Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (30)
- Zeitschriftenartikel (5)
- Beitrag zu einem Sammelband (4)
- Posterpräsentation (2)
- Vortrag (1)
Sprache
- Deutsch (23)
- Englisch (18)
- Mehrsprachig (1)
Schlagworte
- Ultrasonic testing (8)
- Phased array (5)
- SAFT (4)
- Aktive Thermografie (2)
- CFK (2)
- Erprobung an Rohrtestkörpern (2)
- Ersatz von konventioneller Prüftechnik durch Matrixarrays (2)
- Faserverbundwerkstoffe (2)
- GFK (2)
- Luftultraschall (2)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (9)
- 8.4 Akustische und elektromagnetische Verfahren (7)
- 8.0 Abteilungsleitung und andere (4)
- 9 Komponentensicherheit (2)
- 9.0 Abteilungsleitung und andere (2)
- 9.4 Integrität von Schweißverbindungen (2)
- 7 Bauwerkssicherheit (1)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (1)
Eingeladener Vortrag
- nein (1)
The spatial resolution in ultrasonic testing as a wave phenomenon in nature is limited to a
certain fraction of the wavelength, usually defined to be close to the Rayleigh criterion. In case of
complicated reflector surfaces – such as stress corrosion cracking - this limitation prevents an exact
visualization of the defect shape. There exist a few approaches to improve the spatial resolution, whose
reconstruction quality all in common also depend on the achieved signal-to-noise ratio of the raw data. In this
work we present a specific SAFT analysis, in which a high number of different angles of incidence produce a
sufficiently high number of different reflections at the crack edges resulting in an improved SNR. In doing
so, we reconstruct a coherent crack structure. First investigations were made at artificially simulated crack
configurations with different contours and curvatures in flat and cylindrical test blocks. The measurements
results visualized by representative scans – show details of crack design and crack orientation. We also will
present a comparison of the SAFT analysis between modelling and phased array measurements.
SAFT für die Rissflächenanalyse - Vergleich von Modellrechnungen und Gruppenstrahlermessungen
(2009)
Faserverbundwerkstoffe wie kohlefaserverstärkte Kunststoffe CFK sind vergleichsweise schwer mit Ultraschall zu prüfen, weil die starke Dämpfung, der inhomogene Aufbau und die akustische Anisotropie die Wellenausbreitung behindern bzw. komplizieren. Die Folge ist, dass die Ansprüche an die Prüfung oft stark reduziert werden müssen. Die vorgestellte Prüftechnik nutzt die Möglichkeiten der räumlichen Fokussierung und des zweidimensionalen Winkelscans von Matrix Phased Array Prüfköpfen MPA in Kombination mit Echosignalüberlagerungsalgorithmen für eine substantielle Verbesserung der Auflösung und des Signal-Rausch-Verhältnisses. Sowohl bei der Ansteuerung des MPA als auch bei der Auswertung wird die Anisotropie des Werkstoffs berücksichtigt. Das MPA wird über die Oberfläche bewegt und an einer Anzahl von Messpunkten werden zweidimensionale Winkelscans durchgeführt. Das Ergebnis sind räumliche Echohöhenverteilungen, aus denen Schnittbilder oder auch Volumendarstellungen erzeugt werden können.
Anhand von Messungen an CFK-Platten mit Flachbodenbohrungen KSR 1 und 2 sollen die Empfindlichkeit und das Auflösungsvermögen der Prüftechnik demonstriert werden. Weiterhin werden Untersuchungen an Impaktschäden gezeigt, die typischerweise bei Faserverbundwerkstoffen bei starken punktförmigen Belastungen auftreten.
Hollow axle inspection can be performed without demounting the axles and without dismantling the wheels and the brake discs by using the drilling for the scan. To increase inspection reliability and inspection speed, the application of phased array systems instead of conventional probes is a good choice. For solid shaft inspection phased array setups became standard in the recent years. Nevertheless, for hollow axle inspection typically a number of conventional probes rotating through the axles drilling are applied.
The new approach uses an electronically steered rotating sound field from a phased array for the circumferential scan. This is realized by a cone shaped phased array which operates in immersion technique. That allows a significant increase in inspection speed and a reduction of the mechanical effort of the inspection system. The inspection can be carried out by a linear movement of the probe setup along the axles drilling. Applying additional focal laws allows exact inclination and focusing of the sound beam in the plane vertical to the specimen axis to concentrate the sound in the zones close to the external surface. An additional focus in the plane of incidence increases overall resolution and sensitivity.
The cone type phased array probe has been optimized to detect transversal flaws in and close to the outer surface of the hollow axle with orientation in the radial-radial plane. The prototype probe system, sound field simulations and measurement results are presented.
Klebverbindungen im modernen Hochbau können helfen, innovative ästhetische Bedürfnisse im Fassadenbau umzusetzen, technologische Verbesserungen zu erreichen, aber auch die Wechselwirkung von Gebäuden mit der Umwelt unter energetischen Aspekten zu optimieren. Aufgrund der hohen sicherheitstechnischen Bedeutung gibt es hohe Anforderungen an die Leistungsfähigkeit, Dauerhaftigkeit und die Gütesicherheit.
Mit einer zerstörungsfreien praxistauglichen Prüftechnik, die eine sichere Überprüfung der Integrität von Glas-Metall Klebverbindungen im Ingenieurhochbau gewährleistet, kann sowohl ein wichtiger Beitrag zur Qualitätssicherung bei der Herstellung von Fassadenelementen aber auch bei der späteren Bauwerksüberwachung im Verlauf der Nutzungsdauer geleistet werden. Für eine Beurteilung der Qualität der Verbundfuge (z.B. bezgl. Standsicherheit) sind dabei Aussagen zur Homogenität der Verbundfuge, zum adhäsiven und kohäsiven Verbundverhalten gefordert. Hierzu besteht aktuell insbesondere Bedarf an zerstörungsfreien praxisgerechten, hoch ortsauflösenden und möglichst bildgebenden Untersuchungsverfahren.
Es wird mit einem Matrixarray und mit konventionellen Winkelprüfköpfen eine Prüftechnik vorgestellt, mit der die Wechselwirkung zwischen Ultraschallwelle und Fehlstelle in der Klebefuge untersucht wird. Hierbei ist das erste Untersuchungsziel, mit einer angepassten Ultraschall-Prüftechnik mögliche Inhomogenitäten oder Schädigungsstellen in der geklebten Glas-Metall Verbindung zu detektieren.
Über diese qualitativen Aussagen hinaus werden weiterführende Informationen über die flächenhafte Ausdehnung und den Ort einer mangelnden Klebung ermittelt. Dazu werden die Messwerte zusammen mit den Positionen des Ultraschallprüfkopfs aufgezeichnet. Mit Hilfe einer bildhaften Auswertung der gemessenen Ultraschallechos in Abhängigkeit vom Prüfkopfort werden die Möglichkeiten einer detaillierten Integritätsanalyse der Glas-Metall Klebschicht dargestellt. In diesem Beitrag werden experimentelle Prüfergebnisse vorgestellt, die im Sinne einer Verfahrensvalidierung an einem speziellen Beispielprobekörper zur Nachstellung einer SSG-Verglasung (ermittelt wurden und die Detektion fehlerhafter Klebestellen in einer Glas-Metall-Klebverbindung zum Ziel haben.