Filtern
Dokumenttyp
- Zeitschriftenartikel (5)
- Vortrag (2)
Sprache
- Englisch (4)
- Deutsch (2)
- Französisch (1)
Schlagworte
- Benz[a]anthracene (BaA) (1)
- Benzo[a]pyrene (BaP) (1)
- Bestimmungsgrenze (1)
- CCQM-K126 (1)
- ELISA (1)
- Gas chromatography (GC) (1)
- Gesamtwasserprobe (1)
- Interlaboratory comparison (1)
- Isotope dilution (ID) (1)
- Limit of quantification (1)
Organisationseinheit der BAM
This study aimed to assess the measurement capabilities of participating National Metrology Institutes/ Designated Institutes (NMIs/DIs) and expert laboratories in determining of low-polarity organics in surface water. This comparison was organized by Government Laboratory, Hong Kong (GLHK).
At the CCQM Organic Analysis Working Group (OAWG) Meeting held in November 2012 in Hong Kong, GLHK initially proposed a CCQM key comparison and a parallel pilot study programme on pharmaceuticals in surface water. Further discussion at the CCQM Meeting held in April 2014 in Paris, the OAWG approved a CCQM Track C comparison (CCQM-K126) on low polarity pharmaceuticals in surface water. In the meeting, the programme was supported by more than six National Metrology Institutes/ Designated Institutes (NMIs/ DIs).
CCQM-K126 officially commenced in July 2014 and had registration from nine NMIs/DIs. Participants were provided two bottles (40 mL each) of surface water and were requested to determine the mass fraction of spiked carbamazepinein in surface water. The coordinator received nine sets of results from eight NMIs/DIs in February 2015. Apart from one using an immunoassay technique, all participants applied isotope dilution liquid chromatography-tandem mass spectrometry (ID-LCMS/MS) technique as their determination technique.
Solutions of organic analytes of known mass fraction are typically used to calibrate the measurement processes used to determine these compounds in matrix samples. Appropriate value assignments and uncertainty calculations for calibration solutions are critical for accurate measurements. Evidence of successful participation in formal, relevant international comparisons is needed to document measurement capability claims (CMCs) made by national metrology institutes (NMIs) and designated institutes (DIs). To enable NMIs and DIs to update or establish their claims, in 2015 the Organic Analysis Working Group (OAWG) sponsored CCQM-K131 "Low-Polarity Analytes in a Multicomponent Organic Solution: Polycyclic Aromatic Hydrocarbons (PAHs) in Acetonitrile".
Polycyclic aromatic hydrocarbons (PAHs) result from combustion sources and are ubiquitous in environmental samples. The PAH congeners, benz[a]anthracene (BaA), benzo[a]pyrene (BaP), and naphthalene (Nap) were selected as the target analytes for CCQM-K131. These targets span the volatility range of PAHs found in environmental samples and include potentially problematic chromatographic separations. Nineteen NMIs participated in CCQM-K131. The consensus summary mass fractions for the three PAHs are in the range of (5 to 25) μg/g with relative standard deviations of (2.5 to 3.5) %.
Successful participation in CCQM-K131 demonstrates the following measurement capabilities in determining mass fraction of organic compounds of moderate to insignificant volatility, molar mass of 100 g/mol up to 500 g/mol, and polarity pKow < −2 in a multicomponent organic solution ranging in mass fraction from 100 ng/g to 100 μg/g: (1) value assignment of primary reference standards (if in-house purity assessment carried out), (2) value assignment of single and/or multi-component organic solutions, and (3) separation and quantification using gas chromatography or liquid chromatography.
Under the auspices of the Organic Analysis Working Group (OAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a key comparison, CCQM K55.b, was coordinated by the Bureau International des Poids et Mesures (BIPM) in 2010/2011. Nineteen national measurement institutes and the BIPM participated. Participants were required to assign the mass fraction of aldrin present as the main component in the comparison sample for CCQM-K55.b which consisted of technical grade aldrin obtained from the National Measurement Institute Australia that had been subject to serial recrystallization and drying prior to sub-division into the units supplied for the comparison.
Aldrin was selected to be representative of the performance of a laboratory's measurement capability for the purity assignment of organic compounds of medium structural complexity [molar mass range 300 Da to 500 Da] and low polarity (pKOW < -2) for which related structure impurities can be quantified by capillary gas phase chromatography (GC).
The key comparison reference value (KCRV) for the aldrin content of the material was 950.8 mg/g with a combined standard uncertainty of 0.85 mg/g. The KCRV was assigned by combination of KCRVs assigned by consensus from participant results for each orthogonal impurity class. The relative expanded uncertainties reported by laboratories having results consistent with the KCRV ranged from 0.3% to 0.6% using a mass balance approach and 0.5% to 1% using a qNMR method.
The major analytical challenge posed by the material proved to be the detection and quantification of a significant amount of oligomeric organic material within the sample and most participants relying on a mass balance approach displayed a positive bias relative to the KCRV (overestimation of aldrin content) in excess of 10 mg/g due to not having adequate procedures in place to detect and quantify the non-volatile content–specifically the non-volatile organics content–of the comparison sample.
There was in general excellent agreement between participants in the identification and the quantification of the total and individual related structure impurities, water content and the residual solvent content of the sample.
The comparison demonstrated the utility of 1H NMR as an independent method for quantitative analysis of high purity compounds. In discussion of the participant results it was noted that while several had access to qNMR estimates for the aldrin content that were inconsistent with their mass balance determination they decided to accept the mass balance result and assumed a hidden bias in their NMR data. By contrast, laboratories that placed greater confidence in their qNMR result were able to resolve the discrepancy through additional studies that provided evidence of the presence of non-volatile organic impurity at the requisite level to bring their mass balance and qNMR estimates into agreement.
The European Water Framework Directive 2000/60/EC requires monitoring of organic priority pollutants in so-called whole water samples, i.e. in aqueous nonfiltered samples that contain natural colloidal and suspended particulate matter. Colloids and suspended particles in the liquid phase constitute a challenge for sample homogeneity and stability. Within the joint research project ENV08 ‘‘Traceable measurements for monitoring critical pollutants under the European Water Framework Directive 2000/60/EC’’, whole water test materials were developed by spiking defined amounts of aqueous slurries of ultrafinely milled contaminated soil or sediment and aqueous solutions of humic acid into a natural mineral water matrix. This paper presents the results of an European-wide interlaboratory comparison (ILC) using this type of test materials. Target analytes were tributyltin, polybrominated diphenyl ethers and polycyclic aromatic hydrocarbons in the ng/L concentration range. Results of the ILC indicate that the produced materials are sufficiently homogeneous and stable to serve as samples for, e.g. proficiency testing or method validation. To our knowledge, this is the first time that ready-to-use water materials with a defined amount of suspended particulate and colloidal matter have been applied as test samples in an interlaboratory exercise. These samples meet the requirements of the European Water Framework Directive. Previous proficiency testing schemes mainly employed filtered water samples fortified with a spike of the target analyte in a water-miscible organic solvent.
Afin de garantir la qualité des eaux en Europe, la Commission Européenne a demandé aux États Membres, de leur fournir des résultats de mesure comparables et traçables pour l’analyse des polluants critiques. Devant ces enjeux considérables pour la protection de l’environnement, l’apport de la métrologie est nécessaire pour améliorer la fiabilité des analyses et permettre la comparabilité des résultats. C’est pourquoi, le projet de recherche européen Euramet/EMRP/ENV08 « Traçabilité des mesures pour la surveillance des polluants critiques de la DCE, Directive Cadre européenne sur l’Eau (2000/60/CE) », financé par l’EMRP, avait pour objectif de fournir des éléments pour la mise en place d’une base métrologique. Des méthodes de référence primaires permettant d’analyser des substances dangereuses prioritaires y sont développées pour répondre aux exigences de la DCE en termes de niveaux de performance (limites de quantification et incertitudes). Les hydrocarbures aromatiques polycycliques (HAP), substances dangereuses prioritaires « orphelines » de méthodes DCE compatibles, font partie des polluants ciblés par le projet. Le développement et la validation de la méthode d’analyse des HAP dans l’eau totale ont été réalisés. La méthode qui satisfait au mieux les exigences de la DCE en termes de concentrations et d’incertitudes accessibles est l’extraction en phase solide (SPE) sur un support disque suivie d’une analyse par dilution isotopique associée à la chromatographie en phase gazeuse couplée à la spectroscopie de masse (DI-CG/SM).