Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (19)
- Vortrag (8)
- Beitrag zu einem Tagungsband (4)
- Posterpräsentation (3)
Schlagworte
- Fluorescence (16)
- Microfluidics (9)
- Smartphone (6)
- Fluoreszenz (4)
- MIP (4)
- Mikrofluidik (4)
- Rapid test (3)
- Test strip (3)
- Adulteration (2)
- Air quality (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (25)
- 1.9 Chemische und optische Sensorik (25)
- 8 Zerstörungsfreie Prüfung (6)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (6)
- 1.8 Umweltanalytik (3)
- 4 Material und Umwelt (2)
- 4.0 Abteilungsleitung und andere (2)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- MP Mitglied des Präsidiums (1)
- PST Präsidiale Stabsstelle (1)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (8)
Currently, the development of portable devices to detect traces of chemical species by real time monitoring is a highly topical research area in the chemical sciences. Indeed, the lowering of standards for pollutants in drinking water requires the development of new technologies and devices. In this context, gated sensory nanoparticle systems for selective and sensitive recognition of targets such as heavy metal ions, small molecules or oligonucleotides are excellent candidates[1,2]. Provided that such sensory delivery systems are highly porous nanoparticles loaded with indicator dyes and capped with bulky stoppers that can be uncapped only by the designated analyte, an integration with a microfluidic tubing system designed for droplet-assisted liquid-liquid extraction enable separation of released from still particle-confined dye by phase-transfer extraction and subsequent selective detection by fluorescence. The incorporation in a simple microfluidic tubing system is an innovative way towards the realization of a sensor for trace analysis of target molecules in real time.
Because of the globally increasing prevalence of diabetes, the need for accurate, efficient and at best miniaturized automated analytical systems for sugar detection is still urgent. The development of molecular probes for sugar based on boronic acid receptors1 offers an excellent alternative to the kinetically slow enzyme-based sugar sensors. Moreover, by coupling such chelating units with rhodamines, fluorescein or BODIPY moieties, colorimetric and/or highly fluorescent sugar sensing schemes can be obtained.2 In this work, a boronic acid-functionalized BODIPY probe is described; it binds selectivity to fructose's adjacent diols to form cyclic boronate esters in partially aqueous solutions, with a broad pH range compatibility and a sensitivity in the micromolar range. To enhance the applicability of the fluorometric test in the sense described above, integration with a microfluidic sensor was achieved. The miniaturization of chemical analysis systems yields many functional and economical benefits such as low cost, ease of use, high stability and good portability. With similar selectivity and sensitivity, fructose was detected by fluorescence in real time in the chip, and an assay for the straightforward detection of sugar in sodas was achieved.
A novel synthetic strategy toward highly fluorinated BODIPY dyes with exceptional photostabilities relying on sustainable gold catalysis has been developed. A key to the tailored pyrrole precursors is the gold catalysis performed in ionic liquids as the reaction medium, allowing a facile recycling of the catalysts. The dyes prepared are well-matching with the spectral windows of popular rhodamine dyes and possess high brightness while showing a distinctly higher photostability than the rhodamines especially in aprotic solvents.
A droplet-based microfluidic sensor was developed for the detection of Hg2+ traces in water. The approach uses gated mesoporous nanoparticles loaded with a fluorescent BODIPY dye. The squaraine-based gating mechanism is highly selective for Hg2+ and the indicator release mechanism ensures sensitive detection. The microfluidic system is modular and was assembled from simple PTFE/PFA tubes, while detection was realized with standard optomechanic, optic, and electronic parts. The sensor shows a stable response without memory effects and allows the detection of Hg2+ in water down to 20 ppt.
The fluorescence properties of three molecular rotors, related to 4-dimethylamino-4-nitrostilbene (4-DNS), are studied versus different diesel/kerosene blends. In nonviscous solvents, these compounds can populate a twisted intramolecular charge transfer state which deactivates nonradiatively, successfully suppressing fluorescence emission. Solution experiments with diesel/kerosene blends showed a good linear correlation between the fluorescence intensity of the probe molecules and the diesel fraction of the blend. The dyes have been immobilized on paper, retaining their fluorescence behavior, i.e., negligible emission in the presence of nonviscous organic solvents and increasing fluorescence when the environment is increasingly viscous. When the impregnated paper is devised as a test strip, the latter is compatible with a newly designed smartphone reader system, which allows in-the-field measurements. The method can safely detect the presence of kerosene in diesel at ≥7%, which competes favorably with current standard methods for the detection of diesel adulteration.
Fluorescent sensory MIP (molecularly imprinted polymer) particles were combined with a droplet-based 3D microfluidic system for the sensitive and selective determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in water samples. 2,4-D being an important and widely used herbicide to regulate plant growth, its extensive use leads to food or ground water contamination. Analytical assays based on MIP have emerged as a valuable tool in the field of environmental analysis thanks to low production costs, stability, format adaptability and their ability to recognize a wide variety of targets, such as the critical neutral organic molecules present in water: herbicides, pesticides, antibiotics, etc.
To accomplish this, a tailor-made fluorescent indicator cross-linker was designed that translates directly the binding event into an enhanced fluorescence signal. This phenoxazinone-type cross-linker was co-polymerized into a thin MIP layer grafted from the surface of silica microparticles. The latter was achieved by integration of the fluorescent core-shell MIP sensor particles into a modular microfluidic platform that allows for an in-line phase-transfer assay, extracting the analyte from aqueous sample droplets into organic phase droplets that contain the sensor particles.
This tool offering a novel simple and rapid way for the detection of herbicides, real-time fluorescence determination of 2,4-D down to 20 nM was realized with the system and applied for the analysis of worlwide surface water samples.
The identification and quantification of phosphorylated amino acids, peptides and proteins is one of the key challenges in contemporary bioanalytical research, noteworthy to diagnose and treat diseases at an early stage. Small sensing devices like microfluidic chips combined with “smart” detection chemistry and simple data assessment, processing and presentation are attractive in this regard. We developed novel synthetic probes, targeting phosphorylated amino acids, based on core-shell microparticles consisting of a silica core coated with a molecularly imprinted polymer shell (MIP). These “plastic antibodies” which are extremely robust, resist denaturing solvents and high temperatures, can be reproducibly produced at low cost, can potentially overcome many of the problems in the current detection strategies. The MIP layer, containing a fluorescent probe monomer, responds to phosphorylated amino acids such as phosphorylated tyrosine (pTyr) with a significant imprinting factor, i.e. selectivity, higher than 3.5, and a “lighting-up” of its fluorescence accompanied by the development of a strongly red-shifted emission band. The bead-based ratiometric detection scheme has also been successfully transferred to a microfluidic chip format to demonstrate its applicability to rapid assays. Such a device could yield an automated pTyr measurement system in the future. The setup was built by coupling a PDMS/Teflon/glass microfluidic chip with an optical setup for fluorescence measurements able to extract and monitor pTyr concentration from 0.5–200 μM.
2,4-D ist ein in der Landwirtschaft weitverbreitetes Pflanzenschutzmittel, das Grundwasser kontaminiert, sich innerhalb der Nahrungskette anreichert und Umwelt- und Gesundheitsprobleme verursachen kann. Hier stellen die Autoren ein mikrofluidisches Nachweissystem für die Echtzeitdetektion von 2,4-D in Grund- oder Oberflächenwasser vor. Es basiert auf der Kombination 2,4-D-selektiver, fluoreszierender, molekular geprägter Polymer-(MIP-)Mikropartikel mit einem 3D-mikrofluidischen Extraktions- und Detektionssystem. Messungen vor Ort sollen damit künftig möglich sein.