain error describe minimum measurement uncertainties of the DIC system a user has to reckon with. They are influenced by different uncertainty contributions. The quality parameter displacement error is used to check the ability of the DIC system to determine absolute displacements within the measurement volume and to confirm the traceability of this measurement to the SI system.
Reverification of DIC systems serves to ensure long-term compliance with specified limits for the quality parameters. By comparing the results of successive reverification measurements of the quality parameters used for the acceptance test, it is possible to analyze trends with respect to changes in DIC system characteristics.
VDE-VDI-Richtlinie 5570
(2003)
The stress vs. strain curve of materials is affected the rate of imposed straining. Among the methods for dynamic testing the technique known as 'split Hopkinson pressure bar' (SHPB) has evolved into the most widely used one to exert high-speed straining. The theory behind it comprises simple equations to compute stress and strain. The reliability of the strain analysis can be assessed by digital image correlation (DIC). The present results indicate that the visually observed strain is smaller than predicted by theory.
Standardization in fibre-optic sensing for structural safety - activities in the ISHMII and IEC
(2015)
Fiber-optic sensors are increasingly established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations to enhance the operational performance of aged structures or to monitor the structural behavior of safety-relevant structures or their components. However, there are some barriers in use due to a lack of extensive standardization of fiber-optic sensors. This leads very often to restraints in the users community. The paper shows the status in international standardization of fiber-optic sensors as well as current activities in leading institutions such as IEC and ISHMII and others with the purpose of providing relevant standards for a broader use of selected fiber-optic sensor technologies.
Sensing with optical fibres
(2014)
Starting from the first patent of a fibre optic sensor in 1967, fibre optic sensing has become a success story throughout the world. Today, fibre optic point sensors and continuous distributed fibre optics sensor systems allow the measurement of nearly all physical quantities and contribute to higher safety levels in many industrial sectors. Monitoring of pipelines, power cables, lightweight and civil engineering structures, and of ground movements are heading the hit list of applications. Standardization in this field is of paramount relevance and brings to light some of the challenges now faced by IEC SC (Subcommittee) 86C/WG (Working Group) 2: Fibre optic sensors.
Rückführung im Prüfwesen
(2003)
This chapter introduces and describes the concept of structural health monitoring (SHM) to engineers and designers of technical structures, and to the owners/operators of such structures. It formulates general principles for integrating and implementing measurement and signal processing technologies in the context of SHM to diagnose the condition, performance and health of a technical structure. Information and recommended methods for designing instrumentation, data acquisition, data processing and data analysis for any SHM application are offered.
Meßtechnik und Sensorik
(2007)
Messtechnik und Sensorik
(2014)
Aufgabe der Messtechnik ist die experimentelle Bestimmung quantitativ erfassbarer Größen in Wissenschaft und Technik. Für die Ingenieurwissenschaften liefert die Mess- und Prüftechnik Unterlagen zur Optimierung der Entwicklung, Konstruktion und Fertigung von Bauteilen und technischen Systemen sowie zur Beurteilung der Eigenschaften, Funktion, Qualität und Zuverlässigkeit technischer Produkte.
Messtechnik und Sensorik
(2018)
Messtechnik und Sensorik
(2011)
Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station.
Langzeit-Monitoring an den Spannbetonbrücken des neuen Hauptbahnhofs Berlin (Lehrter Bahnhof)
(2008)
Spannbetonbrücken des neuen Hauptbahnhofs in Berlin, die etwa 170 m lang sind und auf 12 Stützen ruhen, werden für viele Jahre mit einem Monitorsystem überwacht. Gemessen werden langzeitig auftretende Setzungen und Hebungen an den Auflagerpunkten. Für die Messungen wird ein hydrostatisches und ein laseroptisches System für die vertikalen Verformungen eingesetzt, daneben Neigungsmesser und Dehnungsaufnehmer (elektrische und faseroptische) sowie Temperatur-Sensoren. Für die Auswertung wird eine neuartige Symbiose von experimenteller und mechanisch-numerischer Analyse angewendet.
Mit einem auf Lagrange-Multipiikator-Tests basierenden Monitoring von Brücken ist es gelungen, in Belastungsversuchen an einer Holzbrücke (7,25 m Spannweite), an der relativ kleine Schädigungen künstlich herbeigeführt worden waren, die Zuverlässigkeit dieser Art des Monitorings zu bestätigen. Ausgangspunkte waren Messung von Durchbiegungen sowie Krümmungen und die Zusammenführung der jeweiligen Regression mit Nebenbedingungen, die den mechanischen Bedingungen gehorchen, unter Einschluss von Lagrange-Multiplikatoren, die sich als brauchbare Testparameter erwiesen.
Karriere in der Forschung
(2014)
This chapter summarizes the state of the art and current developments of guidelines for structural health monitoring (SHM) and performance control. Technical guidelines and standards for condition monitoring and technical diagnostics of rotary machines and for non-destructive testing are not reviewed in this chapter.
Fibre Optic Sensing
(2013)
Experimental Validation Technique for Strain Transfer Characterization of Fibre Optic Strain Sensors
(2011)
Health monitoring von größeren Strukturen erfordert die Betrachtung der gesamten Struktur, indem sowohl jener Bereich, der experimentell behandelt wird, als auch derjenige, der einer analytischen mechanischen Untersuchung unterzogen wird, in einem Gesamtzusammenhang erfasst wird. Die umfassende Behandlung des Problems gelingt dann in einer Gesamtmatrix, die im Beitrag vorgestellt wird. Auf eine Erweiterung der Methode zur Detektierung anwachsender Schädigungen wird hingewiesen.