The reliability in measurement results obtained during environmental monitoring is crucial for the assessment and further planning of remediation efforts on the respective contaminated sites by the responsible authorities. A case study concerned with groundwater contaminated with perchloroethylene, trichloroethylene and 1,1,2-trichlorotrifluoroethane including their degradation products which involves private contract laboratories and an independent provider of quality assurance (QA) is presented. The experience gained with biannual monitoring campaigns over 14 years indicates that the selection of contractors on basis of accreditation status and successful performance in interlaboratory comparisons are not sufficient. Rather the auditing of the contractors by the QA provider prior to each campaign and the crosschecking of selected monitoring samples by the QA provider led to a lasting improvement of reliability in the contractors' measurement results. A mean deviation of 20% from the reference value determined by the QA provider for the crosschecked samples was reached.
Mycotoxins are important non-anthropogenic food and feed contaminants, which can be present on almost every agricultural commodity. Effective consumer protection therefore essentially depends on food surveillance by reliable quantitative analysis enabled by appropriate quality control. Certified (matrix) reference materials (CRMs) are versatile tools to support Quality assurance. However, in the case of ochratoxin A (OTA), a hepato- and nephrotoxic mycotoxin, which is regulated in various foods, there is a lack of suitable CRMs. This lack has now been overcome by the development of two European Reference Materials (ERM®) for the Determination of OTA in roasted coffee (ERM®-BD475) and red wine (ERM®-BD476). This article discusses the material preparation process as well as the results of homogeneity and stability testing. Furthermore, the results of the inhouse certification studies carried out at BAM Federal Institute for Materials Research and Testing are presented and discussed. Interlaboratory comparison studies involving selected expert laboratories with documented Expertise in the field of mycotoxin analysis were conducted to confirm the certified values determined by BAM. The certified ochratoxin A values and their corresponding expanded uncertainties (k = 2) were assigned in full compliance with the requirements of ISO Guide 35 and are as follows:
(6.0 ± 0.6) µg kg-1 for roasted coffee, ERM®-BD475, and (0.52 ± 0.11) µg L-1 for red wine, ERM®-BD476.
The performance of twelve laboratories with previously established proficiency in the determination of the mineral oil content in a fresh water sediment is described. The summation parameter total petrol hydrocarbon (TPH) is defined according to ISO 16703:2004 with regard to the sample preparation to be applied, the flame ionisation detection (FID) and the boiling range of C10C40 to be integrated. Comprehensive tests of homogeneity and stability have been carried out on the candidate material using appropriate models. The outcome of the study served as the basis for the certification of the candidate reference material as ERM-CC015a. The certified mass fraction is 1,820±130mgkg-1 and traceability was established by using an appropriate calibration standard certified for the mass fraction of C10C40. The interlaboratory scatter of measurement results in this exercise can largely be explained by the variability of the individual calibrations based on this common calibration standard.
Ethanol/water solutions as certified reference materials for breath alcohol analyzer calibration
(2010)
The Federal Institute for Materials Research and Testing (BAM), Germany, has issued a series of large volume ethanol in water certified reference materials (CRMs), primarily developed for the calibration of evidential breath alcohol analyzers in Germany. The certified parameter is the ethanol mass concentration at 20 °C. When used in a wet bath simulator, the solutions deliver gas samples that meet the requirements set by the Organization of Legal Metrology for calibration of breathalyzers. The materials were prepared gravimetrically by spiking of ethanol into water in single 5 L units. A complete uncertainty budget for the preparation process has been established. The purity of the commercial ethanol stock solution was identified to be the main source of uncertainty. For stability and homogeneity measurements and for the verification of the gravimetric mass concentration of the CRMs, a robust high-precision gas chromatography, with flame-ionization detection method for ethanol determination in aqueous samples was developed and validated. The good performance of this method has been demonstrated in several international comparisons organized by the Consultative Committee for Amount of Substance-Metrology in Chemistry at the International Bureau of Weights and Measures.
HBCD stereoisomer pattern in mirror carps following dietary exposure to pure Gamma-HBCD enantiomers
(2010)
Certified reference materials (CRMs) are a versatile tool for quality assurance in the chemical laboratory. In the case of acrylamide analysis, the availability of appropriate materials was rather limited. This lack of acrylamide matrix CRMs has now been overcome by the development of two European reference materials (ERM) for the determination of acrylamide in food (crispbread, ERM-BD272, and rusk, ERM-BD274). This article describes the preparation of the materials, provides the results of the homogeneity and stability studies, and presents and discusses the outcome of the certification studies. Expert laboratories from different European countries took part in the certification studies using various analytical methods. The acrylamide mass fractions were certified to 980 µg kg-1 for crispbread and 74 µg kg-1 for rusk.
Levels of α-, β-, and γ-hexabromocyclododecane (HBCD) were determined in pooled eggs from herring gulls (Larus argentatus) sampled on three bird sanctuaries near the German North Sea coast between 1988 and 2008 (Mellum and Trischen) and the German Baltic Sea coast between 1998 and 2008 (Heuwiese) and archived by the German Environmental Specimen Bank. Pressurized fluid extraction, gel permeation chromatography, and LCMS/MS using 13C12-labelled isotope standards and a chiral column were applied. α-HBCD was the dominating diastereomer and ranged between 3.7 and 107 ng g-1 lw while β- and γ-HBCD were throughout close to LOQ. The highest α-HBCD concentration was found in eggs from Mellum sampled in the year 2000. Interestingly, HBCD in eggs from the three islands displayed similar time courses with levels increasing to a peak contamination around 2000 and decreasing levels ever since. Chiral signatures of α-HBCD in eggs differed among the islands but indicated a preferential enrichment of the first eluting enantiomer (-)-α-HBCD.
The degradation kinetics of the Alternaria mycotoxin tenuazonic acid (l-TA) in aqueous buffer were studied over a period of 4 months at different pH levels (3.5 and 7.0) and temperatures (4, 25 and 40°C). l-TA and its degradation products were quantified by newly developed high-performance liquid chromatography methods with UV or electrospray multistage mass spectrometry detection. At pH 3.5, significant degradation occurred at 25 and 40°C, the respective l-TA half-lives being 73.8±0.4 and 14.0±0.1 days. Two degradation processes, epimerization and hydrolysis, were evaluated kinetically. The hydrolytically formed iso-deacetyl TA (iso-DTA, epimeric mixture) was found to be the stable end product of l-TA degradation under the conditions of this study. This indicates that iso-DTA as well as the l-TA epimer u-TA are formed in aqueous beverage matrices.