Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (23)
- Vortrag (23)
- Zeitschriftenartikel (19)
- Beitrag zu einem Sammelband (9)
- Buchkapitel (7)
- Posterpräsentation (3)
- Handbuch (2)
- Forschungsbericht (2)
- Sonstiges (1)
Sprache
- Englisch (45)
- Deutsch (43)
- Mehrsprachig (1)
Schlagworte
- Sensorik (7)
- Messtechnik (6)
- Monitoring (5)
- Structural health monitoring (5)
- Application (2)
- Ausgleichsrechnung (2)
- Characterisation (2)
- Digital image correlation (DIC) (2)
- Digitale Bildkorrelation (DIC) (2)
- Drop test (2)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (5)
- 8.0 Abteilungsleitung und andere (2)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
- 8.4 Akustische und elektromagnetische Verfahren (2)
- 8.5 Röntgenbildgebung (2)
- 9 Komponentensicherheit (2)
- 4 Material und Umwelt (1)
- 4.2 Material-Mikrobiom Wechselwirkungen (1)
- 5 Werkstofftechnik (1)
- 5.1 Mikrostruktur Design und Degradation (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 8.3 Thermografische Verfahren (1)
- 9.3 Schweißtechnische Fertigungsverfahren (1)
- 9.4 Integrität von Schweißverbindungen (1)
- 9.5 Tribologie und Verschleißschutz (1)
- S Qualitätsinfrastruktur (1)
- S.0 Abteilungsleitung und andere (1)
- VP Vizepräsident (1)
- VP.1 eScience (1)
Eingeladener Vortrag
- nein (23)
Ergebnisunsicherheit im Prüfwesen- Eine Einführung in Systematik und praktische Vorgehensweisen
(2005)
Ergebnisunsicherheit im Prüfwesen - eine Einführung in Systematik und praktische Vorgehensweisen
(2005)
The thermo-oxidative stability of commercially available polymer optical fibers (POFs) and their components (cores and claddings) was investigated. All the bare POFs (core and cladding only) studied here were based on poly(methyl methacrylate) (PMMA) core. The fibers were exposed to 100 °C/low humidity for about 4200 h. Chemiluminescence (CL) technique was applied to investigate the thermo-oxidative stability and for measuring the transmission loss during exposure a prototype device called multiplexer was used. POFs exhibited variation in thermo-oxidative stability although they possessed identical core material PMMA. This was due to difference in the chemical compositions of claddings. Claddings were more susceptible to the thermo-oxidative degradation compared to cores. The thermo-oxidative degradation of both the cladding and the core was found in POFs as a result of climatic exposure. POFs showed an early drop-off followed by a slow decline of transmission. The early drop-off of transmission was attributed to physical changes like thermal expansion and the slow decline of transmission to chemical changes like oxidative degradation of POFs. A good linear relationship between optical transmission stability and thermo-oxidative stability of POFs was established from these studies.
Meßtechnik und Sensorik
(2007)
Entwicklung von Verfahren zur Beurteilung der Bildqualität von Radioskopie-Systemen aus der zerstörungsfreien Werkstoffprüfung nach einheitlichen, objektiven und quantitativen Kriterien, Betrachtung der physikalischen Grundlagen der Strahlungserzeugung, Strahlenreliefenstehung und -umwandlung sowie der damit verbundenen Einflussgrößen auf die Bildqualität. Herleitung und Definition von Bildqualitätsmerkmalen (radiographische Kriterien, Kenngrößen aus der Systemtheorie und allgemeine optische Abbildungseigenschaften), Beschreibung wichtiger Zusammenhänge zwischen einzelnen Bildqualitätsmerkmalen und bestimmten Geräteparametern.
VDE-VDI-Richtlinie 5570
(2003)