Due to the increasing presence of microplastic particles (MP) in the Environment and the unknown risks arising from them, there is an urgent need for analytical methods that allow for an efficient identification and quantification of microplastics (MP), i.e. particles < 5 mm, in environmental samples. So far, mostly timeconsuming (micro) infrared or micro-Raman spectroscopic methods are applied. Here an faster alternative Approach is presented based on a Raman processspectrometer with fiber-optical probes in combination with multivariate data analysis.
Abstract. Biodiesel quality control is a relevant issue as biodiesel properties influence diesel engine performance and integrity. Within the European Metrology Research Program (EMRP) ENG09 project “Metrology for Biofuels”, an on-line /at-site suitable near-infrared spectroscopy (NIRS) method has been developed in parallel with an improved EN14110 headspace GC analysis method for methanol in biodiesel. Both methods have been optimized for a methanol content of 0.2 mass% as this represents the maximum limit of methanol content in FAME according to EN 14214:2009. The NIRS method is based on a mobile NIR spectrometer equipped with a fiber-optic coupled probe. Due to the high volatility of methanol, a tailored air-tight adaptor was constructed to prevent methanol evaporation during measurement. The methanol content of biodiesel was determined from evaluation of NIRS spectra by Partial Least Squares Regression (PLS). Both GC analysis and NIRS exhibited a significant dependence on biodiesel feedstock. The NIRS method is applicable to a content range of 0.1 % (m/m) to 0.4 % (m/m) of methanol with uncertainties at around 6% relative for the different feedstocks. A direct comparison of headspace GC and NIRS for samples of FAMEs yielded that the results of both methods are fully compatible within their stated uncertainties.
With a more and more general acceptance of accreditation in the field of reference materials production, and an ever increasing number of RMP accredited, accreditation bodies face applications from RMP active in the field of qualitative RM production.
While (the still valid and used for accreditation purposes) ISO Guides 34 and 35 describe in detail requirements applicable to RMP dealing with quantitative RM, accreditation bodies normally claim lack of normative requirements with respect to quantitative RM. The new ISO 17034:2016 which will be introduced in the accreditation practice over the next two to three years solves the problem pragmatically, allowing strategies for RM certification other than those for (purely) quantitative materials.
In fact, both ISO Guide 34 and the new ISO 17034 are written in a form that, at least for the overwhelming majority of requirements, may be applied to RMP of both qualitative and quantitative RM. Peculiarities may occur in homogeneity and stability testing, and the uncertainty of a purely qualitative result is still under discussion. The problem of traceability might be solved for most of the application fields considered.
The talk gives an overview of the specific problems encountered, and provides some possible solutions both for homogeneity and stability testing, the expression of uncertainty, and the statement of traceability in certificates.
Qualitative reference materials (RM) cover a wide range of the overall RM market. Proficiency testing providers attract up to a thousand of participants in PT schemes purely oriented on qualitative results. The RM used for these kinds of PT are poorly regulated, nevertheless with a more and more general acceptance of accreditation in the field of RM production and PT provision, there is an ever increasing interest in assessing producers and providers according to rules already well accepted in the field of quantitative analysis.
The basic governing document, ISO 17034:2016, is written in a form that, at least for the overwhelming majority of requirements, may be applied to both qualitative and quantitative RM. However, problems remain. In particular, the expression of uncertainty of a purely qualitative result is still unresolved, and under discussion, the latter now lasting already dozens of years.
Some handles would be needed. In the poster, existing approaches and some pragmatic, new ways to tackle the problem are displayed and discussed.
Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which require excessive calibration effort. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environ¬ments for advanced process monitoring and control, as demonstrated within the European Union’s Horizon 2020 project CONSENS.
We present a range of approaches for the automated spectra analysis moving from conventional multivariate statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants or derivatives and robust automation schemes.