Electrochemical methods offer great promise in meeting the demand for user-friendly on-site devices for Monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme-linked immunosorbent assays, with photometric detection of 3,3’,5,5’-tetramethylbenzidine (TMB),form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detectionstep, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphonebased, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis forsensing of further analytes.
Partikelbasierte Multianalyt- Fluoreszenzimmunoassays für die Unweltanalytik und Biotechnologie
(2021)
Zur Beurteilung der Wasserqualität können Markersubstanzen, wie Carbamazepin, Diclofenac, Koffein und Gallensäuren, verwendet werden. Erhöhte Konzentrationen dieser anthropogenen Marker weisen auf Einleitstellen von Abwasser hin und zeigen somit an, wo Gewässer verschmutzt werden. Diese Arbeit beschreibt deshalb die Etablierung, Optimierung und Validierung eines partikelbasierten Suspensionsarray Fluoreszenzimmunoassays (SAFIA), mit dem diese Substanzen gleichzeitig und parallel in vielen Proben quantitativ bestimmt werden können. Für SAFIA wurde das Format des kompetitiven indirekten Immunoassays gewählt. Als Plattform wurden fluoreszenzintensitätscodierte Polystyrol-Kern/Siliziumdioxid-Schale-Partikel, auf deren Oberfläche Haptene als kompetitive Bindungsstellen für Antikörper immobilisiert wurden, verwendet. Hier zeigte sich, dass eine selektive Erkennung der Haptenstruktur auf der Oberfläche der Partikel durch die Antikörper nur gegeben war, wenn die Partikel zusätzlich mit Polyethylenglykolgruppen funktionalisiert wurden. Zum Auslesen des Fluoreszenzsignals wurde ein Durchflusszytometer verwendet. Kompatibilität mit der Durchführung in Mikrotiterplatten wurde erreicht, indem eine Stopp-lösung für den SAFIA, basierend auf Formaldehyd, entwickelt wurde. Nach der Optimierung der Assayparameter können die oben genannten vier Analyten gleichzeitig in einer Probe mindestens bis zu einer Konzentration von 0.3 μg L-1 nachgewiesen werden. Der Assay kann ohne Wasch-schritte ausgeführt werden und ist somit einfacher als konventionelle Immunoassays, wie z. B. ELISA. Der SAFIA wurde hinsichtlich Interferenzen und Selektivität untersucht. Dabei zeigte sich, dass Matrixbestandteile, die in wässrigen Umweltproben vorkommen, keinen bzw. nur einen ge-ringen Einfluss auf den SAFIA hatten. Im simulierten Umweltscreening eines Flusses und mithilfe der Analyse von Abwasserproben wurde SAFIA validiert; hier zeigte SAFIA eine mit ELISA vergleich-bare Genauigkeit, bei gleichzeitiger Senkung der Analysenzeit und -kosten. Die gleichzeitige Detektion mehrerer anthropogener Marker erlaubte zudem Rückschlüsse auf die Art von Verschmutzungsquellen, im Gegensatz zu ELISA, mit dem nur ein Analyt bestimmt werden kann. Da hochaffine Antikörper für Immunoassays essenziell sind, wurde ein SAFIA zum Screening antikörperproduzierenden Zellen (Hybridomzellen) entwickelt und eingesetzt. Durch die Implementierung eines Sandwichimmunoassays zur IgG Bestimmung und durch Verwendung von homo- und heterologen Haptenstrukturen konnten aus einem Pool von Hybridomzellen diejenigen ausgewählt werden, deren sekretierter Antikörper die geringsten Nachweisgrenzen im Immunoassay erlauben. Damit konnte das Anwendungsspektrum des SAFIA maßgeblich vergrößert werden. Er vereinfacht als biotechnologisches Werkzeug stark sowohl die Produktion von monoklonalen Antikörpern als auch die Analyse von Umweltproben.
A bead suspension array for measuring emerging pollutants and anthropogenic markers in wastewater
(2016)
Background: The assessment of water quality demands for high-throughput and multi-target compatible analytical methods. On the one hand, the influence of sewage on natural surface waters must be routinely monitored - according to the European Water Framework Directive. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, are often applied in this area owing to their cost-efficiency and high-throughput capability. However, it is only possible to measure a single analyte in one measurement. In contrast, array technology is capable for measuring multiple substances in parallel. Here we present a four-plex bead-based flow cytometric assay for measuring three drugs (carbamazepine, an anti-epileptic drug, diclofenac, an antiphlogistic and caffeine, a psychoactive substance) and the bile acid isolithocholic acid, which is proposed to be used as a fecal marker. The drugs can be detected from 1 to 4 µg/L and the bile acid can be detected up to 72 µg/L in wastewater, requiring a highly sensitive detection method.
Methods: We use core-shell particles as the spherical platform, consisting of a polystyrene core and a silica shell. Such beads can easily be encoded with an organic fluorophore in the core and functionalized with amino groups on the silica shell surface for creating binding sites for antibodies: Therefore, the marker substances are bound to the amino groups via NHS chemistry. The hybrid particles were synthesized in house. Polystyrene was chosen as core material because of its low density and high refractive index, both important requirements for the use in suspension arrays. Easy surface modifications using silane chemistry are accessible on the silica shell. For the determination of the pollutants, the beads are incubated with a mixture of the analyte-specific antibodies. The antibodies undergo a competitive reaction to bind the immobilized molecules on the surface of the beads or the free analyte in the solution, respectively. Bound antibodies can then be visualized via fluorophore-labelled secondary antibodies. For read-out a flow cytometer is used to virtually separate the different dye encoded beads and to measure the resulting Signal intensity of the immunoassay. A four-parametric function was used as calibration curve.
Results: In order to obtain highly selective binding of the antibodies, we investigated different types of silica shell surface modifications to overcome unspecific binding, finding that a PEG-modified surface is suitable to support our immunoassay format. Multiplexed small molecule detection can therefore be realized in a simple mix and read procedure without washing steps.
Conclusion: We presented a multiplexing suspension array for the detection of four marker substances in wastewater samples, based on an indirect immunoassay format with polystyrene core-silica shell microbeads. The resulting multiplexing assay is appropriate to detect the marker substances in the low µg/L range. Therefore, wastewater samples can be measured without further preconcentration.
A bead suspension array for measuring emerging pollutants and anthropogenic markers in wastewater.
(2016)
The assessment of water quality demands for high-throughput and multi-target compatible analytical methods. On the one hand, the influence of sewage on natural surface waters must be routinely monitored - according to the European Water Framework Directive. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, are often applied in this area owing to their cost-efficiency and high-throughput capability. However, it is only possible to measure a single analyte in one measurement.
In contrast, array technology is capable for measuring multiple substances in parallel. Here we present a four-plex bead-based flow cytometric assay for measuring three drugs (carbamazepine, an anti-epileptic drug, diclofenac, an antiphlogistic and caffeine, a psychoactive substance) and the bile acid isolithocholic acid, which is proposed to be used as a fecal marker.
In this suspension array core-shell particles, consisting of a polystyrene core and a silica shell are used. They can be easily encoded with a fluorophore which is introduced to the core and functionalized with amino groups on the surface for creating binding sites for antibodies: Therefore, the marker substances are bound to the amino groups via NHS chemistry.
For the determination of the pollutants, the beads are incubated with a mixture of the analyte-specific antibodies. The antibodies undergo a competitive reaction to bind the immobilised molecules on the surface of the beads or the free analyte in the solution, respectively. Bound antibodies can then be visualized via fluorophore-labelled secondary antibodies. For read-out a flow cytometer is used to virtually separate the different encoded beads and to measure the resulting signal intensity of the immunoassay. In order to obtain highly selective binding of the antibodies, we investigated different types of surface modifications to overcome unspecific binding, finding that a PEG-based surface is suitable to support our immunoassay format. The resulting multiplexing assay is appropriate to detect the marker substances in the low µg/L range.
The demands for the assessment of water quality are increasing steadily, making it necessary to routinely monitor multiple contaminants in water samples. For this application a hapten microarray was developed. In order to reach the required low detection limits a design of experiments (DoE) approach was used to optimize the assay performance. Here we show that a Box-Behnken design plan is an adequate choice for the straightforward exploration of hapten microarray assay parameters. For both read-out systems studied (fluorophore-labelled detection antibodies or enzymatic signal development followed by reflectometric scan, respectively), it was possible to significantly extend the measurement ranges. Furthermore, it could be shown that multivariate data analysis, here partial least squares regression (PLS), can improve the prediction accuracy of 'unknown' samples when used as calibration model, compared to classical, univariate data evaluation methods.
Pharmaceuticals, certain food ingredients, and mammalian endogenous metabolic products in wastewater are mostly of human origin. They are anthropogenic markers.
Proper knowledge of their levels in wastewater helps to track sources of pollutants in natural waters and allows for calculation of removal efficiencies in wastewater Treatment plants. Here, we describe the development and application of an indirect competitive, multiplexing suspension Array fluorescence immunoassay (SAFIA) for the detection of carbamazepine (CBZ), diclofenac (DCF), caffeine (CAF), and isolithocholic acid (ILA) in wastewater, covering those classes of anthropogenic markers. The assay consists of haptens covalently conjugated to fluorescence-encoded polystyrene core/silica shell microparticles to create a site for competitive binding of the antibodies (Abs). Bound Abs are then stained with fluorophore-labeled Abs. Encoding and signaling fluorescence of the particles are determined by an automated flow cytometer.
For compatibility of the immunoassay with the 96-well microtiter plate format, a stop reagent, containing formaldehyde, is used. This enables a wash-free procedure while decreasing time-to-result. Detection limits of 140 ± 40 ng/L for CBZ, 180 ± 110 ng/L for CAF, 4 ± 3 ng/L for DCF, and 310 ± 70 ng/L for ILA are achieved, which meet the sensitivity criteria of wastewater analysis. We demonstrate the applicability of SAFIA to real wastewater samples from three different wastewater Treatment plants, finding the results in good agreement with LC-MS/MS. Moreover, the accuracy in general exceeded that from classical ELISAs. We therefore propose SAFIA as a quick and reliable approach for wastewater analysis meeting the requirements for process analytical technology.
The lab-on-valve (LOV) is a mesofluidic platform that has been recently exploited for
the automation and miniaturization of bioanalytical assays, resorting namely to
molecular recognition schemes based on immunosensing. Due to its high versatility
for reagent accommodation, it is possible to establish immunoassays under several
formats (eg. direct competitive ELISA, sandwich ELISA or even label-free immunoaffinity
chromatography). For instance, the LOV has been used as a manifold for
UV-vis micro-Bead Injection Spectroscopy (μ-BIS), a technique that involves the
quantification of the target analyte by direct measurement on the surface of a solid
phase capable of retaining the target analyte by molecular recognition.
The μ-BIS-LOV strategy affords several analytical advantages, namely short time-toresult
intervals (3 to 15 min), low sample volume (1-20 μL), automated solution handling
and washing steps, downscaling of reagents’ consumption, low-cost analysis
and little generation of waste. Additionally, the solid support is renewed before each
determination, minimizing surface fouling, cross-contamination issues and functional
group deactivation. No sample clean-up steps are required because interferences
are separated from the target analyte upon quantification mediated by a molecular
recognition element attached to the micro-bead column. The portability of the LOV
device makes it compatible with point-of-care testing.
To our knowledge, this technique has been mainly employed for the evaluation and
optimization of bioaffinity processes, but its potential for clinical and environmental
analysis remains underexploited. Hence, in this communication, different immunosensing
strategies using the LOV platform will be addressed, namely the determination
of autoimmune IgG in human serum, and the assessment of drug (carbamazepine)
levels in wastewater samples.
Pollutants of low molecular weight, such as drug residues, are in the focus of water quality assessment: some of them, like carbamazepine are only partially degraded in wastewater treatment plants. Thus, these pollutants can serve as marker substances for elimination efficiencies. Monitoring water quality demands for selective, high-throughput and multi-target analytical methods. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the specific recognition by high affinity of target molecules to antibodies (Abs). Batch-wise processing in microtiter plates allows for the necessary high-throughput, however only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex microbead-based flow cytometric assay, which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core/silica-shell particles. While, the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica shell creates a solid support for the immunoassay: The target analytes, three drugs, carbamazepine, diclofenac and caffeine and the fecal marker isolithocholic acid are coupled covalently to the surface via NHS chemistry to amino groups on the surface.
For determination of the pollutants, a mixture of specific Abs is incubated with the samples, to bind competitively on the “anchor” molecules on the surface of the beads or the analyte in solution. Bound antibodies are then visualized via fluorescent dye-labelled secondary Abs. Flow-cytometry allows for decoding of the beads and signal read-out, without washing the system. In order to decrease non-specific binding, we investigated different types of surface modifications, finding, that a PEG-based surface is suitable to support our immunoassay format. For maximum sensitivity, a design-of-experiment approach was chosen for optimization of the assay parameters. The resulting immunoassay is appropriate to quantify the pollutants in the low μg/L-range.
The assessment of water quality demands for multi-target compatible analytical methods. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, are often applied in this area, however, it is only possible to measure a single analyte in one measurement.
In contrast, array technology is capable for measuring multiple substances in parallel. Here we present a four-plex bead-based flow cytometric assay for measuring three drugs (carbamazepine, an antiepileptic drug, diclofenac, an antiphlogistic and caffeine, a psychoactive substance) and the bile acid isolithocholic acid, which is proposed to be used as a fecal marker.
In this suspension array core-shell particles, consisting of a polystyrene core and a silica shell, are used. They can be easily encoded with a fluorophore which is introduced to the core while the shell is functionalized with amino groups to which the analytes or their derivates are bound via NHS chemistry. They are the competitor binding sites for the antibodies.
For the determination of the pollutants, the beads are incubated with a mixture of the analyte-specific antibodies. The molecules on the surface of the beads and the free analyte in solution compete for the binding sites of the antibodies. Bead-bound antibodies can then be visualized via dye-labelled secondary antibodies. For read-out a flow cytometer is used to virtually separate the differently encoded beads. In order to obtain highly selective binding of the antibodies, we investigated different types of surface modifications to overcome unspecific binding, finding that a PEG-based surface is suitable to support our immunoassay format. The resulting multiplexing assay is appropriate to detect the marker substances in the low µg/L range.
Due to the demand of monitoring the water quality regarding emerging pollutants, such as drug residues, selective, high-throughput and multi-target analytical methods must be established. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affine and specific recognition of antibodies to target molecules. Batch-wise processing in microtiter plates allow the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex micro-bead based flow cytometric assay, which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core-silica-shell particles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica-shell creates a solid-support for the immunoassay: The target analytes, three drugs, carbamazepine, diclofenac and caffeine and the f ecal marker isolithocholic acid are covalently coupled to amino-groups on the surface via NHS-chemistry. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure. Finally, we could use SAFIA to assess the influent of treated and untreated waste water on the Douro river estuary in Portugal. The results of the analysis are comparable to ELISA. However, measurements could be carried out in 25% the time of analysis.