Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (76) (entfernen)
Schlagworte
- Interlaboratory comparison (8)
- Gas chromatography (6)
- Extraction (5)
- Analysis (4)
- Brominated flame retardant (4)
- Groundwater (4)
- HPLC-MS/MS (4)
- Boden (3)
- Breath (3)
- Chiral separation (3)
- Mass spectrometry (3)
- Microplastics (3)
- Proficiency testing (3)
- VOC (3)
- Volatile organic compounds (3)
- Volatilome (3)
- A549 (2)
- Alcohol marker (2)
- Aniline (2)
- Certification (2)
- Certified reference materials (2)
- Chloroanilines (2)
- Degradation (2)
- Diastereomers (2)
- Ethyl glucuronide (2)
- Flame retardant (2)
- Fortification (2)
- GC-FID (2)
- GC-MS (2)
- HBCD (2)
- Hydroxylation (2)
- Kinetics (2)
- Liquid chromatography (2)
- Long term stability (2)
- Lung cancer (2)
- Methylanilines (2)
- Micropulverization (2)
- Mikroplastik (2)
- Organic pollutants (2)
- Phenols (2)
- Reference materials (2)
- Sampling (2)
- Sewage sludge (2)
- Soil (2)
- Solid phase microextraction (2)
- Summation parameter (2)
- AOX (1)
- APCI (1)
- Absolute configuration (1)
- Acrylamid (1)
- Active sampling (1)
- Adsorption (1)
- Analysis and identification (1)
- Anomalous dispersion (1)
- Anomeric configuration (1)
- Antioxidant properties (1)
- Arrhenius model (1)
- Artificial weathering (1)
- BFR (1)
- BPA (1)
- BTEX (1)
- Bacteria (1)
- Benzenes (1)
- Beta-cyclodextrin (1)
- Binding affinity (1)
- Bio test battery (1)
- Bioaccumulation (1)
- Biochar (1)
- Biofouling (1)
- Bioisomerization (1)
- Biomarkers (1)
- Bleaching (1)
- Bromierte Falmmschutzmittel (1)
- Brominated flame retardants (1)
- CEC-L-103 (1)
- CRM (1)
- Calibration (1)
- Calix[4]resorcinarenes (1)
- Cancer (1)
- Chemometrics (1)
- Collaborative trial (1)
- Combustion (1)
- Conformational chirality (1)
- Contaminated site (1)
- Contamination (1)
- Crosslinking (1)
- Crystal structure (1)
- Crystal structures (1)
- Cysteic acid (1)
- Cytochrom (1)
- Cytochrome P450 (1)
- Cytochromes (1)
- D-Glucuronic acid derivates (1)
- DEHP (1)
- DFA (1)
- Data-to-parameter ratio = 20.4 (1)
- Degradation of refrigerants (1)
- Derivatisation (1)
- Derivatisierung (1)
- Derivatization (1)
- Detection dog (1)
- ERM (1)
- Einfluß (1)
- Eingnugsprüfung (1)
- Elution order (1)
- Enantiomer fraction (1)
- Enantiomer-specific bioaccumulation (1)
- Enantiomer-specific determination (1)
- Enantiomeric fraction (1)
- Enantiomers (1)
- Equivalence (1)
- Equivalent carbon number (1)
- European Reference Material (1)
- European reference material (1)
- European waste list (1)
- External quality management (1)
- FTIR imaging (1)
- Fish feeding experiment (1)
- Flame ionization detection (1)
- Flame retardants (1)
- Flammschutzmittel (1)
- Fluoroacetic acid (1)
- Food (1)
- Fuel (1)
- Fungi (1)
- Furfurals (1)
- GC-AED (1)
- GC/MS (1)
- GC/MS-MS (1)
- GCMS (1)
- Gaschromatographie (1)
- Gasoline (1)
- Ground water (1)
- Groundwater monitoring (1)
- HBCDs (1)
- HPLC (1)
- HPLC-DAD (1)
- HPLC-ESI-MS/MS (1)
- HPLCMS/MS (1)
- Hair (1)
- Hair testing (1)
- Hexabromcyclododecan (1)
- High resolution NMR (1)
- High-throughput analysis (1)
- Homogeneity (1)
- Honey bees (1)
- Hydrocarbons (1)
- Hydrochar (1)
- Hydrogen bonded molecular capsule (1)
- ICP-MS (1)
- ICP-OES (1)
- IR spectrometry (1)
- Indoor air (1)
- Intercomparison (1)
- Interlaboratory study (1)
- International intercomparison (1)
- Ion chromatography (1)
- Isoleucin (1)
- Isomerisation (1)
- LC-MS (1)
- LC/MS-MS (1)
- Lung cancer cell culture (1)
- MOSH/MOAH (1)
- Marker (1)
- Measurement uncertainty (1)
- Metabolism of HBCD (1)
- Metaboliten (1)
- Metal-organic complexes (1)
- Methane (1)
- Method development (1)
- Method validation (1)
- Micropulverized extraction (1)
- Mineral oil hydrocarobons (1)
- Mineralölkohlenwasserstoffe (1)
- Minor isomers (1)
- Moisture (1)
- Molecular dynamics (1)
- Molecular modeling (1)
- Molecular simulation (1)
- Municipal sludge (1)
- NPE (1)
- Nation metrology institutes (1)
- Near Infrared Spectroscopy (1)
- Odour discrimination task (1)
- Optical rotation (1)
- Organohalogen compounds (1)
- Oxidation (1)
- PAH (1)
- PCB (1)
- PLS-DA (1)
- Passive sampling (1)
- Pentachlorophenol (1)
- Pflanzenwachstum (1)
- Phase I metabolism (1)
- Phosphous recovery (1)
- Photometric P determination (1)
- Polybrominated biphenyls (PBBs) (1)
- Polybrominated diphenyl ethers (PBDEs) (1)
- Polycyclic aromatic hydrocarbons (1)
- Polymer (1)
- Polypropylene (1)
- Polystyrene (1)
- Polyurethane (1)
- Polyurethanes (1)
- Predicting sites of metabolism (1)
- Process water (1)
- Proficiency Testing (1)
- Proficiency test (1)
- Pulverization (1)
- Pyrolysis (1)
- QM (1)
- R factor = 0.043 (1)
- Rainwater (1)
- Raman imaging (1)
- Rearrangement (1)
- Reference material (1)
- Reference organisms (1)
- Regulation (1)
- Remediation (1)
- Reproducibility (1)
- Ring test (1)
- Ring test structure (1)
- Ringversuch (1)
- SEC (1)
- SPME (1)
- Sediment (1)
- Shelf life (1)
- Simulation (1)
- Single-crystal X-ray study (1)
- Sniffer dogs (1)
- Society of hair testing (1)
- Software (1)
- Sonication (1)
- Sorption (1)
- Stabilisation (1)
- Stability (1)
- Standardisation (1)
- Standardization (1)
- Static headspace (1)
- Statistical thermodynamics (1)
- Statistics (1)
- Support vector machines (1)
- Suspended organic matter (1)
- Synthesis (1)
- Synthetic air (1)
- T = 273 K (1)
- TBBPA-dbpe (1)
- TED-GC-MS (1)
- TFA (1)
- Thermal degradation (1)
- Thermo-desorption (1)
- Thyroxin (1)
- Total organic carbon (1)
- Total petroleum hydrocarbons (1)
- Trace elements (1)
- Traceability (1)
- Trichloroethene (1)
- Urine (1)
- Vinyl chloride (1)
- Waste (1)
- Waste ecotoxicity (1)
- Waste legislation (1)
- Waste wood (1)
- X-ray (1)
- X-ray analysis (1)
- X-ray structure analyses (1)
- dog training (1)
- herbs (1)
- reference materials, (1)
- scent dog (1)
- smell (1)
- training model (1)
- wR factor = 0.121 (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (18)
- 1.7 Organische Spuren- und Lebensmittelanalytik (18)
- 4 Material und Umwelt (4)
- 6 Materialchemie (4)
- 5 Werkstofftechnik (3)
- 6.3 Strukturanalytik (3)
- 4.3 Schadstofftransfer und Umwelttechnologien (2)
- 5.3 Polymere Verbundwerkstoffe (2)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 1.2 Biophotonik (1)
Paper des Monats
- ja (1)
1,2,5,6,9,10-hexabromocyclododecane (HBCD), a widely used flame retardant, is an ubiquitous contaminant in
the environment. Still, only little is known about the distribution and behavior in the environment such as
bioaccumulation or biotransformation of HBCD stereoisomers. In order to investigate enrichment and possible
bioisomerization of HBCD stereoisomers, Mirror Carps were exposed to pure (+)- and (-)-γ-HBCD, randomly
sampled after a predefined specific period and subjected to enantiomer-specific determination of α-, β-, and γ-
HBCD. No evidence for the isomerization of HBCD stereoisomers was observed in Mirror Carp fillets.
The binding affinities of the six main hexabromocyclododecane (HBCD) stereoisomers and all of their possible 48 allylic pentabromocyclododecene (PBCD) metabolites to the endocrinous human transthyretin receptor (hTTR) were investigated and compared to the natural binder thyroxine, and the two brominated diphenyl ethers BDE-47 and 3-hydroxy-BDE-47. The endocrine disrupting potency was approximated by a combination of two methods: a surface matching with the natural binder thyroxine (T4) followed by approximation of free binding energies for various binding modes within hTTR. The results indicate slightly higher binding affinities for both BDE structures than for T4 itself and similarly high affinities for two trans-configurated PBCD isomers. For many other PBCD isomers, intermediate values were computed, whereas all HBCD diastereomers yielded significantly lower binding affinities.
Der Einsatz aktiver (Pumpprobennahme,
Schöpfprobennahme) und passiver (Diffusionsprobennahme)
Probennahmetechniken zur Gehaltsbestimmung von
LHKW sowie Ethen und Methan in Grundwasser wird aus
ordnungsbehördlicher Sicht hinsichtlich der Vergleichbarkeit
von Analysendaten untersucht. Am Beispiel einer Kontamination
mit Trichlorethen sowie 1,2-Dichlorethen und
Vinylchlorid kann deutlich gemacht werden, dass die Einsatzmöglichkeit
der passiven Probennahme durch unzureichende
Strömungsverhältnisse im Aquifer sowie biologische
Aktivität im Pegelrohr begrenzt ist. Der aktiven Probennahme
ist bei ungeklärten oder unzureichenden Strömungsverhältnissen
im Grundwasserleiter daher der Vorzug
zu geben. Das gaschromatographische Verfahren für Vinylchlorid
mittels Dampfraumtechnik wird um die Quantifizierung
von Methan und Ethen erweitert. Dabei werden für
die Bewertung von Altlasten relevante Bestimmungsgrenzen
von 0,1 µg/l (Vinylchlorid, Ethen) sowie 5 µg/l (Methan)
erreicht.
Aus der Validierung der Analysenmethode und den
Ergebnissen verschiedener Probennahmen werden Toleranzbereiche
für die Ergebnisse eines Grundwassermonitorings
abgeschätzt. Diese Streubreiten von Monitoring-
Ergebnissen sollten von Ingenieurbüros und zuständigen
Ordnungsbehörden bei der Bewertung der komplexen Abbauprozesse
eines LHKW-Grundwasserschadens beachtet
werden.
HBCD stereoisomer pattern in mirror carps following dietary exposure to pure Gamma-HBCD enantiomers
(2010)
An international intercomparison involving eight national metrology institutes (NMIs) was conducted to establish their current measurement capabilities for determining five selected congeners from the brominated flame retardant classes polybrominated diphenyl ethers and polybrominated biphenyls. A candidate reference material consisting of polypropylene fortified with technical mixtures of penta-, octa- and decabromo diphenyl ether and decabromo biphenyl, which was thoroughly assessed for material homogeneity and stability, was used as study material. The analytical procedures applied by the participants differed with regard to sample pre-treatment, extraction, clean-up, employed calibrants and type of calibration procedure as well as regarding analytical methods used for separation, identification and quantification of the flame retardant congeners (gas chromatography coupled to an electron capture detector (GC-ECD), gas chromatography-mass spectrometry in the electron ionisation mode (GC-EI-MS), gas chromatography-mass spectrometry in the electron capture negative ionisation mode (GC-ECNI-MS), and liquid chromatography-inductive coupled plasma-mass spectrometry (LC-ICP-MS)). The laboratory means agreed well with relative standard deviations of the mean of means of 1.9%, 4.8%, 5.5% and 5.4% for brominated diphenyl ether (BDE) 47, 183 and 209 and for the brominated biphenyl (BB) congener 209, respectively. For BDE 206, a relative standard deviation of 28.5% was obtained. For all five congeners, within-laboratory relative standard deviations of six measurements obtained under intermediate precision conditions were between 1% and 10%, and reported expanded measurements uncertainties typically ranged from 4% to 10% (8% to 14% for BDE 206). Furthermore, the results are in good agreement with those obtained in the characterization exercise for determining certified values for the flame retardant congeners in the same material. The results demonstrate the state-of-the-art measurement capabilities of NMIs for quantifying representative BDE congeners and BB 209 in a polymer. The outcome of this intercomparison (pilot study) in conjunction with possible improvements for employing exclusively calibrants with thoroughly assessed purity suggests that a key comparison aiming at underpinning calibration and measurement capability (CMC) claims of NMIs can be conducted.
The resource-saving utilisation of recovered
waste wood is a matter of growing concern. In several
European countries, this utilisation is governed by regulations
and is dependent on the contents of certain trace
elements and organic compounds. Thus, for decisionmaking
with respect to waste wood management (recycling
or combustion), reliable analytical data are needed and, due
to their great economic and environmental impact, must be
assured by appropriate quality control. To support the
improvement in quality assurance in waste wood analysis,
for the first time, a wood reference material was certified
for its mass fractions of arsenic, cadmium, chromium,
copper, lead, mercury, and pentachlorophenol (PCP).
These analytes were selected because they represent typical
constituents of wood preservatives most widely used in the
past. Material preparation and testing of homogeneity and
stability were carried out by BAM Federal Institute for
Materials Research and Testing. The certification measurements
were performed involving selected laboratories
with documented expertise in the field of waste wood
analysis. The certified values and their corresponding
uncertainties were assigned in full compliance with the
requirements of ISO Guide 35. The certified mass fractions
and their expanded uncertainties (k/i> = 2) are as follows:
(3.1 ± 0.5) mg/kg for As, (3.02 ± 0.24) mg/kg for Cd,
(36.4 ± 2.6) mg/kg for Cr, (22.9 ± 1.7) mg/kg for Cu,
(0.60 ± 0.14) mg/kg for Hg, (39 ± 4) mg/kg for Pb, and
(7.9 ± 0.6) mg/kg for PCP. The certified material is
available as European Reference Material ERM®-CD100.
A number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersible pump were about one order of magnitude higher than those obtained from diffusion sampling. The gas chromatographic determination for hydrogen and methane requires manual injection of gas samples and detection by a pulsed discharge detector (PDD) and allows limits of quantification of 3 nM dissolved hydrogen and 1 µg L-1 dissolved methane in groundwater. The combined standard uncertainty of the bubble stripping and GC/PDD quantification of hydrogen in field samples was 7% at 7.8 nM and 18% for 78 nM.
High-performance liquid chromatography tandem mass spectrometry (HPLC–MS/MS) was applied to sterospecifically quantify the content of α-, β-, and γ-hexabromocyclododecane (HBCD) in six fish species from the Norwegian Etnefjorden. A combination of a β-PM cyclodextrin and an achiral column enabled the paired chromatographic separation of the stereoisomers in the order (-)-α-, (+)-α-, (-)-β-, (+)-β-, (+)-γ- and, (-)-γ-HBCD. The limits of detection were in the range of 6–21 pg g-1 depending on the stereoisomer and the concentrations of α-, β-, and γ-HBCD in fillets ranged from <5.4 ng g-1 to 11.1 µg g-1 lipid weight. α-HBCD enantiomers were throughout dominating, and in most cases the accumulation of the respective first eluted enantiomers ((-)-α-, (-)-β- and (+)-γ-HBCD) was observed. Deviations from the racemic EF-value were considered to be significant if it was outside of the expanded uncertainty range for each of the racemic HBCD-ratios. The composition of HBCD isomers varied between the investigated fish species and the relative high values for the γ-HBCD concentrations for the bottom-dwellers flounder and thorny skate seems to echo the HBCD pattern of ocean sediments.
The ecotoxicological characterization of waste is part of its assessment as hazardous or non-hazardous according to the European Waste List. For this classification 15 hazard criteria are derived from the Council Directive 91/689/EEC on hazardous waste. Some of the hazard criteria are based on the content of dangerous substances. The criterion H14 'ecotoxic' lacks of an assessment and testing strategy and no specific threshold values have been defined so far. Based on the recommendations of CEN guideline 14735 (2005), an international round robin test (ring test) was organized by the German Federal Environment Agency in order to define suitable test methods for the biological assessment of waste and waste eluates. A basic test battery, consisting of three aquatic and three terrestrial tests, was compiled. In addition, data were submitted for ten additional tests (five aquatic (including a genotoxicity test) and five terrestrial ones). The tests were performed with three representative waste types: an ash from an incineration plant, a soil containing high concentrations of organic contaminants (polycyclic aromatic hydrocarbons) and a preserved wood waste. The results of this ring test confirm that a combination of a battery of biological tests and chemical residual analysis is needed for an ecotoxicological characterization of wastes. With small modifications the basic test battery is considered to be well suitable for the hazard and risk assessment of wastes and waste eluates. All results and documents are accessible via a web-based data bank application.
Hexabromocyclododecane enantiomers: microsomal degradation and patterns of hydroxylated metabolites
(2011)
The degradation of the enantiomers of α-, β-, and γ-hexabromocyclododecane (HBCD) by phase I metabolism was investigated using induced rat liver microsomes. HBCD isomers were quantified using HPLC-MS/MS (ESI-) after separation on a combination of a reversed phase and a chiral analytical column. The degradation of all six isomers followed first-order kinetics and the estimated half-lives ranged from 6.3 min for both β-HBCD enantiomers to 32.3 min in case of (+)-γ-HBCD. (+)-α- and (–)-γ-HBCD displayed significantly shorter half-lives than their corresponding antipodes. It could be shown that this degradation led to a significant enrichment of the first eluting enantiomers (–)-α- and (+)-γ-HBCD. Individual patterns of mono- and dihydroxylated derivatives obtained from each α- and γ-HBCD enantiomer were seen to be distinctly characteristic. The patterns of monohydroxylated HBCD derivatives detected in liver and muscle tissues of pollack, mackerel and in herring gull eggs were largely similar to those observed in the in vitro experiments with rat liver microsomes. This enabled individual hydroxy-HBCDs to be assigned to their respective parent HBCD enantiomers.
Levels of α-, β-, and γ-hexabromocyclododecane (HBCD) were determined in pooled eggs from herring gulls (Larus argentatus) sampled on three bird sanctuaries near the German North Sea coast between 1988 and 2008 (Mellum and Trischen) and the German Baltic Sea coast between 1998 and 2008 (Heuwiese) and archived by the German Environmental Specimen Bank. Pressurized fluid extraction, gel permeation chromatography, and LCMS/MS using 13C12-labelled isotope standards and a chiral column were applied. α-HBCD was the dominating diastereomer and ranged between 3.7 and 107 ng g-1 lw while β- and γ-HBCD were throughout close to LOQ. The highest α-HBCD concentration was found in eggs from Mellum sampled in the year 2000. Interestingly, HBCD in eggs from the three islands displayed similar time courses with levels increasing to a peak contamination around 2000 and decreasing levels ever since. Chiral signatures of α-HBCD in eggs differed among the islands but indicated a preferential enrichment of the first eluting enantiomer (-)-α-HBCD.
Technical 1,2,5,6,9,10-hexabromocyclododecane (HBCD) consists largely of three diastereomers (α-, β-, and γ-HBCD) produced by the trans addition of bromine to cis,trans,trans-cyclododeca-1,5,9-triene (CDT). However, another seven diastereomers are theoretically possible and may be produced by trans addition of bromine across the double bonds of the other three isomers of 1,5,9-CDT. There are indications that small amounts of the minor HBCD isomers may be present in commercial HBCD mixtures or in products containing this brominated flame retardant (BFR). Such minor components may indeed derive from traces of other 1,5,9-CDTs in the cis, trans, trans starting material, however their formation may also be possible through isomerizations during the processing of this BFR or by bioisomerization subsequent to its release into the environment. Two of the seven additional diastereomers (δ- and ε-HBCD) were synthesized previously from trans,trans,trans-CDT. We now report the preparation of the remaining five diastereomers, ζ-, η-, and θ-HBCD from cis,cis,trans-CDT and ι- and κ-HBCD from cis,cis,cis-CDT, and their characterization by 1H NMR spectroscopy and X-ray crystallography. The availability of these further diastereomers of HBCD should aid in determining if the minor isomers are present in commercial samples of this BFR, in products containing HBCDs, or in environmental samples. We have also carried out an X-ray crystal structure determination on ε-HBCD, so that crystal structures are now available for all 10 HBCD diastereomers.
A novel approach for the simulation of host.guest systems by systematically scanning the host moleculefs orientations within the guest cavity is presented along with a thermodynamic strategy for determining preferential binding modes and corresponding optimal interaction energies between host and guest molecules. By way of example, the elution order of hexabromocyclododecane stereoisomers from high performance liquid chromatography separation on a permethylated β-cyclcodextrin stationary phase has been computed using classical molecular dynamics simulations with the explicit solvents water and acetonitrile. Comparison of estimated with experimental separation data reveals remarkable squared coefficients of correlation with R2=0.87 and a very high correlation RLOO2 . 0:72 using the leaveone-out cross-validation method and water as solvent. In particular, the approach presented shapes up as very robust in terms of the evaluated time range under consideration, reflecting well thermodynamic equilibria. These and further observations correlating with experimental results suggest the suitability of the underlying force fields and our multi-mode approach for the estimation of relative binding affinities for host–guest systems with unknown binding modes.
The reliability in measurement results obtained during environmental monitoring is crucial for the assessment and further planning of remediation efforts on the respective contaminated sites by the responsible authorities. A case study concerned with groundwater contaminated with perchloroethylene, trichloroethylene and 1,1,2-trichlorotrifluoroethane including their degradation products which involves private contract laboratories and an independent provider of quality assurance (QA) is presented. The experience gained with biannual monitoring campaigns over 14 years indicates that the selection of contractors on basis of accreditation status and successful performance in interlaboratory comparisons are not sufficient. Rather the auditing of the contractors by the QA provider prior to each campaign and the crosschecking of selected monitoring samples by the QA provider led to a lasting improvement of reliability in the contractors' measurement results. A mean deviation of 20% from the reference value determined by the QA provider for the crosschecked samples was reached.
Aim: The objective of the study was to provide conclusive evidence for the effect of particle size reduction as by milling on the extractable content of ethyl glucuronide (EtG) of hair samples. Methods: A number of real case hair samples and two pooled hair materials with EtG contents in the range of 1030 pg/mg were systematically compared with regard to the extraction yield of EtG after cutting to 23 mm length and pulverization with a ball mill. After the respective treatment the samples were submitted to aqueous extraction followed by quantification of EtG using HPLC-MS/MS. Results: It was unequivocally demonstrated that milling of hair samples prior to aqueous extraction significantly increases the extractable EtG content compared with cut hair. The effect ranged between 137 and 230% and was seen to occur regardless of the extent of pulverization. Cooling of samples was not necessary to prevent partial degradation of EtG during the grinding procedure. Conclusion: The options currently employed at choice in analytical practice (cutting or milling) were seen to significantly affect the extractable amount of EtG in hair. This is suspected to influence the degree of equivalence of quantification results obtained in different laboratories as well as their respective classification of a test subject's drinking behaviour on the basis of currently recommended cut-off values.
The title compound, {2-[(2-carbamoylethyl)amino]-3-methylpentanoic acid}, C9H18N2O3, is of interest with respect to its biological activity. It was formed during an addition reaction between acrylamide and the amino acid isoleucine. The crystal structure is a three-dimensional network built up by intermolecular N–H···O and O–H···N hydrogen bonds.