Filtern
Dokumenttyp
- Zeitschriftenartikel (21)
- Posterpräsentation (6)
- Vortrag (4)
Schlagworte
- BAMline (3)
- Compound refractive lens (3)
- CXC (2)
- Color X-ray camera (2)
- Micro-PIXE (2)
- SR-microXRF (2)
- Synchrotron (2)
- Synchrotron radiation (2)
- X-ray fluorescence (2)
- XRF (2)
Organisationseinheit der BAM
- 6 Materialchemie (3)
- 6.3 Strukturanalytik (3)
Eingeladener Vortrag
- nein (4)
We present a new high resolution X-ray imager based on a pnCCD detector and a polycapillary optics. The properties of the pnCCD like high quantum efficiency, high energy resolution and radiation hardness are maintained, while color corrected polycapillary lenses are used to direct the fluorescence photons from every spot on a sample to a corresponding pixel on the detector. The camera is sensitive to photons from 3 to 40 keV with still 30% quantum efficiency at 20 keV. The pnCCD is operated in split frame mode allowing a high frame rate of 400 Hz with an energy resolution of 152 eV for Mn Kα (5.9 keV) at 450 kcps. In single-photon counting mode (SPC), the time, energy and position of every fluorescence photon is recorded for every frame. A dedicated software enables the visualization of the elements distribution in real time without the need of post-processing the data. A description of the key components including detector, X-ray optics and camera is given. First experiments show the capability of the camera to perform fast full-field X-Ray Fluorescence (FF-XRF) for element analysis. The imaging performance with a magnifying optics (3×) has also been successfully tested.
With the increase in the awareness of the public in the environmental impact of oil shale utilization, it is of interest to reveal the mobility of potentially toxic trace elements in spent oil shale. Therefore, the Cr and As oxidation state in a representative Jordanian oil shale sample from the El-Lajjoun area were investigated upon different lab-scale furnace treatments. The anaerobic pyrolysis was performed in a retort flushed by nitrogen gas at temperatures in between 600 and 800 °C (pyrolytic oil shale, POS). The aerobic combustion was simply performed in porcelain cups heated in a muffle furnace for 4 h at temperatures in between 700 and 1000 °C (burned oil shale, BOS). The high loss-on-ignition in the BOS samples of up to 370 g kg–1 results from both calcium carbonate and organic carbon degradation. The LOI leads to enrichment in the Cr concentrations from 480 mg kg–1 in the original oil shale up to 675 mg kg–1 in the ≥850 °C BOS samples. Arsenic concentrations were not much elevated beyond that in the average shale standard (13 mg kg–1). Synchrotron-based X-ray absorption near-edge structure (XANES) analysis revealed that within the original oil shale the oxidation states of Cr and As were lower than after its aerobic combustion. Cr(VI) increased from 0% in the untreated or pyrolyzed oil shale up to 60% in the BOS ash combusted at 850 °C, while As(V) increased from 64% in the original oil shale up to 100% in the BOS ash at 700 °C. No Cr was released from original oil shale and POS products by the European compliance leaching test CEN/TC 292 EN 12457-1 (1:2 solid/water ratio, 24 h shaking), whereas leachates from BOS samples showed Cr release in the order of one mmol L–1. The leachable Cr content is dominated by chromate as revealed by catalytic adsorptive stripping voltammetry (CAdSV) which could cause harmful contamination of surface and groundwater in the semiarid environment of Jordan.
For quantitative SRXRF measurements the angle of incidence of the incoming X-ray beam is an important factor. When the sample is focused by a long-range-microscope, the determination of the angle can be automatized using a simple algorithm. This was developed to improve the orientation of especially round or ornate samples. As a side effect the three dimensional surface can be reconstructed, too.
Compact pnCCD-based X-ray camera with high spatial and energy resolution: a color X-ray camera
(2011)
For many applications there is a requirement for nondestructive analytical investigation of the elemental distribution in a sample. With the improvement of X-ray optics and spectroscopic X-ray imagers, full field X-ray fluorescence (FF-XRF) methods are feasible. A new device for high-resolution X-ray imaging, an energy and spatial resolving X-ray camera, is presented. The basic idea behind this so-called 'color X-ray camera' (CXC) is to combine an energy dispersive array detector for X-rays, in this case a pnCCD, with polycapillary optics. Imaging is achieved using multiframe recording of the energy and the point of impact of single photons. The camera was tested using a laboratory 30 µm microfocus X-ray tube and synchrotron radiation from BESSY II at the BAMline facility. These experiments demonstrate the suitability of the camera for X-ray fluorescence analytics. The camera simultaneously records 69696 spectra with an energy resolution of 152 eV for manganese Kα with a spatial resolution of 50 µm over an imaging area of 12.7 × 12.7 mm². It is sensitive to photons in the energy region between 3 and 40 keV, limited by a 50 µm beryllium window, and the sensitive thickness of 450 µm of the chip. Online preview of the sample is possible as the software updates the sums of the counts for certain energy channel ranges during the measurement and displays 2-D false-color maps as well as spectra of selected regions. The complete data cube of 264 × 264 spectra is saved for further qualitative and quantitative processing.
This manuscript reviews the most used optical systems for X-ray microprobes and summarizes the experiences in research with synchrotron radiation as well as with X-ray tube generators.
The need for smaller beam spot sizes for various applications and the unique properties of X-rays have induced a remarkable and fast development in X-ray optical systems. These systems are divided into three main categories: diffractive, reflective and refractive. Examples of the three will be covered in this paper, highlighting the properties that allow having spot sizes down to sub-micrometer regime.
However, the extraordinary capabilities of such systems are always relative. Therefore, an overview of the techniques that use such optical systems will be given, emphasizing their applicability on several case studies.
Several glazed ceramic fragments (XVIth to XVIIIth centuries) from two production centers in Portugal (Coimbra and Lisbon) were the object of this study. The ones from Coimbra comprise two sets of samples: faiences and tiles. The ones from Lisbon are only tiles (azulejos, in Portuguese). The three main divisions of such pieces are the ceramic support (body), glaze and surface decoration. The system decoration/glaze is not easy to investigate, due to the high heterogeneity resulting from the mixing procedures and firing temperatures used. Moreover, the ability of the pigment to diffuse into the base glaze varies depending on the composition of both the pigment and the glaze in terms of fusibility. In order to raster these effects, high resolution techniques are required. In this work, synchrotron micro-X-ray fluorescence (µ-XRF) analysis was performed to monitor the profiles of the characteristic elements from the colors used and the glaze in well prepared cross-sections of the samples. Key elements are: Co for blue, Mn for purple, Cu for green, Sb for yellow, Pb for the glaze and Fe for the body. The major difference observed is that faiences have glaze thicknesses between 150 and 200 µm and tiles have glaze thicknesses between 350 and 400 µm. Furthermore, in faiences all the pigments except the yellow ones are well dispersed into the glassy matrix, while in tiles, all of them are just partially diffused throughout the glaze. However, differences between the tiles from Coimbra and Lisbon were observed. In the samples from Lisbon, a higher intake from the pigment throughout the glaze is observed.