Filtern
Dokumenttyp
- Vortrag (8) (entfernen)
Referierte Publikation
- nein (8)
Schlagworte
- Fluorescence (4)
- Microfluidics (4)
- MIP (3)
- Mikrofluidik (2)
- Amino acids (1)
- Chlor (1)
- Chlorine (1)
- Fluoreszenz (1)
- Fluorezsenz (1)
- Microbial (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (8)
Microbial contamination of fuels by fungi or bacteria poses risks such as corrosion and fuel system fouling, which can lead to critical problems in refineries and distribution systems and has a significant economic impact at every stage of the process. Many factors have been cited as being responsible for microbial growth, like the presence of water in the storage tanks. In fact, only 1 % water in a storage system is sufficient for the growth of microorganisms like bacteria or yeasts, as well as for the development of fungal biomass at the oil/water interface.
This work presents a rapid test for the accurate determination of genomic DNA from aqueous fuel extracts. The detection is based on the use of polystyrene-mesoporous silica core-shell particles onto which modified fluorescent molecular beacons are covalently grafted. These beacons contain in the hairpin loop a target sequence highly conserved in all bacteria, corresponding to a fragment of the 16S ribosomal RNA subunit. The designed single-stranded molecular beacon contained fluorescein as an internal indicator and a quencher in its proximity when not hybridized. Upon hybridization in presence of the target sequence, the indicator and the quencher are spatially separated, resulting in fluorescence enhancement. To perform the assay the developed particles were deposited on different glass fibre strips to obtain a portable and sensitive rapid test. The assays showed that the presence of genomic DNA extracts from bacteria down to 50–70 μg L–1 induced a fluorescence response. The optical read-out was adapted for on-site monitoring by fitting a 3D-printed case to a conventional smartphone, taking advantages of the sensitivity of the CMOS detector. Such embedded assembly enabled the detection of genomic DNA in aqueous extracts down to the mg L–1 range and represents an interesting step toward on-site monitoring of fuel contamination.
Per- and polyfluoroalkyl substances (PFAS) are a class of man-made organo-fluorine chemicals that have become environmental contaminants of emerging concern, originating from a variety of materials such as adhesive, stain- and oil-resistant coatings, firefighting foams, etc. The high strength of this C-F bond makes PFAS thermodynamically stable and resistant to (bio)degradation, thus retaining them in the environment over time. Perfluoroalkyl carboxylic acids (PFCAs), one category of the most used PFAS, consist of a fully fluorinated carbon backbone and a charged carboxylic acid headgroup, and have been classified as Substances of Very High Concern (SVHC) and added to the REACH Candidate List due to their persistence in the environment, non-biodegradability and toxicological effects.[1-2] Traditional techniques for the analysis of PFCAs include GC-MS, HRMS and HPLC-based approaches, which are laborious, not portable, costly and require trained personnel. In contrast, fluorescence assays can be designed as easy-to-operate, portable and cost-effective methods with high sensitivity and fast response. Integration of fluorescent probes with an adequately miniaturized assay enables a promising alternative for PFCAs analysis.
Here, a novel guanidine fluorescent probe has been synthesized and fully characterized for the detection of PFCAs in a biphasic extract-&-detect assay. The fluorescent probe was then incorporated into polymeric matrices supported by a red dye-doped SiO2 nanoparticle to construct a dual-emission sensing platform. Such a system allows precise and selective detection of PFCAs, reducing the interference of competitors, matrix effects and other factors except for the PFCAs. The system was then employed in a droplet-based microfluidic setup which offers a portable and easy to operate detection platform.
Chlorination of pool water and wastewater, in food and pharmaceutical production, as well as in pesticide and paper manufacturing is a routinely used technique. However, the amount of chlorine in water must be strictly adjusted, to ensure enough concentration to kill pathogenic bacteria and viruses, while preventing too high concentrations inducing negative effects on human health. As an indicator, a molecular fluorescent probe based on a BODIPY structure was designed. This indicator exhibits a sensitive and selective fluorescence response upon increasing concentrations of hypochlorite in aqueous solvent mixtures. Real-time analyses became possible after the integration of this fluorescent indicator into newly designed 2D & 3D microfluidic chips incorporating a passive sinusoidal mixer and a micro-hydrocyclone, respectively. A comparison of the two microfluidic systems, including their ability to prevent accumulation or circulation of microbubbles, has shown excellent fluidic behaviour for the micro-hydrocyclone device. This system was distinctly more robust against gas bubbles, showed a higher signal gain and allowed to halve the limit of detection to 0.02 mg L–1. The use of the 3D system to quantify the chlorine content of pool water samples for sensitive and quantitative chlorine monitoring has been demonstrated.
Fluorescent sensory MIP (molecularly imprinted polymer) particles were combined with a droplet-based 3D microfluidic system for the sensitive and selective determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in water samples. 2,4-D being an important and widely used herbicide to regulate plant growth, its extensive use leads to food or ground water contamination. Analytical assays based on MIP have emerged as a valuable tool in the field of environmental analysis thanks to low production costs, stability, format adaptability and their ability to recognize a wide variety of targets, such as the critical neutral organic molecules present in water: herbicides, pesticides, antibiotics, etc.
To accomplish this, a tailor-made fluorescent indicator cross-linker was designed that translates directly the binding event into an enhanced fluorescence signal. This phenoxazinone-type cross-linker was co-polymerized into a thin MIP layer grafted from the surface of silica microparticles. The latter was achieved by integration of the fluorescent core-shell MIP sensor particles into a modular microfluidic platform that allows for an in-line phase-transfer assay, extracting the analyte from aqueous sample droplets into organic phase droplets that contain the sensor particles.
This tool offering a novel simple and rapid way for the detection of herbicides, real-time fluorescence determination of 2,4-D down to 20 nM was realized with the system and applied for the analysis of worlwide surface water samples.
Currently, the development of portable devices to detect traces of chemical species by real time monitoring is a highly topical research area in the chemical sciences. Indeed, the lowering of standards for pollutants in drinking water requires the development of new technologies and devices. In this context, gated sensory nanoparticle systems for selective and sensitive recognition of targets such as heavy metal ions, small molecules or oligonucleotides are excellent candidates[1,2]. Provided that such sensory delivery systems are highly porous nanoparticles loaded with indicator dyes and capped with bulky stoppers that can be uncapped only by the designated analyte, an integration with a microfluidic tubing system designed for droplet-assisted liquid-liquid extraction enable separation of released from still particle-confined dye by phase-transfer extraction and subsequent selective detection by fluorescence. The incorporation in a simple microfluidic tubing system is an innovative way towards the realization of a sensor for trace analysis of target molecules in real time.
The identification and quantification of phosphorylated amino acids, peptides and proteins is one of the key challenges in contemporary bioanalytical research, noteworthy to diagnose and treat diseases at an early stage. Small sensing devices like microfluidic chips combined with “smart” detection chemistry and simple data assessment, processing and presentation are attractive in this regard. We developed novel synthetic probes, targeting phosphorylated amino acids, based on core-shell microparticles consisting of a silica core coated with a molecularly imprinted polymer shell (MIP). These “plastic antibodies” which are extremely robust, resist denaturing solvents and high temperatures, can be reproducibly produced at low cost, can potentially overcome many of the problems in the current detection strategies. The MIP layer, containing a fluorescent probe monomer, responds to phosphorylated amino acids such as phosphorylated tyrosine (pTyr) with a significant imprinting factor, i.e. selectivity, higher than 3.5, and a “lighting-up” of its fluorescence accompanied by the development of a strongly red-shifted emission band. The bead-based ratiometric detection scheme has also been successfully transferred to a microfluidic chip format to demonstrate its applicability to rapid assays. Such a device could yield an automated pTyr measurement system in the future. The setup was built by coupling a PDMS/Teflon/glass microfluidic chip with an optical setup for fluorescence measurements able to extract and monitor pTyr concentration from 0.5–200 μM.