Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (33)
- Vortrag (28)
- Posterpräsentation (15)
- Zeitschriftenartikel (11)
- Beitrag zu einem Sammelband (10)
- Sonstiges (3)
Schlagworte
- Computed radiography (4)
- THz radiation (4)
- Absorption (3)
- Dielectric materials (3)
- Digital radiography (3)
- Far-infrared spectroscopy (3)
- Image quality (3)
- Image reconstruction (3)
- Polymers (3)
- SAFT (3)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (28)
The standard for advanced technical ceramics ENV 843-4 of 1995 (Vickers, Knoop and Rockwell superficial hardness tests) was validated within the framework of the CERANORM EC-project. The paper reports on depth sensing hardness measurements done for comparison with the other hardness tests. The instrumented indentation test is a modern technique (recent issue ISO/DIS 14577) that has the potential to take into account the specific response of materials in a much better way. An evaluation has been made to establish whether the instrumented hardness technique is a appropriate method for advanced technical ceramics and offers potential for additional applications.
Radiography is a helpful method to identify the inherent structure of unexploded ordnances (UXOs). Portable Computed Radiography (CR) systems on the basis of phosphor imaging plates , have attracted attention for NDT-applications during the last few years. A portable IP system ACR 2000 has been tested for X-ray inspection of UXO's in the field. Digitised radiographs are presented to explain the needs and demands for a reliable characterisation of UXO's. Computed radiographs of UXOs are compared with film radiographs exposed in the same way, to evaluate the reliability and to identify advantages and disadvantages of the CR system for UXO inspection. Film based and CR systems provide sufficient information for identification of chemical warfare agents in UXO's, which is an essential problem for explosive ordnance disposal. The advantages and the potential of the portable CR system is discussed on the basis of experiences gathered during different field trails.
Für die Berücksichtigung mechanischer Belastungen unterhalb der Streckgrenze ist im Rahmen einer zuverlässigen Bauteilauslegung die Kenntnis der elastischen Konstanten von besonderer Bedeutung. Für die experimentelle Bestimmung des Elastizitätsmoduls wurde eine Vielzahl von Verfahren entwickelt, die zum Teil werkstoffspezifisch Eingang in die Normung gefunden haben. Prinzipiell können diese Verfahren in zwei Gruppen unterteilt werden; die statischen und die dynamischen Prüfverfahren. Die statischen Verfahren beruhen auf der direkten Messung des Spannungs-Dehnungs-Zusammenhangs während einer mechanischen Belastung im elastischen Verformungsbereich (Zug, Biegung, Druck). Die dynamischen Verfahren basieren auf der Schwingungsanregung eines Prüfkörpers und der Analyse der resultierenden Schwingungen (Resonanzmethode oder Impulsanregungsmethode) oder auf der Messung der Ultraschallausbreitungsgeschwindigkeit. Stellvertretend für die dynamischen Verfahren wird im ersten Teil dieses Beitrages die Resonanzmethode vorgestellt. Der zweite Teil dieses Beitrages fasst die werkstoffabhängigen Ergebnisse der E-Modulbestimmung mit statischen Verfahren im Zug- und Biegeversuch zusammen.
Imaging Capability of Terahertz and Millimeter-Wave Instrumentations for NDT of Polymer Materials
(2006)
Imaging capability of terahertz and milimeter-wave instrumentations for NDT of polymer materials
(2006)
Computed THz - tomography
(2012)
Available THz Time Domain Spectroscopy (THz-TDS) systems can be applied in a pulse echo mode for
tomographic application. In contrast to common transmission methods, a TDS reflection geometry was used to
inspect cylindrical polyethylene samples with internal voids of known shape. The geometry of the voids was
simulated and its shape was reconstructed. B-scan pulse echo images were acquired in the time domain, similar
to UT pulse echo techniques on basis of the numeric model. The results were used to verify the simulation model
and the reconstruction algorithm, based on a modified Synthetic Aperture Focusing Technique (SAFT). The
model was used to conclude recommendations on an optimized measurement setup in the reflection mode. Based
on that, the quality of the reconstructed tomograms was improved.
In der Filmradiografie kann durch den Einsatz von Metallfolien und Metallfolienkombinationen der Bildkontrast verbessert werden. Die Mechanismen zur Erzeugung der latenten Röntgenbilder und deren Sichtbarmachung für das menschliche Auge sind in Speicherfolien nicht mit denen in einem Röntgenfilm identisch. Demzufolge lassen sich die in den Normen zur Filmradiografie veröffentlichten Empfehlungen zum Einsatz von Metallfolien und zur Auswahl der Röhrenspannung nicht unmittelbar auf die Computer-Radiografie zur Schweißnahtprüfung übertragen. Die Qualität digitaler Röntgenbilder wird von der Bildunschärfe und dem Kontrast-zu-Rausch-Verhältnis (CNR) bestimmt. Während die Norm EN 14784-1 handhabbare Verfahren zur Bestimmung der inneren Unschärfe und des Signal-zu-Rausch-Verhältnisses (SNR) beschreibt, sind die in EN 14784-2 vorgegebenen Vorgehensweisen zur Kontrastverbesserung durch die Vorgaben zur geeigneten Röhrenspannung und Metallfoliendicke für die Schweißnahtprüfung nicht ausreichend dargelegt. Um die Parameter zur Verbesserung der Bildqualität von CR-Systemen für den Fall der radiografischen Durchstrahlungsprüfung von Schweißnähten zu optimieren, wurden systematische Untersuchungen zum Einfluss eines Kupfer-Vorfilters, von Bleifolien-Speicherfolien-Kombinationen und der Röhrenspannung auf den Bildkontrast von Stahlstufenaufnahmen durchgeführt. Auf der Grundlage dieser Ergebnisse wurden Empfehlungen zum Einsatz der Metallfilter und -folienkombinationen sowie zur Auswahl geeigneter Röhrengrenzspannungen für die Speicherfolientechnik zur Optimierung der Durchstrahlungsprüfung von Schweißnähten abgeleitet.