Filtern
Dokumenttyp
Sprache
- Englisch (19) (entfernen)
Schlagworte
- RFA (5)
- Röntgenfluoreszenzanalyse (5)
- XRF (5)
- Silberstiftzeichnung (4)
- Silverpoint drawing (4)
- X-ray spectrometry (4)
- Albrecht Dürer (3)
- Drawing (2)
- Synchrotron (2)
- Archaeometry (1)
- Archäometrie (1)
- Areal density (1)
- Certified reference material (1)
- Drawings (1)
- Gold (1)
- ICP-IDMS (1)
- INAA (1)
- Isotope ratio (1)
- Jan van Eyck (1)
- Metal point (1)
- Nuclear industry (1)
- Nuclear medicine (1)
- RBS (1)
- Renaissance (1)
- SR-XRF analysis (1)
- SY-XRF (1)
- Silverpoint (1)
- Surface analysis (1)
- Sy-XRF analysis (1)
- XRF analysis (1)
- Zeichnungen (1)
- gold (1)
This Report describes the certification of the reference material antimony implanted in Si/SiO2 intended to be used for calibration of surface and near surface analytical methods. It describes the preparation, homogeneity measurements and the analytical work performed for the certification of both Areal density of antimony Atoms (retained dose) and the isotope amount Ratio as well as giving considerations on the stability of the material.
Spatially resolved X-ray fluorescence analysis using synchrotron radiation (SR-XRF) at the wavelength shifter beamline, BAMline, at BESSY was used to investigate Renaissance silverpoint drawings as it is extremely sensitive, non-destructive and can be carried out in air using an excitation spot in the hundred micrometer range.
This paper deals with first results of the study of silverpoint drawings of Albrecht Dürer (14711528) belonging to the sketchbook that Albrecht Dürer used during a travel to the Netherlands in 1520/21. These results are compared to a PIXE study performed on drawings from the same sketchbook.
The minor element composition of the silverpoint used for the drawings in the sketchbook was (10.6 ± 3.5) wt.% of Cu and traces of Zn. Mercury was found in the marks but does not belong to the initial composition of the silverpoint as it is attributed to an alteration phenomenon. One drawing of the sketchbook represents an exception. It consists of silver marks containing an additional minor element, Zn, in the marks and was, therefore, created with another silverpoint, probably at a different time than the other drawings.
A new setup for fast spatially resolved measurements of elemental trace amounts under total reflection conditions using a new colour X-ray camera is described. Samples prepared on conventional total reflection X-ray fluorescence (TXRF) reflectors were measured at BESSY II synchrotron. A spatial resolution of 50 × 50 µm² was obtained, while the required time for the investigation of a 10 × 10 mm² sample is 30 seconds. The set-up is up to 350 times faster than conventional X-ray fluorescence systems for elemental traces. The major components of the X-ray camera are polycapillary optics and a pn-CCD chip with an active area of 13 × 13 mm². This area is divided into 264 × 264 pixels of 48 × 48 µm². A full X-ray spectrum with a resolution of 152 eV @ 5.9 keV and a chip temperature of 246 K is recorded for each pixel. The chip has a read-out rate of 400 Hz.
A layer of Sb atoms, implanted with an energy of 400 keV and a nominal dose of 5×1016 atoms/cm2 into a high purity silicon wafer, was certified for its areal density (atoms/cm2) using Rutherford backscattering spectrometry (RBS), instrumental neutron activation analysis (INAA) and inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) and for its isotope ratio using INAA and ICP-IDMS. Excellent agreement between the results of the different independent methods was found. In the present work, the measurements of the homogeneity of the areal density of Sb, previously determined with RBS in spots having 1 mm diameter, are improved with synchrotron X-ray fluorescence analysis: Higher precision in even smaller sample spots allows to estimate a reduced inhomogeneity of the whole batch of samples of the order of only 0.4%. Thus the uncertainty of the certified value can further be reduced. Down to fractions of a chip with 0.3×0.4 mm2 area, the areal density is now certified as (4.81±0.06)×1016 Sb atoms/cm2, where the expanded uncertainty 0.06 (coverage factor k=2) corresponds to only 1.2%. The relative merits of the different analytical methods are discussed.