Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (23)
- Vortrag (23)
- Zeitschriftenartikel (19)
- Beitrag zu einem Sammelband (9)
- Buchkapitel (7)
- Posterpräsentation (3)
- Handbuch (2)
- Forschungsbericht (2)
- Sonstiges (1)
Sprache
- Englisch (45)
- Deutsch (43)
- Mehrsprachig (1)
Schlagworte
- Sensorik (7)
- Messtechnik (6)
- Monitoring (5)
- Structural health monitoring (5)
- Application (2)
- Ausgleichsrechnung (2)
- Characterisation (2)
- Digital image correlation (DIC) (2)
- Digitale Bildkorrelation (DIC) (2)
- Drop test (2)
- Dynamic testing (2)
- Dynamische Tests (2)
- Maschinenbau (2)
- Polymer optical fiber (2)
- Schadensdetektion (2)
- Schadensfrüherkennung (2)
- Spannungs-Dehnungs-Kurve (2)
- Split Hopkinson pressure bar (SHPB) (2)
- Standard (2)
- Strain (2)
- Stress-strain curve (2)
- Temperature (2)
- Zustandsüberwachung (2)
- Accelerometer (1)
- Adaptives mathematisches Modell (1)
- Additive Fertigung (1)
- Additive Manufacturing (1)
- Ageing (1)
- Aging (1)
- Air-based (1)
- Artificial intelligence (1)
- Bauelement (1)
- Bauwerk (1)
- Berlin Main Station (1)
- Bildverarbeitung (1)
- Bridges (1)
- Brillouin scattering (1)
- Brillouin-Streuung (1)
- Chemiluminescence (1)
- Chemiluminescence (CL) (1)
- Condition monitoring (1)
- Construction (1)
- Curve fitting (1)
- Damage (1)
- Damage detection (1)
- Damage detection of bridges (1)
- Data processing (1)
- Data science (1)
- Data-fusion (1)
- Datenwissenschaft (1)
- Defect evaluation (1)
- Degradation (1)
- Dehnungssensor (1)
- Determination procedure (1)
- Differential displacements (1)
- Digital image correlation (1)
- Digitalisierung (1)
- Digitization (1)
- Distributed sensor (1)
- Elementanalytik (1)
- Energietechnik (1)
- Environment (1)
- Ergebnisunsicherheit (1)
- Experimental-analytical symbiosis (1)
- FBG sensors (1)
- Faseroptischer Sensor (1)
- Fatigue (1)
- Fertigung (1)
- Fiber bragg grating (1)
- Fiber optic sensor (1)
- Fiber-optic sensor (1)
- Fibre-optic sensor (1)
- Hazardous scenarios (1)
- Heiz- und Klimatechnik (1)
- High speed stereo photogrammetry (1)
- Hydraulic levelling system (1)
- In-situ Process Monitoring (1)
- Intelligentes Geotextil (1)
- Kalibrierlösungen (1)
- Kernreaktor (1)
- Konstruktion (1)
- Künstliche Intelligenz (1)
- Lagrange multiplier (1)
- Lagrange multiplier test (1)
- Lagrange-Multiplikator (1)
- Lagrangesche Methode (1)
- Lagrangian Multipliers (1)
- Langzeit-Monitoring (1)
- Laser-based displacement measuring system (1)
- Localization (1)
- Long-term monitoring (1)
- Magnetic field (1)
- Magnetostrictive metal coating (1)
- Materials evaluation (1)
- Measurement Methods for Composition and Structure (1)
- Measurement Methods for Material Performance, Modelling and Simulation Methods (1)
- Measurement Methods for Material Properties (1)
- Measurement reliability (1)
- Measurement uncertainty (1)
- Mesh routing (1)
- Mess- und Regelungstechnik (1)
- Messunsicherheit (1)
- Modellgestützte Messverfahren (1)
- Multi-hop (1)
- Multi-sensor system (1)
- Non-destructive Materials (1)
- Non-destructive testing (1)
- Normung Roadmap (1)
- Numerical simulation (1)
- Optical Fibres (1)
- Optical digitization (1)
- Optical transmission stability (1)
- Plastic optical fibres (1)
- Polymer optical fibers (POFs) (1)
- Polymeroptische Faser (1)
- Process development (1)
- Qualitative test result (1)
- Quantitative test result (1)
- Reliability (1)
- Result uncertainty (1)
- Röntgengrobstrukturanalyse (1)
- Safety (1)
- Safety management (1)
- Schädigung (1)
- Self-diagnostic fiber optical sensor (1)
- Sensing (1)
- Sensors (1)
- Smart geotextiles (1)
- Specification (1)
- Standardisation (1)
- Standardization (1)
- Standardization roadmap (1)
- Standards (1)
- Steel sheet container (1)
- Strain measurements (1)
- Strain sensor (1)
- Structural Health Monitoring (1)
- Structural health (1)
- Structural modelling (1)
- Structured light scanning (SLS) (1)
- Strukturschädigung (1)
- Temperature behavior (1)
- Testing (1)
- Textile-reinforced composites (1)
- Thermo-oxidative stability (1)
- Transparency (1)
- Verfahrenstechnik (1)
- Vergleich von Modell und Messung (1)
- Verteilter Sensor (1)
- WSN (1)
- Werkstoffprüfmaschinen (1)
- Zerstörungsfreie Prüfung (1)
- Zugprüfung (1)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (5)
- 8.0 Abteilungsleitung und andere (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 8.5 Röntgenbildgebung (2)
- 9 Komponentensicherheit (2)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 8.3 Thermografische Verfahren (1)
- 9.3 Schweißtechnische Fertigungsverfahren (1)
- 9.4 Integrität von Schweißverbindungen (1)
- 9.5 Tribologie und Verschleißschutz (1)
- S Qualitätsinfrastruktur (1)
- S.0 Abteilungsleitung und andere (1)
- VP Vizepräsident (1)
- VP.1 eScience (1)
Eingeladener Vortrag
- nein (23)
Ergebnisunsicherheit im Prüfwesen- Eine Einführung in Systematik und praktische Vorgehensweisen
(2005)
Ergebnisunsicherheit im Prüfwesen - eine Einführung in Systematik und praktische Vorgehensweisen
(2005)
The thermo-oxidative stability of commercially available polymer optical fibers (POFs) and their components (cores and claddings) was investigated. All the bare POFs (core and cladding only) studied here were based on poly(methyl methacrylate) (PMMA) core. The fibers were exposed to 100 °C/low humidity for about 4200 h. Chemiluminescence (CL) technique was applied to investigate the thermo-oxidative stability and for measuring the transmission loss during exposure a prototype device called multiplexer was used. POFs exhibited variation in thermo-oxidative stability although they possessed identical core material PMMA. This was due to difference in the chemical compositions of claddings. Claddings were more susceptible to the thermo-oxidative degradation compared to cores. The thermo-oxidative degradation of both the cladding and the core was found in POFs as a result of climatic exposure. POFs showed an early drop-off followed by a slow decline of transmission. The early drop-off of transmission was attributed to physical changes like thermal expansion and the slow decline of transmission to chemical changes like oxidative degradation of POFs. A good linear relationship between optical transmission stability and thermo-oxidative stability of POFs was established from these studies.
Meßtechnik und Sensorik
(2007)
Entwicklung von Verfahren zur Beurteilung der Bildqualität von Radioskopie-Systemen aus der zerstörungsfreien Werkstoffprüfung nach einheitlichen, objektiven und quantitativen Kriterien, Betrachtung der physikalischen Grundlagen der Strahlungserzeugung, Strahlenreliefenstehung und -umwandlung sowie der damit verbundenen Einflussgrößen auf die Bildqualität. Herleitung und Definition von Bildqualitätsmerkmalen (radiographische Kriterien, Kenngrößen aus der Systemtheorie und allgemeine optische Abbildungseigenschaften), Beschreibung wichtiger Zusammenhänge zwischen einzelnen Bildqualitätsmerkmalen und bestimmten Geräteparametern.
VDE-VDI-Richtlinie 5570
(2003)
Rückführung im Prüfwesen
(2003)
Langzeit-Monitoring an den Spannbetonbrücken des neuen Hauptbahnhofs Berlin (Lehrter Bahnhof)
(2008)
Spannbetonbrücken des neuen Hauptbahnhofs in Berlin, die etwa 170 m lang sind und auf 12 Stützen ruhen, werden für viele Jahre mit einem Monitorsystem überwacht. Gemessen werden langzeitig auftretende Setzungen und Hebungen an den Auflagerpunkten. Für die Messungen wird ein hydrostatisches und ein laseroptisches System für die vertikalen Verformungen eingesetzt, daneben Neigungsmesser und Dehnungsaufnehmer (elektrische und faseroptische) sowie Temperatur-Sensoren. Für die Auswertung wird eine neuartige Symbiose von experimenteller und mechanisch-numerischer Analyse angewendet.
An der BAM wurde Anfang 1996 die GUM-konforme Ermittlung und Angabe der Unsicherheit quantitativer Prüfergebnisse eingeführt. Nach einem kurzen Überblick über die wesentlichen Schritte und die bisherigen Erfahrungen wird die Ermittlung der Unsicherheit an Beispielen aus zwei Schwerpunktsbereichen der Prüftätigkeit der BAM vorgestellt: atomspektrometrische Analyse anorganischer Materialien und mechanisch-technologische Werkstoffprüfung. Abschließend wird ein Ausblick auf die Ermittlung der Unsicherheit qualitativer Prüfergebnisse gegeben. Diese Arbeit ist ein ergänzender Beitrag zur Thematik des tm-Sonderheftes über GUM-konforme Auswertung von Messungen, das im Januar 2001 erschienen ist.
At BAM, GUM-compliant evaluation and expression of uncertainty for quantitative test results was introduced in early 1996. After a brief overview of essential steps and experience so far, uncertainty evaluation is presented for examples from two main fields of BAM´s testing activities: analysis of inorganic materials by atomic spectrometry and mechanical materials testing using tensile/compression testing machines. Finally, an outlook is given on the evaluation of uncertainty for qualitative test results. This paper is a supplementary contribution to the topic of the tm special edition on GUM-compliant evaluation of measurements published January 2001.
Embedded conventional fibre Bragg grating (FBG) sensors with acrylate coating have been chosen for monitoring novel textile-reinforced composite materials with a complicated wavy structure as a result of reinforcing textures. Problems of monitoring this type of material occur due to the harsh fabrication technology of the composite and its complicated structure. Embedded fibre sensors are exposed to the influence of transverse and point-wise deformations. To what extent will these effects influence the measurement signal of a sensor? Temperature cycles, tension and vibration tests were carried out to answer this question. Transverse and point-wise deformation and micromechanical indentation tests on non-embedded FBG sensors were carried out to clarify the reliability of recorded signals.
VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF
(2002)
Messtechnik und Sensorik
(2014)
Aufgabe der Messtechnik ist die experimentelle Bestimmung quantitativ erfassbarer Größen in Wissenschaft und Technik. Für die Ingenieurwissenschaften liefert die Mess- und Prüftechnik Unterlagen zur Optimierung der Entwicklung, Konstruktion und Fertigung von Bauteilen und technischen Systemen sowie zur Beurteilung der Eigenschaften, Funktion, Qualität und Zuverlässigkeit technischer Produkte.
In this work an air-based sensor network for the localization of persons at extensive areas is presented. The developed network consists of a localization device which the person is wearing (BodyGuard-System), a mobile relay station in the air, and a base station. All three parts communicate with the same radio chip. The BodyGuard-System is an inertial navigation system which was developed for localization in difficult environments with high accuracy and low measurement uncertainty. To increase the range of the system, a multi-hop network was built up. The measured data of the BodyGuard-System and the mobile relay station is visualized on a PC in the base station. This multi-hop network is necessary for example for fire department missions.
In diesem Paper wird ein absolut messendes faseroptisches Messsystem zur Bestimmung des Gap-Abstandes von niedrig reflektierenden losen und festen extrinsischer Fabry-Pérot Interferometer (EFPI) vorgestellt. Die häufigste Methode zur Bestimmung von Dehnungen oder Bewegungen durch EFPI-Sensoren ist eine kontinuierliche relative Ermittlung einer Veränderung mit einer nachträglichen Auswertung. Unterbrechungen in der Datenerfassung oder Fehler bei der Interferenzstreifen-Auswertung führen zu einer nicht abschätzbaren Messunsicherheit. Damit war es bis dato nicht möglich, eine absolute Veränderung von eingesetzten EFPI-Sensoren zu bestimmen. Mit dem an der BAM entwickelten Verfahren, ist dies jetzt möglich, die absolute Veränderung zu bestimmen. Dieses System namens 'EFPI-Scan' wird in dem Papier dargestellt werden.
Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station.
Health monitoring von größeren Strukturen erfordert die Betrachtung der gesamten Struktur, indem sowohl jener Bereich, der experimentell behandelt wird, als auch derjenige, der einer analytischen mechanischen Untersuchung unterzogen wird, in einem Gesamtzusammenhang erfasst wird. Die umfassende Behandlung des Problems gelingt dann in einer Gesamtmatrix, die im Beitrag vorgestellt wird. Auf eine Erweiterung der Methode zur Detektierung anwachsender Schädigungen wird hingewiesen.
With more than 180.000 engineers and scientists VDI Association of German Engineers and VDE Association for Electrical, Electronic & Information Technologies are belonging to the major technical and scientific associations in Europe. Both organizations promote the advancement of technology and among other things by developing recognized technical regulations as national and international standards. Since 2011 Technical Committee 2.15 Optical Measuring Methods for Structure Analysis and Monitoring as a common committee of both organizations is working among other things on the development of standards for optical measuring and testing methods. The committee consists of 27 members representing industrial users, system manufacturers, research institutes and universities. Currently the committee is drafting the new standard VDI/VDE 2626 Part 1 - Optical measuring procedures – Image correlation methods – Basics and equipment, which will be introduced in this presentation.
Draft VDI/VDE 2626 Part 1 describes practical acceptance and reverification procedures for the evaluation of the accuracy of optical measuring systems based on digital image correlation (DIC) methods. The document applies to DIC measurement systems used a) for full-field determination of two- or three-dimensional displacement of surfaces, and b) for
full-field determination of the elongation or strain of surfaces. The standard describes quality parameters as well as methods and reference objects for their determination. The quality parameters serve to specify DIC systems, and to compare different systems. They are equally suitable a) for acceptance tests as well as b) for reverification of DIC systems within the framework of a quality management system.
The acceptance test is used to determine whether the DIC system complies with the quality parameter limits specified by the manufacturer, or with contractually agreed limits by the manufacturer and user, respectively. For this test the quality parameters zero-displacement error, zero-strain error, and displacement error are defined and used. Zero-displacement error and zero-strain error describe minimum measurement uncertainties of the DIC system a user has to reckon with. They are influenced by different uncertainty contributions. The quality parameter displacement error is used to check the ability of the DIC system to determine absolute displacements within the measurement volume and to confirm the traceability of this measurement to the SI system.
Reverification of DIC systems serves to ensure long-term compliance with specified limits for the quality parameters. By comparing the results of successive reverification measurements of the quality parameters used for the acceptance test, it is possible to analyze trends with respect to changes in DIC system characteristics.
Piezoresistive accelerometers use a strain-sensing element, generally made of semiconductor material, e.g., silicon to convert the mechanical motion into an electrical signal. This element is usually designed in form of a cantilever beam loaded with a mass. Acceleration causes bending of the beam, which produces a change of electrical resistance proportional to the applied acceleration.
Main advantages of piezoresistive accelerometers in comparison to other types, e.g., piezoelectric and capacitive, is their robust and highly dynamic behavior, which qualifies them for application in high impact shock applications. Mechanical damping is typically implemented with silicon oil in a way that the output signal is undistorted over a wide frequency range. These characteristics principally qualify them for the application in drop tests carried out at BAM, for which they are calibrated over the frequency range from 1 to 4 kHz. However, using silicon oil for damping, has the drawback of temperature dependent change of its viscosity, leading to temperature dependent deviation of the accelerometer’s sensitivity.
This study presents experimental results of the temperature behavior of a piezoresistive accelerometer with a dynamic range up to ±5000 g.
This type of accelerometer is applied for drop tests which are partially performed at temperatures of -40 or +100 °C.
Fibre Optic Sensing
(2013)
Embedded sensors
(2013)