Filtern
Dokumenttyp
Sprache
- Englisch (3)
Schlagworte
- Acoustic signal processing (1)
- Eddy current testing (1)
- NDT reliability (1)
- Non destructive testing (1)
- Polymers (1)
- Radiography (1)
- Spectrometers (1)
- Terahertz time domain spectroscopy (1)
- Time of flight diffraction (1)
- Ultrasonic (1)
The inspection of the sealing weld is an important phase for the evaluation of the acceptability of final disposal canister, but the weld is only a part of the 3D shielding of copper shell. The main tasks for reliable NDT evaluation requires an extensive evaluation of the parameters which contains typical inspection related items like repeatability, S/N ratio, POD, setting up the equipment for inspection, and all practices for inspections. The other parameters are material parameters, their variation must be taken into account in the evaluation of NDT reliability. Further parameters include human factors, i. e. human inspectors and their interaction with technical systems; their effects were studied on an example of the evaluation of eddy current data. Final parameters are related to evaluation of detected defects, which means sizing and base for acceptance and this can be done in different ways. Some examples are given and results are compared with different methods for instance between radiographic testing and ultrasonic testing by raw data analysis and PA-SAFT results. Also, preliminary curves for the evaluation of metallographic results of 55 defects will be shown by EB weld measurements. Some practical items concerning copper inspections will be also discussed related to acceptability.
A time domain spectrometer in the range of 0.5–2 THz was used for time of flight (ToF) measurements of THz pulses for imperfection detection in non metallic materials. The measurements were performed in comparison to the established ultra sound pulse echo (PE) and time of flight diffraction (ToFD) technique. No coupling agent and no contact to the surface is required for THz ToFD measurements. Plastic test specimen with notches, voids and drilled side holes were used to study reflected and diffracted response signals. No major differences were observed between the UT and THz ToFD records for the first surface of the notches, voids and holes. Additionally to the UT records also signals were obtained from its back side and a second raw of holes. The THz measurement is fast and has the potential to substitute UT applications in some industrial areas. Within the German project 'Handheld' the potential for miniaturization of the time domain equipment is explored for efficient application.