Fatigue testing in the VHCF ränge requires testing machines with increased frequencies. However, application of energy-saving resonance testing leads to a linkage between test frequency and specimen Parameters. The frequency ränge and the available forces of the testing machine are limiting possible specimen dimensions.
Electrodynamic shakers combine test frequencies up to 4000 Hz with forces in the kN range. Thus, a relatively wide range of tests is possible which allows studying the influence of specimen size on VHCF behaviour.
Electrodynamic shakers as well as the respective Computer control Systems and Vibration measurement techniques are well established in scientific and technical applications. We present results of a first study of VHCF testing on electrodynamic shakers conducted at BAM. Test frequency, specimen size and stress levels have been varied. One goal is to balance the needs of materials testing with the Standard test Systems of environmental Simulation to provide a powerful and flexible tool for very high cycle fatigue testing. Further investigation to optimize the technique is required.