Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (23) (entfernen)
Schlagworte
- Monitoring (3)
- Drop test (2)
- Accelerometer (1)
- Application (1)
- Ausgleichsrechnung (1)
- Berlin Main Station (1)
- Condition monitoring (1)
- Data-fusion (1)
- Determination procedure (1)
- Differential displacements (1)
VDI/VDE-Guideline 5570 - The First Comprehensive Standard on Characterization and Testing of POF
(2002)
The stress vs. strain curve of materials is affected the rate of imposed straining. Among the methods for dynamic testing the technique known as 'split Hopkinson pressure bar' (SHPB) has evolved into the most widely used one to exert high-speed straining. The theory behind it comprises simple equations to compute stress and strain. The reliability of the strain analysis can be assessed by digital image correlation (DIC). The present results indicate that the visually observed strain is smaller than predicted by theory.
Standardization in fibre-optic sensing for structural safety - activities in the ISHMII and IEC
(2015)
Fiber-optic sensors are increasingly established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations to enhance the operational performance of aged structures or to monitor the structural behavior of safety-relevant structures or their components. However, there are some barriers in use due to a lack of extensive standardization of fiber-optic sensors. This leads very often to restraints in the users community. The paper shows the status in international standardization of fiber-optic sensors as well as current activities in leading institutions such as IEC and ISHMII and others with the purpose of providing relevant standards for a broader use of selected fiber-optic sensor technologies.
The Split Hopkinson Pressure Bar (SHPB) is a method for material characterization which works at strain rates from 102 - 104 1/s. This method can be used for example in the field of military engineering, in the field of deformation technology, automobile indurstry, aerospace industry or in other industrial fields. Controlled tests with the SHPB device enable Information about the dynamic material deformaion behaviour in the named strain rate area. The setup of the SHPB is not standarized and the measurement principle is dependent on simplifications. Due to this amongst others the problem with the dispersion of the measurement signal occurs. Furthermore it is possible that measurement uncertainties appear caused by the misalignment of the SHPB setup. In this work the influence of the alignment and a dispersion correction by pulse shaping is presented. On the one side for the alignment calibration tests are done. And on the other side for the dispersion influence correction with pulse shaping tests are done with TiA16V4. This material was choosen due to the fact that it can be compared with existing literature data.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Berlin Main Station is the largest multi-level station in Europe. Its daily passenger number amounts to over 300.000. Structures built for such a large number of people require a high-level safety standard. The station was built on the inner city site of the historic Lehrter Bahnhof. The conditions for building and start of operation were challenging by several reasons. The typical sandy ground with a high level of groundwater makes the permanent static stability of such a complex structure difficult. Several completed, ongoing, and planned construction activities in the immediate vicinity of the station influence the ground settlement of the whole area. On basis of the structural design an impact prediction was calculated, which expected certain vertical displacements particularly between the single columns of the outer concrete bridges of the building. These columns support the glass roof construction, which only allows a defined limit of displacement. In order to avoid damage, a concept for monitoring and adjusting potentially occurring displacements was developed for installation at the outer bridges of the station.