Ergebnisunsicherheit im Prüfwesen - eine Einführung in Systematik und praktische Vorgehensweisen
(2005)
VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF
(2002)
In diesem Paper wird ein absolut messendes faseroptisches Messsystem zur Bestimmung des Gap-Abstandes von niedrig reflektierenden losen und festen extrinsischer Fabry-Pérot Interferometer (EFPI) vorgestellt. Die häufigste Methode zur Bestimmung von Dehnungen oder Bewegungen durch EFPI-Sensoren ist eine kontinuierliche relative Ermittlung einer Veränderung mit einer nachträglichen Auswertung. Unterbrechungen in der Datenerfassung oder Fehler bei der Interferenzstreifen-Auswertung führen zu einer nicht abschätzbaren Messunsicherheit. Damit war es bis dato nicht möglich, eine absolute Veränderung von eingesetzten EFPI-Sensoren zu bestimmen. Mit dem an der BAM entwickelten Verfahren, ist dies jetzt möglich, die absolute Veränderung zu bestimmen. Dieses System namens 'EFPI-Scan' wird in dem Papier dargestellt werden.
Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station.
Piezoresistive accelerometers use a strain-sensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending of the beam, which produces a change of electrical resistance proportional to the applied acceleration.
Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity.
This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g.
This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C.
The absolute detection of a gap distance of loose and ftxed extrinsic Fabry-Perot interferometer (EFPI) sensors with conventional measurement Systems is not possible. Due to this EFPI-sensors were deemed to be unfit for distance determination in comparision with FBG sensors. With the conventional measurement method a continous measurement of the EFPIsensors was necessary. Otherwise data about the distance change was lost. Additional it is necessary to detect the tumaround points in the interference signal with 100%. This made it worse for the analysis and the use of the sensor. At BAM Federal Institute for Materials Research and Testing a measurement System called “EFPI-Scan” is developed which can measure the absolute gap distance of four connected EFPI-sensors synchronous. Every measurement channel is temperature independetn and long term stable. Test measurements showed a deviation of maximum ±1 gm per hour. Furthermore it is possible to measure with different measurement modes (abolute, relative and a combination of both). Special emphasis should be placed to the absolute measurement accuracy of ± 5 pm at a gap distance determination ftom 40 up to 4000 pm.
Standardization in fibre-optic sensing for structural safety - activities in the ISHMII and IEC
(2015)
Fiber-optic sensors are increasingly established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations to enhance the operational performance of aged structures or to monitor the structural behavior of safety-relevant structures or their components. However, there are some barriers in use due to a lack of extensive standardization of fiber-optic sensors. This leads very often to restraints in the users community. The paper shows the status in international standardization of fiber-optic sensors as well as current activities in leading institutions such as IEC and ISHMII and others with the purpose of providing relevant standards for a broader use of selected fiber-optic sensor technologies.
Die ständige Überwachung von Konstruktionen während ihrer Lebenszeit ist eine bedeutsame Aufgabe, die Gegenstand vielzähliger Forschungsaktivitäten ist. Unter dem Aspekt der Nachhaltigkeit ist die Verlängerung der Nutzungsdauer bestehender Konstruktionen von unschätzbarem Wert, sowohl aus finanziellen Gründen als auch unter dem Gesichtspunkt der Erhaltung der gebauten Umwelt und des Denkmalschutzes.Bei allen Erfolgen der Projekte zur Bauwerkserhaltung ist die Frage, wie entstehende Schädigungen rechtzeitig erkannt werden können, auch wenn sie erst geringfügig sind, nicht befriedigend beantwortet worden. In diesem Beitrag wird eine neue Methode zur Detektierung von Strukturschädigungenvorgestellt. Diese beruht auf einer integrierten Auswertung von Messwerten verschiedener Sensoren nach der Methode der kleinsten Quadrate sowie der Interpretation der dabei auftretenden Langrange-Multiplikatoren.Diese Methode der Schädigungsanalyse wird anhand eines numerischen Beispiels aus einemVier-Punkt-Biegeversuchmit einem Verbundträgernäher erläutert.
Mit einem auf Lagrange-Multipiikator-Tests basierenden Monitoring von Brücken ist es gelungen, in Belastungsversuchen an einer Holzbrücke (7,25 m Spannweite), an der relativ kleine Schädigungen künstlich herbeigeführt worden waren, die Zuverlässigkeit dieser Art des Monitorings zu bestätigen. Ausgangspunkte waren Messung von Durchbiegungen sowie Krümmungen und die Zusammenführung der jeweiligen Regression mit Nebenbedingungen, die den mechanischen Bedingungen gehorchen, unter Einschluss von Lagrange-Multiplikatoren, die sich als brauchbare Testparameter erwiesen.
The stress vs. strain curve of materials is affected the rate of imposed straining. Among the methods for dynamic testing the technique known as 'split Hopkinson pressure bar' (SHPB) has evolved into the most widely used one to exert high-speed straining. The theory behind it comprises simple equations to compute stress and strain. The reliability of the strain analysis can be assessed by digital image correlation (DIC). The present results indicate that the visually observed strain is smaller than predicted by theory.