A method for the determination of 22 trace impurities in solar grade silicon after dissolution in a mixture of HF and HNO3 and subsequent matrix evaporation is reported. The presented method involves a simple, inexpensive, one-vessel sample preparation apparatus design. The recoveries of B, Na, Mg, Al, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Mo, Sb, W, and Tl at 250 µg kg-1 level are in the range of 93 to 108%. After careful selection of monitored isotopes and their respective resolutions, a sector field mass spectrometer has been used to carry out the measurements. Limits of determination down to 120 ng kg-1 have been obtained using a calibration by three-point standard addition. The method was tested on diluted NIST SRM 57b silicon powder as well as on synthetic test samples and also applied successfully on raw solar grade silicon samples in an interlaboratory comparison including NAA.
The Federal Institute for materials research and testing (BAM)in cooperation with the Fachhochschule Münster has developed a new certified polymeric reference material, BAM-H010. The reference material consists of acrylonitrile–butadiene–styrene terpolymer (ABS) and has been doped with different contents of the elements Br, Cd, Cr, Hg and Pb. The monitoring of these elements is demanded in the EU directive 2002/95/EG, commonly referred to as RoHS. We have shown that the uncertainty contribution of the thermal long-term stability (ustability) is negligible compared to the contribution to the uncertainty caused by the method used for the characterization of the elemental content and the batch inhomogeneity (uhomogeneity). The stability of theABS material during exposure of the samples with hard X-radiation leads to a degradation of the ABS matrix with either long- or short-chain products.
A new setup for fast spatially resolved measurements of elemental trace amounts under total reflection conditions using a new colour X-ray camera is described. Samples prepared on conventional total reflection X-ray fluorescence (TXRF) reflectors were measured at BESSY II synchrotron. A spatial resolution of 50 × 50 µm² was obtained, while the required time for the investigation of a 10 × 10 mm² sample is 30 seconds. The set-up is up to 350 times faster than conventional X-ray fluorescence systems for elemental traces. The major components of the X-ray camera are polycapillary optics and a pn-CCD chip with an active area of 13 × 13 mm². This area is divided into 264 × 264 pixels of 48 × 48 µm². A full X-ray spectrum with a resolution of 152 eV @ 5.9 keV and a chip temperature of 246 K is recorded for each pixel. The chip has a read-out rate of 400 Hz.
Boron carbide is widely used as industrial material, because of its extreme hardness, and as a neutron absorber. As part of a round-robin exercise leading to certification of a new reference material (ERM-ED102) which was demanded by the industry we analysed nitrogen in boron carbide by inert gas fusion analysis (GFA) and instrumental photon activation analysis (IPAA) using the 14N(γ,n)13N nuclear reaction. The latter approach is the only non-destructive method among all the methods applied. By using photons with energy below the threshold of the 12C(γ,n)11C reaction, we hindered activation of matrix and other impurities. A recently installed beam with a very low lateral activating flux gradient enabled us to homogeneously activate sample masses of approximately 1 g. Taking extra precautions, i.e. self-absorption correction and deconvolution of the complex decay curves, we calculated a nitrogen concentration of 2260 ± 100 µg g-1, which is in good agreement with our GFA value of 2303 ± 64 µg g-1. The values are the second and third highest of a rather atypical (non-S-shape) distribution of data of 14 round-robin participants. It is of utmost importance for the certification process that our IPAA value is the only one not produced by inert gas fusion analysis and, therefore, the only one which is not affected by a possible incomplete release of nitrogen from high-melting boron carbide.
We performed spatially resolved synchrotron-induced x-ray fluorescence analyses (SY-XRF) of five silverpoint drawings from the famous `Karlsruhe sketchbook´ and a silverpoint, which is assumed to be an original one used by the Renaissance artist Hans Baldung Grien (1484-1545) himself. The silverpoint, one out of a very small number of ancient styli conserved nowadays, is fixed on the so-called `Karlsruhe sketchbook´. Measurements were executed at the FLUO-TOPO beamline at the electron storage ring ANKA. It has been shown, that SY-XRF at this beamline is nondestructive and sensitive enough for the analysis of minor and major elements in the silver strokes. This study provides new insights into this graphical technique and ancient drawing instruments: results are that three drawings have been created with a common type of silverpoint containing about (10.4 ± 0.7) wt% of Cu. In all the cases, Hg at a 10% level by weight was identified in the strokes. Presence of Hg is not due to the original silver alloy, but is a result of a general alteration phenomenon of silverpoint drawings. This fact is confirmed by the analysis of the original silverpoint, which contains only small traces of Hg. The result for the copper content of the silverpoint (10.4 ± 1.7) wt% is in good agreement with that of these three drawings. It is supposable that the silverpoint found attached today served for the creation of the corresponding drawings. Moreover, the graphical technique of Baldung is found to be continual over three decades. Only one very late drawing dated to 1543 was probably realized with another silverpoint, containing about 3 wt% of Cu. This difference in the chemical composition of drawings from the late period might be used as a more precise dating indicator of Baldung drawings that are not clearly attributed to a certain period.
New analyses of a series of very rare silverpoint drawings that were executed by Rembrandt Harmensz. van Rijn (16061669) which are kept today in the Kupferstichkabinett (Museum of Prints and Drawings) of the State Museums of Berlin are reported here. Analysis of these drawings requires particular attention because the study has to be fully non-destructive and extremely sensitive. The metal alloy on the paper does not exceed some hundreds of µg/cm². Therefore, synchrotron radiation induced X-ray fluorescence (SR-XRF) is together with external micro-proton-induced X-ray emission the only well-suited method for the analyses of metalpoint drawings. In some primary work, about 25 German and Flemish metalpoint drawings were investigated using spatially resolved SR-XRF analysis at the BAMline at BESSY. This study enlarges the existing FrenchGerman database of metalpoint drawings dating from the 15th and 16th centuries, as these Rembrandt drawings originate from the 17th century where this graphical technique was even rarer and already obsolete. It also illustrates how SR-XRF analysis can reinforce art historical assumptions on the dating of drawings and their connection.
In activation analysis of traces in small samples, the non-equivalence of the activating radiation doses of sample and calibration material gives rise to sometimes tolerable systematic errors. Conversely, analysis of major components usually demands high trueness and precision. To meet this, beam geometry activation analysis (BEAMGAA) procedures have been developed for instrumental photon (IPAA) and neutron activation analysis (INAA) in which the activating neutron/photon beam exhibits broad, flat-topped characteristics. This results in a very low lateral activating flux gradient compared to known radiation facilities, however, at significantly lower flux density. The axial flux gradient can be accounted for by a monitor-sample-monitor assembly. As a first approach, major components were determined in high purity substances as well as selenium in a cattle fodder additive.
Spatially resolved X-ray fluorescence analysis using synchrotron radiation (SR-XRF) at the wavelength shifter beamline, BAMline, at BESSY was used to investigate Renaissance silverpoint drawings as it is extremely sensitive, non-destructive and can be carried out in air using an excitation spot in the hundred micrometer range.
This paper deals with first results of the study of silverpoint drawings of Albrecht Dürer (14711528) belonging to the sketchbook that Albrecht Dürer used during a travel to the Netherlands in 1520/21. These results are compared to a PIXE study performed on drawings from the same sketchbook.
The minor element composition of the silverpoint used for the drawings in the sketchbook was (10.6 ± 3.5) wt.% of Cu and traces of Zn. Mercury was found in the marks but does not belong to the initial composition of the silverpoint as it is attributed to an alteration phenomenon. One drawing of the sketchbook represents an exception. It consists of silver marks containing an additional minor element, Zn, in the marks and was, therefore, created with another silverpoint, probably at a different time than the other drawings.