Virtual CT with aRTist
(2021)
Simulation becomes more and more important in modern CT imaging. It is increasingly used to optimize techniques for complex applications, to support the preparation of written procedures, and for educational purposes. The radiographic simulator aRTist is a modelling tool which simulates X-ray imaging using a hybrid analytical and Monte Carlo method to efficiently model the radiation transport. In addition to the relevant physical effects such as absorption, scattering and fluorescence, simplified fast models are employed to describe the characteristics of the X-ray source and the detector. aRTist is well equipped to model realistic X-ray imaging setups due to the ability to load exported CAD object descriptions. A simple CT scan module is contained in aRTist which allows the simulation of standard (circular cone beam) scanning trajectories.
This training session starts with a general introduction to aRTist and will highlight its basic usage. Furthermore, the focus is on the configuration of scan trajectories and batch simulations for virtual CT. The aim is to enable the audience to use the aRTist software for their own experiments in virtual CT.
AdvanCT Virtual CT
(2021)
Simulation becomes more and more important in modern CT imaging. It is increasingly used to optimize techniques for complex applications, and for educational purposes. Simulation can also be used for uncertainty estimation of dimensional CT measurements. The radiographic simulator aRTist is a modelling tool which simulates X-ray imaging using a hybrid analytical and Monte-Carlo method to efficiently model the radiation transport. In addition to the relevant physical effects such as absorption and scattering, simplified fast models are employed to describe the characteristics of the X-ray source and the detector. aRTist is well equipped to model realistic X-ray imaging setups due to the ability to load exported CAD object descriptions. By repetitive simulation runs aRTist can function as virtual CT device. A simple CT scan module is contained in aRTist which allows the simulation of standard (circular cone beam) scanning trajectories.
AdvanCT is a module for aRTist which allows to set up more complex scanning trajectories by attaching geometrical modification functions to the objects in the radiographic scene. In this way, advanced scanning modes can be realized. In addition to deterministic motion, also random variations can be introduced. By combining random variations with deterministic motion, non-ideal (realistic) CT scan geometries can be simulated, e.g. focal spot drift and mechanical instability of the axis of rotation. The AdvanCT module conveniently allows to construct these scenarios in a graphical interface and provides a preview before starting the (potentially long running) batch job. Therefore, deviations from ideal CT scan trajectories can be easily adjusted which is a necessary step towards uncertainty determination from simulation.