The analytical potential of a nanosecond laser ablation inductively coupled plasma mass spectrometer (ns-LA-ICP-SFMS) system, equipped with an ultra-fast wash-out ablation chamber, is critically investigated for fast and highly spatially resolved (∼μm) qualitative elemental distribution within single cells. Initially, a low surface roughness (< 10 nm) thin In–SnO2 layer (total coating thickness ∼200 nm) deposited on glass is employed to investigate the size, morphology and overlapping of laser-induced craters obtained at different laser repetition rates, making use of Atomic Force Microscopy (AFM). Conical craters with a surface diameter of about 2 µm and depths of about 100 nm were measured after a single laser shot. Furthermore, the influence of the sampling distance (i.e. distance between the sample surface and the inner sniffer of the ablation chamber) on the LA-ICP-MS ion signal wash-out time is evaluated. A significant decrease of the transient 120Sn+ ion signal is noticed after slight variations (±200 μm) around the optimum sampling position. Ultra-fast wash-outs (< 10 ms) are achieved reducing the aerosol mixing from consecutive laser shots even when operating the laser at high repetition rates (25 – 100 Hz). Fast and highly spatially resolved images of elemental distribution within mouse embryonic fibroblast cells (NIH/3T3 fibroblast cells) and human cervical carcinoma cells (HeLa cells), incubated with gold nanoparticles (Au NPs) and Cd-based quantum dots (QDs), respectively, are determined at the optimized operating conditions. Elemental distribution of Au and Cd in single cells is achieved using a high scanning speed (50 µm/s) and high repetition rate (100 Hz). The results obtained for the distribution of fluorescent Cd-based QDs within the HeLa cells are in good agreement with those obtained by confocal microscopy. The size, morphology and overlapping of laser-induced craters in the fixed cells are also investigated using AFM, observing conical craters with a surface diameter of about 2.5 µm and depths of about 800 nm after a single laser shot.
The analytical potential of a nanosecond laser ablation coupled plasma mass spectrometer (ns-LA-ICP-SFMS)system is investigated for fast and highly spatially resolved (~µm) elemental distribution within single cells. The size, morphology and overlapping of laser-induced craters has been investigated with Atomic Force Microscopy (AFM).
Force–distance curves have been acquired with an Atomic Force Microscope on polymethyl methacrylate with embedded glass spheres. The glass spheres provide a stiff substrate with an irregular and complex topography hidden underneath a compliant and even polymer film. This situation is a special case of a mechanical double-layer, which we examined in detail in previous experiments. Up to now uniform and non-uniform polymer films on an even substrate were examined. The film thickness on each point of the sample surface was known and force–distance curves could be averaged in groups according to the film thickness. In this way we were able to develop a semi empirical approach which allows describing the shape of averaged force–distance curves depending on the Youngs moduli of the involved materials and on the film thickness. In this experiment we reconstruct a hidden topography, i.e., we determine the polymer thickness on each point of the sample by analyzing single force–distance curves with our semi empirical equation. The accuracy reached by this approach permits to obtain a reconstruction of the shape and position of the embedded particles limited by a maximum detection depth. Single curves are also analyzed qualitatively in order to locate areas where the adhesion at the polymer/glass interface is weak or the two phases are detached.