Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (25)
- Vortrag (7)
- Posterpräsentation (5)
Schlagworte
- Fluorescence (9)
- Signal amplification (6)
- Hybrid materials (5)
- Mesoporous materials (5)
- Multiplexing (4)
- Explosives detection (3)
- Mercury (3)
- Test strip analysis (3)
- Bead-based assay (2)
- DNA (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (7)
Gated hybrid delivery systems: En route to sensory materials with inherent signal amplification
(2013)
Hybrid nanoparticles with a large specific surface area are a particularly exciting vehicle for delivery applications. Such highly porous or container-like structures, usually prepared from silica and frequently from gold, can incorporate a large number of chemical substances such as drug and/or indicator molecules. When equipped with a chemically or physically addressable gating function at the openings of the voids, the release of the cargo can be controlled at will. Because many more molecules can be stored as cargo in the pores of the support than there are functional groups as anchoring sites for the gating entities attached to the outer surface (for efficient pore capping), the systems possess inherent features of (signal) amplification. The present article will introduce various design strategies for different types of physical (light, temperature, magnetism) and chemical (pH, metal ions, anion, small organic molecules, enzymes) stimuli in connection with drug and indicator release. We will highlight exciting aspects of combining both features in theranostic applications and will stress which requirements still have to be met by many of the systems to be readily applicable in a sensory context.
Set them free: Brightly fluorescent indicators that are loaded into mesoporous silica nanoparticle carriers, capped with bulky antibodies, are released into the lateral flow of a test strip upon analyte arrival. Integration of the system into a rapid, simple flow test with fluorescence readout is applied for the selective and sensitive determination of the presence of triacetone triperoxide (TATP) as a prototype small-molecule analyte (see figure).
In this work, the optimization of the immunochemical response of antibody-gated indicator delivery (gAID) systems prepared with mesoporous silica nanoparticles has been studied along various lines of system tailoring, targeting the peroxide-type explosive TATP as an exemplary analyte. The mechanism of detection of these gAID systems relies on a displacement of an antibody “cap” bound to hapten derivatives anchored to the surface of a porous hybrid material, allowing the indicator cargo stored in the mesopores to escape and massively amplify the analyte-related signal. Since our aim was to obtain gAID systems with the best possible response in terms of sensitivity, selectivity, and assay time, sera obtained from different immunization boosts were screened, the influence of auxiliary reagents was assessed, structural hapten modification (hapten heterology) was investigated, and various indicator dyes and host materials were tested. Considering that highly selective and sensitive immunological responses are best obtained with high-affinity antibodies which, however, could possess rather slow dissociation constants, leading to slow responses, the main challenge was to optimize the immunochemical recognition system for a rapid response while maintaining a high sensitivity and selectivity. The best performance was observed by grafting a slightly mismatching (heterologous) hapten to the surface of the nanoparticles in combination with high-affinity antibodies as “caps”, yielding for the first time gAID nanomaterials for which the response time could be improved from hours to <5 min. The materials showed favorable detection limits in the lower ppb range and discriminated TATP well against H2O2 and other explosives. Further optimization led to straightforward integration of the materials into a lateral flow assay without further treatment or conditioning of the test strips while still guaranteeing remarkably fast overall assay times.
The roughness as a property of core–shell (CS) microparticles plays a key role in their functionality. Quantitative evaluation of the roughness of CS microparticles is, however, a challenging task with approaches using electron microscopy images being scarce and showing pronounced differences in terms of methodology and results. This work presents a generalized method for the reliable roughness determination of nonplanar specimens such as CS particles from electron microscopic images, the method being robust and reproducible with a high accuracy. It involves a self-written software package (Python) that analyzes the recorded images, extracts corresponding data, and calculates the roughness based on the deviation of the identified contour. Images of single particles are taken by a dual mode scanning electron microscopy (SEM) setup which permits imaging of the same field-of-view of the sample with high resolution and surface sensitive in SE InLens mode as well as in transmission mode (TSEM). Herein, a new type of polystyrene core–iron oxide shell–silica shell particles is developed to serve as a set of lower micrometer-sized study objects with different surface roughness; the analysis of their images by the semiautomatic workflow is demonstrating that the particles’ profile roughness can be quantitatively obtained.
Die Kombination aus elektrogenerierter Chemilumineszenz (ECL) und Aptamer-gesteuerter Indikatorfreisetzung (gAID) aus magnetischen mesoporösen Silica-Nanopartikeln, die in mit Poly(ethylenglycol) und N-(3-Triethoxysilylpropyl) diethanolamin funktionalisiertes Glasfaserpapier eingebettet sind, ermöglichte die Entwicklung eines Schnelltests, mit dem sich Penicillin direkt in verdünnter Milch bis auf 50 +/- 9 ppt in <5 min nachweisen lässt. Die kovalente Bindung der Aptamer-Kappe an das Siliciumdioxid-Gerüst ermöglichte den Verschluss der Poren durch nicht-kovalente elektrostatische Wechselwirkungen mit Oberflächen-Aminogruppen. Die Bindung von Penicillin führte zu einer Faltung des Aptamers, wodurch der zuvor in das Material geladene ECL-Reporter Ru(bpy)32+ freigesetzt wurde und nach lateralem Fluss von einer Smartphone-Kamera nach elektrochemischer Anregung mit einer in einen 3D-gedruckten Halter eingesetzten Siebdruckelektrode detektiert wird. Der Ansatz ist einfach, generisch und bietet Vorteile hinsichtlich Empfindlichkeit, Messunsicherheit und Robustheit gegenüber konventioneller Fluoreszenz- oder elektrochemischer Detektion, insbesondere für Point-of-Need-Analysen anspruchsvoller Matrices und Analyten im Ultraspurenbereich.
Type-I pyrethroids are frequently used for disinfection purposes on airplanes from and to tropical areas. The WHO (Word Health Organization) defines “disinfection” as the procedure whereby health measures are taken to control or kill the insect vectors of human diseases including dengue, yellow fever and malaria.1 Due to this, a new effective and rapid method for pyrethroids analysis directly in the plane is needed.
To detect type-I pyrethroids, gated materials are constructed for the purpose of finely tuning the movement of a cargo from voids of a mesoporous inorganic support to a solution, in response to a predefined stimulus.2 Antibodies are bound to specific functional groups grafted on the support’s surface with the two-fold aim of closing the mesopores and working as biological receptors for the target compounds.2 A specific opening mechanism, activated selectively in presence of pyrethroids as analytes, is able to control the release of an indicator dye previously loaded inside the inorganic support. As only few molecules of pyrethroids are necessary to open a pore and release a large amount of dyes, the system shows an intrinsic signal amplification quantified as a fluorescence emission intensity.3
Different mesoporous silica supports (from nano- and microparticles to platelets and short fibers) were synthetized, characterized and functionalized following different capping strategies. In this contribution, we will compare the temporal response behaviour of the optimized gated materials to verify if the respective delivery systems are properly closed and how fast they can be opened in presence of the analytes. Our results indicate that the trends of the kinetics observed in solution show a better control of the closing/opening mechanism when the epitope region of the antibody (around 10 nm) properly fits the pore size of the carriers.
Because the incorporation of an antibody-gated dye-delivery system with a conventional test-strip-based lateral-flow assay allows for the detection of analytes down to the ppb level in an easy-to-operate manner and an overall assay time of 2–5 min, which is fast for a biochemical test,3 we carried out first model studies for a lateral flow test assay on membranes, using a smartphone setup for read-out.
The aim of this study is to determine the efficiency of loading and release of several zwitterionic, neutral, anionic and cationic dyes into/from mesoporous nanoparticles to find the optimum loading and release conditions for their application in detection protocols. The loading is carried out for MCM-41 type silica supports suspended in phosphate-buffered saline (PBS) buffer (pH 7.4) or in acetonitrile, involving the dyes (rhodamine B chloride, rhodamine 101 chloride, rhodamine 101 perchlorate, rhodamine 101 inner salt, meso-(4-hydroxyphenyl)-boron–dipyrromethene (BODIPY), sulforhodamine B sodium salt and fluorescein 27). As a general trend, rhodamine-based dyes are loaded with higher efficiency, when compared with BODIPY and fluorescein dyes. Between the rhodamine-based dyes, their charge and the solvent in which the loading process is carried out play important roles for the amount of cargo that can be loaded into the materials. The delivery experiments carried out in PBS buffer at pH 7.4 reveal for all the materials that anionic dyes are more efficiently released compared to their neutral or cationic counterparts. The overall best performance is achieved with the negatively charged sulforhodamine B dye in acetonitrile. This material also shows a high delivery degree in PBS buffer.
The combination of electrogenerated chemiluminescence (ECL) and aptamer-gated indicator delivering (gAID) magnetic mesoporous silica nanoparticles embedded into glass fibre paper functionalised with poly(ethyleneglycol) and N-(3-triethoxysilylpropyl)diethanolamine allowed the development of a rapid test that detects penicillin directly in diluted milk down to 50 ± 9 ppt in <5 min. Covalent attachment of the aptamer ‘cap’ to the silica scaffold enabled pore closure through non-covalent electrostatic interactions with surface amino groups, while binding of penicillin led to a folding-up of the aptamer thus releasing the ECL reporter Ru(bpy)32+ previously loaded into the material and letting it be detected after lateral flow by a smartphone camera upon electrochemical excitation with a screen printed electrode inserted into a 3D-printed holder. The approach is simple, generic and presents advantages with respect to sensitivity, measurement uncertainty and robustness compared with conventional fluorescence or electrochemical detection, especially for point-of-need analyses of challenging matrices and analytes at ultra-trace levels.
Rapid testing methods for the use directly at a point-of-need are expected to unfold their true potential especially when offering adequate capabilities for the simultaneous measurement of multiple analytes of interest. However, the implementation of multiplexing features while retaining simplicity, performance and portability is one of the prominent challenges in the field. Keeping in mind these challenges, we decided to combine the use of stimuli-responsive materials for small-molecule sensing relying on chemical signal amplification and their incorporation on paper strips for lateral-flow assays in a straightforward manner. Considering the modularity, high sensitivity and selectivity of antibody-gated indicator delivery systems, a multiplexed assay for three small-molecule explosives TATP, TNT and PETN was developed, allowing to detect the analytes simultaneously with a single test strip at lower ppb concentrations in liquid phase in <5 min, using a fluorescence reader or a smartphone for readout.
Because of the versatility of the hybrid material and the modularity of the assay architecture, it is obvious that this generic approach should be easily transferable to food or environmental analysis, point-of-care diagnostics and other areas of application in which the rapid screening for multiple parameters from liquid samples without clean-up in a dedicated laboratory is in demand.
The use of macromolecules and materials immobilized in the detection zone of test strips for indicator capture and focusing in label-free lateral flow assays (LFAs) is described, with emphasis on its future use in low number multiplexing. Several materials such as polyelectrolytes, functionalized mesoporous silica micro- and nanoparticles, chemically modified cellulose or glass fibre (GF) membranes and molecularly imprinted polymer gels coated onto membranes were studied in model assays, before the most promising materials were combined with antibody-gated indicator delivering (gAID) sensor materials. Cellulose, nitrocellulose and GF membranes were used as supports and highly fluorescent dyes of different charge states as model indicators. Combination of the best performing capture materials with gAID systems made it possible to distinctly increase the sensitivity and reduce the measurement uncertainty in the LFA testing of pentaerythritol tetranitrate (PETN) in aqueous samples. In addition, dual-plexing of PETN and 2,4,6-trinitrotoluene (TNT) was realized on a single test strip containing two dedicated capture zones.
We report herein the design of a strip-based rapid test utilizing bioinspired hybrid nanomaterials for the in situ and at site detection of the drug scopolamine (SCP) using a smartphone for readout, allowing SCP identification in diluted saliva down to 40 nM in less than 15 min. For this purpose, we prepared a nanosensor based on mesoporous silica nanoparticles loaded with a fluorescent reporter (rhodamine B) and functionalized with bethanechol, a potent agonist of recombinant human muscarinic acetylcholine receptor M2 (M2-AChR). M2-AChR interaction with the anchored bethanechol derivative leads to capping of the pores. The sensing mechanism relies on binding of SCP to M2-AChR resulting in pore opening and delivery of the entrapped rhodamine B reporter. Moreover, the material was incorporated into strips for lateral-flow assays coupled to smartphone readout, giving fast response time, good selectivity, and exceptional sensitivity. In an attempt to a mobile analytical test system for law enforcement services, we have also developed a dualplex lateral flow assay for SCP and 3,4-methylenedioxypyrovalerone (MDPV) also known as the so-called “cannibal drug”.
Test strips that in combination with a portable fluorescence reader or digital camera can rapidly and selectively detect chemical warfare agents (CWAs) such as Tabun (GA), Sarin (GB), and Soman (GD) and their simulants in the gas phase have been developed. The strips contain spots of a hybrid indicator material consisting of a fluorescent BODIPY indicator covalently anchored into the channels of mesoporous SBA silica microparticles. The fluorescence quenching response allows the sensitive detection of CWAs in the μg m−3 range in a few seconds.
The design of comparatively simple and modularly configurable artificial systems able to communicate through the exchange of chemical messengers is, to the best of our knowledge, an unexplored field. As a proof-of-concept, we present here a family of nanoparticles that have been designed to communicate with one another in a hierarchical manner. The concept involves the use of capped mesoporous silica supports in which the messenger delivered by a first type of gated nanoparticle is used to open a second type of nanoparticle, which delivers another messenger that opens a third group of gated nanoobjects. We believe that the conceptual idea that nanodevices can be designed to communicate with one another may result in novel applications and will boost further advances towards cooperative systems with complex behavior as a result of the communication between simple abiotic individual components.
Mercury is a highly toxic, bioaccumulative heavy metal that can cause serious health problems even at low concentrations, thus presenting a major threat for the natural water resources. Its high toxicity entails low MCL values (e.g., 2 ppb),[1] requiring at best materials that cannot only selectively detect Hg2+ at trace levels but also effectively remove it. Various such dual functional materials have been developed in the past.[2] However, most of these approaches have limitations with respect to sensitivity and selectivity, show slow responses or require complex instrumentation.
Here we report the development of mesoporous silica materials containing boron-dipyrromethene (BODIPY) probes in their pore systems that allow for the sensitive and selective detection of Hg2+ in water via fluorescence enhancement while at the same time efficiently scavenging the toxic heavy metal. For this purpose, we adopted an earlier strategy[3] and prepared a refined BODIPY probe which was directly adsorbed on the surface of SBA-15-type silica having been functionalized with different organic moieties. Of all the materials tested, SBA-15 expressing propyl chains responded best, allowing for an excellent discrimination against Ag+ and other metals as well as a high sensitivity for Hg2+ with a limit of detection of 1.5 ppb.
The performance of the hybrids with regard to sensing and scavenging was validated by ICP-OES measurements before and after exposure of the materials to Hg2+-containing solutions, allowing retentions of 0.07 g Hg2+ g solid-1. Control studies revealed that while the fluorescent probe is responsible for the very sensitive indication at low Hg2+ concentrations, the majority of the toxic metal ion is scavenged at the walls of the silica material. Current work is directed at the incorporation of these sensor particles into filtration systems for monitoring purposes.
Methods for the rapid and sensitive detection of target analytes are gaining importance in medical diagnostics and environmental monitoring, in the security, occupational health and safety as well as food sectors. Among all the methods employed for rapid tests, lateral flow assays (LFAs) are the most commonly used. However, some drawbacks are that most of these tests either indicate the analyte only indirectly, and in other cases the sensitivity is not high enough.
Keeping in mind these limitations, the use of stimuli-responsive materials for small-molecule sensing relying on chemical signal amplification and utilizing specific interactions between biomolecules such as antibodies and the corresponding analytes are particularly attractive. Such materials can also be incorporated on paper strips for lateral-flow assays in a straightforward manner. These sensing materials comprise mesoporous silica nanoparticles loaded with indicator molecules and containing certain hapten derivative molecules covalently grafted at the surface, which bind to the respective antibody and inhibit the release of a dye as reporter (Scheme 1). In presence of the designated analyte, a displacement of the antibody from the material is observed, allowing the release of dye. Because a large number of indicator molecules can be released when a single analyte molecule binds to an antibody cap, a strong signal amplification is observed.
Considering the modularity, high sensitivity and selectivity of these antibody-gated indicator delivery systems, the presentation discusses general aspects of system design as well as analytical performance and highlights the integration into a lateral-flow assay, showing as an example the determination of the explosives TATP, TNT and PETN with a fluorescence readout, in single-substance and multiplexing modes.
A droplet-based microfluidic sensor was developed for the detection of Hg2+ traces in water. The approach uses gated mesoporous nanoparticles loaded with a fluorescent BODIPY dye. The squaraine-based gating mechanism is highly selective for Hg2+ and the indicator release mechanism ensures sensitive detection. The microfluidic system is modular and was assembled from simple PTFE/PFA tubes, while detection was realized with standard optomechanic, optic, and electronic parts. The sensor shows a stable response without memory effects and allows the detection of Hg2+ in water down to 20 ppt.
The organophosphate nerve agents Tabun (GA), Sarin (GB) and Soman (GD) are among the most toxic chemical warfare agents (CWA) known, and exert their biological effects by irreversibly inhibiting acetylcholinesterase enzymes of the human nerve system. The use of these agents in the past century has killed millions of civilians around the world during World Wars I and II, and after that, approximately 40.000 tons of chemical ammunition were dumped into the Baltic Sea, containing ca. 13.000 tons of chemical warfare agents. Since their production, almost all the nations of the world have been strictly avoiding the development and use of CWA, participating in active destruction of CWA stockpiles, especially since the Chemical Weapon Convention (CWC) of 1993. However, CWA have been used in offensive ways against civilian population by terrorists, as for instance in the fatal Tokyo subway terror incident of 1995 or, most recently, against antigovernment demonstrators in Syria in 2013. Due to their higher toxicity and continuous use, it is therefore very important to develop simple and fast detection methods relying on new nerve agent sensing modalities for use in control and inspection.
A practically useful fluorescent probe must possess a rapid response and high sensitivity, and shall be implementable into easy-to-use devices for real time detection by untrained personnel. Taking into account this fact, in this work we have synthesized several mesoporous silica materials containing boron–dipyrromethene (BODIPY) moieties for the detection of nerve agents GA, GB and GD in the gas phase. Development of our system indicated that the most potent materials are able to respond to the presence of nerve agent simulants diethyl cyanophosphonate, diethyl chlorophosphate and diisopropyl fluorophosphate, which have to be used in a laboratory setting, yet also for the real nerve agents Sarin, Soman and Tabun, producing a strong quenching of the fluorescence. Furthermore, a portable device for the detection of GA, GB and GD in the gas phase has been prepared for in situ sensing and rapid screening applications, consisting of strips that are able to indicate the targets down to below 1 mgm-3 which is below the LD50 values.
The urgent necessity to carry out reliable and relevant analytical measurements directly at a point-of-need is one of the current drivers for the development of miniaturised analytical systems, quick tests and wearables. Despite their simplicity, this type of tests must guarantee analytical relevance and reliability like laboratory-based analysis, e.g., in terms of sensitivity, selectivity, immunity against false positives and false negatives as well as robustness and repeatability. Keeping in mind the high sensitivity offered by gated indicator-releasing micro- and nanoparticles due to their inherent features of signal amplification, we performed several optimisations to develop a potential biosensor platform for use in rapid tests. Conceptually, these gated materials are closely related to drug delivery systems, consisting of high porous materials usually closed with macromolecular “caps” and loaded with indicator molecules that are released in presence of a target analyte. However, the key difference between the two types of functional materials is that many drug delivery systems should deliver their cargo over a longer period, often many hours, whereas the gated materials prepared for sensing should show fast release kinetics, on the order of <5 min.
With the aim to optimise and adapt gated materials for sensing purposes, we prepared in this work several antibody-gated materials for small-molecule sensing. The materials consisted of porous silica particles containing indicator molecules in the pores and certain hapten molecules grafted to the particle surface close to the pore openings. The pores were then capped with antibodies binding to these haptens, thus inhibiting the escape of the indicators from inside of the pores. In presence of the corresponding analyte, the antibody is displaced from the surface of the material, allowing the escape of the indicators. This allows the detection of the analyte indirectly through an inherent signal amplification. In this work, the insecticide permethrin, a type-I pyrethroid, was selected as target model, because type-I pyrethroids play an important role in airplane disinfection. A first in-depth study of the various chemical tuning options of such antibody gated systems was performed. Different mesoporous silica supports, different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material’s pore openings, the better the closing/opening mechanism can be controlled. Because such materials can be used in various different formats from suspension assays[1] via microfluidic chips[2] to test strip-based lateral flow assays,[3] such materials present a powerful analytical particle platform for the sensitive analytics and diagnostics outside of a laboratory, realising sensitivities down to the µg kg–1 range in less analysis times of less than 5 min as we have recently demonstrated.[4]
The urgent necessity to carry out reliable and relevant analytical measurements directly at a point-of-need is one of the current drivers for the development of miniaturised analytical systems, quick tests and wearables. Despite their simplicity, this type of tests must guarantee analytical relevance and reliability like laboratory-based analysis, e.g., in terms of sensitivity, selectivity, immunity against false positives and false negatives as well as robustness and repeatability. Keeping in mind the high sensitivity offered by gated indicator-releasing micro- and nanoparticles due to their inherent features of signal amplification, we performed several optimisations to develop a potential biosensor platform for use in rapid tests. Conceptually, these gated materials are closely related to drug delivery systems, consisting of high porous materials usually closed with macromolecular “caps” and loaded with indicator molecules that are released in presence of a target analyte. However, the key difference between the two types of functional materials is that many drug delivery systems should deliver their cargo over a longer period, often many hours, whereas the gated materials prepared for sensing should show fast release kinetics, on the order of <5 min.
With the aim to optimise and adapt gated materials for sensing purposes, we prepared in this work several antibody-gated materials for small-molecule sensing. The materials consisted of porous silica particles containing indicator molecules in the pores and certain hapten molecules grafted to the particle surface close to the pore openings. The pores were then capped with antibodies binding to these haptens, thus inhibiting the escape of the indicators from inside of the pores. In presence of the corresponding analyte, the antibody is displaced from the surface of the material, allowing the escape of the indicators. This allows the detection of the analyte indirectly through an inherent signal amplification. In this work, the insecticide permethrin, a type-I pyrethroid, was selected as target model, because type-I pyrethroids play an important role in airplane disinfection. A first in-depth study of the various chemical tuning options of such antibody gated systems was performed. Different mesoporous silica supports, different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material’s pore openings, the better the closing/opening mechanism can be controlled. Because such materials can be used in various different formats from suspension assays[1] via microfluidic chips[2] to test strip-based lateral flow assays,[3] such materials present a powerful analytical particle platform for the sensitive analytics and diagnostics outside of a laboratory, realising sensitivities down to the µg kg–1 range in less analysis times of less than 5 min as we have recently demonstrated.[4]
The employment of type-I pyrethroids for airplane disinfection in recent years underlines the necessity to develop sensing schemes for the rapid detection of these pesticides directly at the point-of-use. Antibody-gated indicator-releasing materials were thus developed and implemented with test strips for lateral-flow assay-based analysis employing a smartphone for readout. Besides a proper matching of pore sizes and gating macromolecules, the functionalization of both the material's outer surface as well as the strips with PEG chains enhanced system performance. This simple assay allowed for the detection of permethrin as a target molecule at concentrations down to the lower ppb level in less than 5 minutes.
Rapid testing methods for the use directly at apointof need are expected to unfold their true potential especiallywhen offering adequate capabilities for the simultaneousmeasurement of multiple analytes of interest. Considering theunique modularity,high sensitivity,and selectivity of antibody-gated indicator delivery (gAID) systems,amultiplexed assayfor three small-molecule explosives (TATP, TNT,PETN) wasthus developed, allowing to detect the analytes simultaneouslywith asingle test strip at lower ppb concentrations in the liquidphase in < 5min using afluorescence reader or asmartphonefor readout. While the TNT and PETN systems were newlydeveloped here,all the three systems also tolerated harshermatrices than buffered aqueous model solutions.Besidesasingle-track strip,the outstanding modularity of the hybridbiosensor materials in combination with strip-patterningtechnologies allowed us to obtain amultichannel strip inastraightforwardmanner,offering comparable analyticalperformance while allowing to be tailored even more to theusersneed.
Vor dem Hintergrund der einzigartigen Modularität, hohen Empfindlichkeit und Selektivität von Antikörper‐gesteuerten Indikatorfreisetzungssystemen (gAID‐Systemen) wurde hier ein Multiplex‐Assay für drei organische Explosivstoffmoleküle (TATP, TNT, PETN) entwickelt, der es erlaubt, die Analyten gleichzeitig in flüssiger Phase mit einem einzelnen Teststreifen und einem Fluoreszenzlesegerät bzw. Smartphone als Detektor in Konzentrationen bis in den unteren ppb‐Bereich in <5 min nachzuweisen. Alle drei Systeme, darunter die hier neu entwickelten Systeme für TNT und PETN, tolerieren zudem nicht nur gepufferte wässrige Modelllösungen, sondern auch komplexere Matrices. Neben einem konventionellen Teststreifen mit einem Kanal erlaubte uns die Anwendung von Wachsdrucktechnologie das Herstellen von mehrkanaligen Streifen mit vergleichbarer analytischer Leistungsfähigkeit, was das enorme Potenzial der modular aufgebauten, hybriden Biosensormaterialien im Hinblick auf eine für den Endanwender maßgeschneiderte Vor‐Ort‐Analytik unterstreicht.
Antibody-gated indicator delivery (gAID) systems based on mesoporous silica nano- and microparticle scaffolds are a promising class of materials for the sensitive chemical detection of small-molecule analytes in simple test formats such as lateral flow assays (LFAs) or microfluidic chips. Their architecture is reminiscent of drug delivery systems, only that reporter molecules instead of drugs are stored in the voids of a porous host particle. In addition, the pores are closed with macromolecular “caps” through a tailored “gatekeeping” recognition chemistry so that the caps are opened when an analyte has reacted with a “gatekeeper”. The subsequent uncapping leads to a release of a large number of indicator molecules, endowing the system with signal amplification features. Particular benefits of such systems are their modularity and adaptability. With the example of the immunochemical detection of type-I pyrethroids by fluorescent dye-releasing gAID systems, the influence of several tuning modes on the optimisation of such hybrid sensory materials is introduced here. In particular, different mesoporous silica supports (from nano- and microparticles to platelets and short fibres), different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in the absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material's pore opening, the better the closing/opening mechanism can be controlled. Because such materials are well-suited for LFAs, performance assessment included a test-strip format besides conventional assays in suspension. In combination with dyes as indicators and smartphones for read-out, simple analytical tests for use by untrained personnel directly at a point-of-need such as an aeroplane cabin can be devised, allowing for sensitivities down to the μg kg−1 range in <5 min with case-required selectivities.
Functional core/shell particles are highly sought after in analytical chemistry, especially in methods suitable for single-particle analysis such as flow cytometry because they allow for facile multiplexed detection of several analytes in a single run. Aiming to develop a powerful bead platform of which the core particle can be doped in a straightforward manner while the shell offers the highest possible sensitivity when functionalized with (bio)chemical binders, polystyrene particles were coated with different kinds of mesoporous silica shells in a convergent growth approach. Mesoporous shells allow us to obtain distinctly higher surface areas in comparison with conventional nonporous shells. While assessing the potential of narrow- as well as wide-pore silicas such as Mobil composition of matter no. 41 (MCM-41) and Santa Barbara amorphous material no. 15 (SBA-15), especially the synthesis of the latter shells that are much more suitable for biomolecule anchoring was optimized by altering the pH and both, the amount and type of the mediator salt. Our studies showed that the best performing material resulted from a synthesis using neutral conditions and MgSO4 as an ionic mediator. The analytical potential of the particles was investigated in flow cytometric DNA assays after their respective functionalization for individual and multiplexed detection of short oligonucleotide strands. These experiments revealed that a two-step modification of the silica surface with amino silane and succinic anhydride prior to coupling of an amino-terminated capture DNA (c-DNA) strand is superior to coupling carboxylic acid-terminated c-DNA to aminated core/shell particles, yielding limits of detection (LOD) down to 5 pM for a hybridization assay, using labeled complementary single-stranded target DNA (t-DNA) 15mers. The potential of the use of the particles in multiplexed analysis was shown with the aid of dye-doped core particles carrying a respective SBA-15 shell. Characteristic genomic sequences of human papillomaviruses (HPV) were chosen as the t-DNA analytes here, since their high relevance as carcinogens and the high number of different pathogens is a relevant model case. The title particles showed a promising performance and allowed us to unequivocally detect the different high- and low-risk HPV types in a single experimental run.
Microbial contamination of fuels by fungi and bacteria presents risks of corrosion and fuel system fouling. In this work, a rapid test for the determination of microbial genomic DNA from aqueous fuel extracts is presented. It combines test strips coated with polystyrene core/mesoporous silica shell particles, to the surface of which modified fluorescent molecular beacons are covalently grafted, with a smartphone detection system. In the hairpin loop, the beacons incorporate a target sequence highly conserved in all bacteria, corresponding to a fragment of the 16S ribosomal RNA gene, which is also present to a significant extent in the 18S rRNA gene of fungi, allowing for broadband microbial detection. In the developed assay, the presence of genomic DNA extracts from bacteria and fungi down to ca. 20−50 μg L−1 induced a distinct fluorescence response. The optical read-out was adapted for on-site monitoring by combining a 3D-printed case with a conventional smartphone, taking advantage of the sensitivity of contemporary complementary metal oxide semiconductor (CMOS) detectors. Such an embedded assembly allowed to detect microbial genomic DNA in aqueous extracts down to ca. 0.2−0.7 mg L−1 and presents an important step toward the on-site uncovering of fuel contamination in a rapid and simple fashion.
A novel mesoporous silica material containing boron–dipyrromethene (BODIPY) moieties (I) is employed for the detection of nerve agent simulants (NASs) and the organophosphate nerve or chemical warfare agents (CWAs) Sarin (GB), Soman (GD), and Tabun (GA) in aqueous environments. The reactive BODIPY dye with an optimum positioned hydroxyl group undergoes acylation reactions with phosph(on)ate substrates, yielding a bicyclic ring. Due to aggregation of the dyes in water, the sensitivity of the free dye in solution is very low. Only after immobilization of the BODIPY moieties into the silica substrates is aggregation inhibited and a sensitive determination of the NASs diethyl cyanophosphonate (DCNP), diethyl chlorophosphate (DCP) and diisopropyl fluorophosphate (DFP) possible. The signaling mode is a strong quenching of the fluorescence, reaching LODs in the pM range. The best performing hybrid material was singled out from a library of hybrid silicas varying in morphology and surface functionalization. The response to actual CWAs such as GB, GD, and GA has also been tested, offering similar behavior as for the simulants. The proposed reaction mechanism has been verified by investigation of other model materials, containing for instance BODIPY moieties without an optimum hydroxyl group (III) or a BODIPY dye with an all-aliphatic counterpart (IV). The latter can only form a monocyclic reaction product, showing much less reactivity as I. Assays with other possible competitors have been additionally carried out, showing favorably low cross-reactivities. Finally, the determination of NASs in several natural waters has been demonstrated.
Invited for this month’s cover picture is the group of Dr. Knut Rurack at the Department of Analytical Chemistry; Reference Materials at the Bundesanstalt fuer Materialforschung und -pruefung (BAM) in Berlin (Germany). The cover picture shows how differences in color and fluorescence on a test strip can be easily read out with a mobile device. Two reference spots Frame the sensitive spot that indicates the presence of trace amounts of HgII below the threshold in a natural water sample. This dipstick contains a hybrid material that combines boron-dipyrromethene (BODIPY) probes sterically loaded into specifically tailored mesoporous silica particles, allowing for ultrasensitive HgII detection through enhanced fluorescence in a few seconds. The applicability in real water samples and fish extracts are also studied.
Commercial bead-based assays are commonly built upon polystyrene particles. The polymeric carrier can be encoded with organic dyes and has ideal material properties for cytometric applications such as low density and high refractive index. However, functional groups are conventionally integrated during polymerization and subsequent modification is limited to the reactivity of those groups. Additionally, polystyrene as the core material leads to many hydrophobic areas still being present on the beads’ surfaces even after functionalization, Rendering the particles prone to nonspecific adsorption during an application. The latter calls for several washing steps and the use of additives in (bio)analytical assays. In this contribution, we show how these limitations can be overcome by using monodisperse polystyrene (PS) core/silica (SiO2) shell particles (SiO2@PS). Two different hydrophobic BODIPY (boron−dipyrromethene) dyes were encapsulated inside a poly(vinylpyrrolidone) (PVP) -stabilized polystyrene core in different concentrations to create 5-plex arrays in two separate detection channels of a cytometer. A subsequent modification of the silica shell with an equimolar APTES/PEGS (aminopropyltriethoxysilane/polyethylene glycol silane) blend added multifunctional properties to the hybrid core/Shell microparticles in a single step: APTES provides amino groups for the attachment of a caffeine derivative (as a hapten) to create antigen-coupled microspheres; the PEG moiety effectively suppresses nonspecific binding of antibodies, endowing the surface with antifouling properties. The particles were applied in a competitive fluorescence immunoassay in suspension, and a highly selective wash-free assay for the detection of caffeine in beverages was developed as a proof of concept.
The synthesis, characterization, and application of mesoporous materials containing boron–dipyrromethene (BODIPY) moieties that allow the sensitive and selective detection of HgII in aqueous environments by fluorescence enhancement is reported. For this purpose, BODIPY dye I containing a thia‐aza crown ether receptor as the fluorescent probe for the detection of HgII in aqueous environments is encapsulated into mesoporous materials to avoid self‐quenching or aggregation in water. Determination of HgII is accomplished within a few seconds with high selectivity and sensitivity, reaching a limit of detection of 12 ppt. The determination of trace amounts of HgII in natural waters and in fish extracts is demonstrated by using our sensing material. The incorporation of the material into several μ‐PAD strips yields a portable, cheap, quick, and easy‐to‐handle tool for trace HgII analysis in water.
Methods for the rapid and sensitive detection of target analytes are gaining importance in medical diagnostics and environmental monitoring, in the security, occupational health and safety as well as food sectors. Among all of the methods employed for rapid tests, lateral flow assays (LFAs) are the most commonly used, and hundreds of test kits based on this technique are available on the market. A major drawback is that most of these capture agents either indicate the analyte only indirectly, and in most cases a second binding agent able to bind directly or indirectly to the analytes is necessary (e.g., a secondary labeled antibody). Furthermore, in certain cases in which the (ultra)trace detection of an analyte is required, the traditional approach of a certain number of probe molecules being conjugated to a particular support is not sufficient. Therefore, novel concepts implementing steps of effective signal amplification are urgently required.
Keeping in mind these limitations, we thought that the sensitivity of these systems should be improvable through employment of gated reporter molecule-releasing hybrid nanoparticle materials on novel lateral flow devices. On one hand, the gated sensor material can produce a massive signal amplification, by releasing many reporter molecules only after chemical recognition of a few analyte molecules has taken place in an independent and separate step at the pore openings. On the other hand, the employment of tailored capture materials for the selective interaction with the released reporter molecules in a second arbitrary zone on the strip allows to concentrate or focus the latter for more efficient detection or to create selective multi-spot detection zones, which renders the simultaneous detection of several reporter molecules at the same time in multiplexed detection of various analytes possible.
For that purpose, we have prepared several stimuli-responsive materials for small-molecule sensing based on specific interactions between biomolecules such as antibodies with the corresponding analytes for the detection of certain explosives. In order to prepare these bio-capped materials, we have selected silica mesoporous nanoparticles (MSNs) as inorganic support due to their unique properties such as defined void structure, high inner surface area and flexible functionalization chemistry. These MSNs are loaded with a brightly fluorescent indicator dye, and the external surface is subsequently functionalized with suitable molecules able to interact with antibodies, efficiently inhibiting dye release. The opening protocol and delivery of the entrapped dye is reminiscent of a displacement reaction involving the presence of the target analyte, producing a displacement of the biomolecule and allowing the detection of the target analyte.
The presentation discusses general aspects of system design as well as analytical performance and highlights the integration into a lateral-flow assay, showing as an example the determination of the explosives TATP, TNT and PETN with fluorescence readout, in single-substance and multiplexing modes.