Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody.
The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters.
Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LCMS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively.
Caffeine (1,3,7-trimethylxanthine) and coprostanol (5β-cholestan-3β-ol) were detected in samples of Berlin's surface water. Their concentrations correlated with the contamination status of the samples, suggesting their usefulness as markers of human activity. Remarkably, caffeine concentrations were always well above the limit of quantitation of 0.025 µg/L.
In order to screen surface water samples in larger series, the development of two novel methods was required: a monoclonal antibody-based immunoassay for caffeine and a dispersive liquid-liquid microextraction (DLLME) method, followed by liquid chromatography tandem mass spectrometry (LC-MS/MS) for coprostanol.
The caffeine immunoassay developed shows the best analytical limit of detection (LOD) obtained so far for caffeine (0.001 µg/L), allows high-throughput analysis, and does not require sample pre-treatment. The assay was also successfully employed to measure caffeine in beverages, shampoos, caffeine tab-lets, and human saliva.
Antibodies to coprostanol are not commercially available. A new strategy to generate anti-coprostanol antibodies was elaborated using an analogous com-pound as hapten – isolithocholic acid (ILA) – and immunizing a group of mice. A polyclonal anti-ILA serum was produced, which binds coprostanol but the low affinity did not permit setting up an immunoassay to measure environmental concentrations of the analyte (in the range of ng/L).
Specific anti-ILA immunoglobulin G were also found in the faeces of the immunized mice.
Coprostanol was quantified in the water samples using a newly developed LC-MS/MS method using atmospheric pressure chemical ionisation (APCI). Concentrations above 0.1 µg/L were determined after sample preconcentration using DLLME. This extraction method also proved to be successful for enrichment of coprostanol-related compounds such as cholesterol, cholestanol, cholestanone, ergosterol, and stigmasterol.
A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling.
The title compound [systematic name: 6-(1,3-dimethyl-2,6-dioxo-2,3,6,7-tetrahydro-1H-purin-7-yl)hexanoic acid monohydrate, CAS 61444-23-3], C13H18N4O4·H2O, was synthesized and crystallized from ethyl acetate. Hydrogen bonds between xanthine and water molecules contribute to the formation of layers parallel to (10).
The chemistry of caffeine
(2012)
Caffeine is a useful indicator to quickly assess liver function. High-throughput tests are needed for single-point caffeine measurements, with low cross-reactivity toward its major metabolite, paraxanthine. A newly developed ELISA was compared with an LC-MS/MS reference method, using 60 saliva samples from 10 individuals, before and after caffeine intake. Bland-Altman plot, Student t-test and F-test were used to compare the two methods. Proteins were precipitated using organic solvent and the caffeine recoveries compared with those obtained using sample microfiltration. The antibody, with a low cross-reactivity toward paraxanthine (0.08%), allows quantification of caffeine in saliva samples from 2.5 µg/L to 125 µg/L with high precision and the ELISA shows comparable results to those obtained by LC-MS/MS. A one-step protein precipitation using an organic solvent provides comparable results to a more costly and time-consuming microfiltration pre-treatment of samples. The new ELISA is a fit-for-purpose method to accurately and precisely determine caffeine in saliva samples.
The synthesis of a novel PS conjugated with bovine and human serum albumin (BSA and HSA) and a monoclonal antibody anti-CD104 is reported, as well as their biological potential against the human bladder cancer cell line UM-UC-3. No photodynamic effect was detected when the non-conjugated porphyrin was used. Yet, when it was coupled covalently with the mAb anti-CD104, BSA and HSA, the resulting photosensitizer conjugates demonstrated high efficacy in destroying the cancer cells, the mAb anti-CD104 efficacy overruling the albumins.